title: "Gintung Energy ASEC-145G6S49 Specs (145.0W, 22.38V Voc)"
url: https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-145g6s49/
description: "CEC datasheet for Gintung Energy ASEC-145G6S49: 145.0W STC, 22.38V Voc, 56-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# Gintung Energy ASEC-145G6S49 — CEC Solar Module Specifications

Manufacturer: [**Gintung Energy**](https://epri-peac.com/solar-equipment/brands/gintung-energy/) Registry: **CEC Verified Engineering Specification**

Gintung Energy ASEC-145G6S49 is a 145.0 W STC (126.8 W PTC) Mono-c-Si solar module ranking #21,426 of 21,677 CEC listings (below all-CEC median; higher than 1.1% of peers). It delivers 14.7% efficiency, 22.38 V Voc at 25 C, and 25.07 V cold Voc at -10 C (23 panels max per 600 V string).

- **STC Wattage** : 145.0 W