title: "Gintung Energy ASEC-205G6M Specs (205.0W, 33.58V Voc)"
url: https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-205g6m/
description: "CEC datasheet for Gintung Energy ASEC-205G6M: 205.0W STC, 33.58V Voc, 40-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# Gintung Energy ASEC-205G6M — CEC Solar Module Specifications

Manufacturer: [**Gintung Energy**](https://epri-peac.com/solar-equipment/brands/gintung-energy/) Registry: **CEC Verified Engineering Specification**

Gintung Energy ASEC-205G6M is a 205.0 W STC (181.5 W PTC) Multi-c-Si solar module ranking #20,980 of 21,677 CEC listings (below all-CEC median; higher than 3.0% of peers). It delivers 14.57% efficiency, 33.58 V Voc at 25 C, and 38.52 V cold Voc at -10 C (15 panels max per 600 V string).

- **STC Wattage** : 205.0 W

- **PTC Wattage** : 181.5 W

- **Voc @ 25C** : 33.58 V

- **Efficiency** : 14.57%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Gintung Energy ASEC-205G6M Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Gintung Energy ASEC-205G6M (Multi-c-Si) residential solar systems.

Homeowners evaluating Gintung Energy ASEC-205G6M need 30 panels for 6 kW or 40 panels (606 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 40 panels (606 sq ft). Under NEC 690.7(A), beta_Voc (-0.42%/C) pushes open-circuit voltage to 38.52 V at 14 F and 39.93 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

## Where Does Gintung Energy ASEC-205G6M Fall Across Listed CEC Models?

Comparison of Gintung Energy ASEC-205G6M (205.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

## What Dataset Percentiles Define Gintung Energy ASEC-205G6M?

Relative ranking of Gintung Energy ASEC-205G6M across nameplate watts, 88.5% PTC thermal ratio, and module aperture efficiency. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

## What Do the Dataset Ranks Show for Gintung Energy ASEC-205G6M?

Summary of Gintung Energy ASEC-205G6M output rank, 8 kW array size (40 panels), efficiency rating, and 600 V string limit.

Rank #20,980 / 21,677

### 205.0 W STC · Higher Than 3.0%

205.0 W STC (-180.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #20,326

### 14.57% Aperture Efficiency

Power density 145.7 W/m2 (5.34 percentage points below 19.91% CEC median). PTC/STC ratio: 88.5% (rank #21,133).

NEC 690.7 Limit

### 15 Panels Max @ -10 C (600 V)

Cold Voc reaches 38.52 V at -10 C (577.8 V string) and 39.93 V at -20 C (15 max).

 8 kW Reference Array

### 40 Panels = 8,200 W STC

Occupies 56.3 m2 (606 sq ft) producing 7,260 W PTC; NEC 690.8 OCPD floor is 13.43 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 33.58 * (1 + (-0.42/100) * (-10 - 25)) = 38.52 V | OCPD = 1.56 * 8.61 = 13.43 A

Inputs from CEC Modules.csv for Gintung Energy ASEC-205G6M: Voc=33.58 V, beta_Voc=-0.42%/C, Isc=8.61 A, STC=205.0 W, Area=1.407 m2.

**Result:** 15 panels max on 600 V (577.8 V); 40 panels for 8 kW (606 sq ft).

## What Are the Published CEC Specifications for Gintung Energy ASEC-205G6M?

Complete CEC test sheet for Gintung Energy ASEC-205G6M including Isc (8.61 A), Voc (33.58 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Gintung Energy ASEC-205G6M.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 205.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 181.5 W (88.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 33.58 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.61 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 25.87 V / 7.93 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.42 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 14.57% (1.407 m2) | Array roof footprint density |
| **Cell Count & Technology** | 54 cells (Multi-c-Si) | Monofacial backsheet |

## How Many Gintung Energy ASEC-205G6M Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Gintung Energy ASEC-205G6M.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 30 | 6.15 kW | 454 sq ft | $1,539 | $2,603 |
| **8 kW Class** | 40 | 8.2 kW | 606 sq ft | $2,052 | $3,470 |
| **10 kW Class** | 49 | 10.04 kW | 742 sq ft | $2,513 | $4,249 |

## Which Sibling Wattage & Trim Variants Belong to This Gintung Energy Series?

Related Gintung Energy power steps and black/silver trims consolidated into this Gintung Energy ASEC-205G6M series guide. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Sibling CEC listings grouped into the Gintung Energy ASEC-205G6M wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Gintung Energy ASEC-200G6M** | 200.0 W | 176.9 W | 33.03 V | 25.5 V | 14.21% |
| **Gintung Energy ASEC-205G6M** | 205.0 W | 181.5 W | 33.58 V | 25.87 V | 14.57% |
| **Gintung Energy ASEC-210G6M** | 210.0 W | 186.1 W | 33.61 V | 26.19 V | 14.93% |

## How Many Gintung Energy ASEC-205G6M Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Gintung Energy ASEC-205G6M (33.58 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=33.58V and beta_Voc=-0.42%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 39.93 V | 15 panels | 599.0 V | 25 panels |
| **-10 C (14 F)** | 38.52 V | 15 panels | 577.8 V | 25 panels |
| **0 C (32 F)** | 37.11 V | 16 panels | 593.8 V | 26 panels |
| **25 C (77 F STC)** | 33.58 V | 17 panels | 570.9 V | 29 panels |

## Which Cross-Brand Solar Modules Compare Closest to Gintung Energy ASEC-205G6M?

Four comparable CEC modules such as APOS Energy AP205 (205.0 W) for side-by-side solar quote checks. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**APOS Energy AP205**](https://epri-peac.com/solar-equipment/modules/apos-energy/apos-energy-ap205/) APOS Energy | 205.0 W | Tie (0 W) | 33.48 V | 13.67% | 88.9% |
| [**Guangdong Golden Glass Technologies GG205M2-27/1482x992**](https://epri-peac.com/solar-equipment/modules/guangdong-golden-glass-technologies/guangdong-golden-glass-technologies-gg205m2-27-1482x992/) Guangdong Golden Glass Technologies | 205.0 W | Tie (0 W) | 33.2 V | 13.94% | 89.9% |
| [**Hanwha Qcells (Qidong) Co Ltd SF190-27-M205**](https://epri-peac.com/solar-equipment/modules/hanwha-qcells-qidong-co-ltd/hanwha-qcells-qidong-co-ltd-sf190-27-m205/) Hanwha Qcells (Qidong) Co Ltd | 205.0 W | Tie (0 W) | 33.1 V | 13.72% | 88.9% |
| [**Hanwha Qcells (Qidong) Co Ltd SF190-27-M205B**](https://epri-peac.com/solar-equipment/modules/hanwha-qcells-qidong-co-ltd/hanwha-qcells-qidong-co-ltd-sf190-27-m205b/) Hanwha Qcells (Qidong) Co Ltd | 205.0 W | Tie (0 W) | 33.1 V | 13.72% | 88.9% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Gintung Energy ASEC-205G6M?

Evaluate Gintung Energy ASEC-205G6M (205.0 W STC, 33.58 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Gintung Energy ASEC-205G6M reaches 39.93 V per panel—exceeding 15 panels in series voids 600 V inverter warranties.
- Footprint constraint: 40 panels for an 8 kW build require 606 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 40 panels (606 sq ft).
- 2026 tax credit baseline: cash residential installs of Gintung Energy ASEC-205G6M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Gintung Energy ASEC-205G6M 8 kW Residential Fit

Needs 40 modules (606 sq ft) with a 15 A string OCPD, offsetting ~$2,052/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 15 panels (-10 C) or 15 panels (-20 C), or compare APOS Energy AP205.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 181.5 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Gintung Energy ASEC-205G6M by Gintung Energy grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is Gintung Energy ASEC-205G6M PTC wattage (181.5 W) lower than STC (205.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 181.5 W PTC (88.5% retention) across Gintung Energy ASEC-205G6M's 1.407 m2 aperture.

### Who should skip Gintung Energy ASEC-205G6M on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 40 Gintung Energy ASEC-205G6M panels (606 sq ft) leave unusable roof gaps vs. APOS Energy AP205.

### What is the 1,000 V commercial string limit for Gintung Energy ASEC-205G6M?

On 1,000 V commercial inverters at -10 C (38.52 V cold Voc), Gintung Energy ASEC-205G6M fits up to 25 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Gintung Energy ASEC-205G6M.

## Related Pages

Compare Gintung Energy equipment, APOS Energy AP205 specs, utility payback rates, and NEC string calculators alongside Gintung Energy ASEC-205G6M.

[All Gintung Energy Certified Solar Models](https://epri-peac.com/solar-equipment/brands/gintung-energy/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Gintung Energy

- [All Gintung Energy Specs](https://epri-peac.com/solar-equipment/brands/gintung-energy/)
- [Gintung Energy ASEC-325G6M](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-325g6m/)
- [Gintung Energy ASEC-325G6S](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-325g6s/)
- [Gintung Energy GTEC-325G6M](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-gtec-325g6m/)
- [Gintung Energy GTEC-325G6S](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-gtec-325g6s/)
- [Gintung Energy ASEC-310G6M](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-310g6m/)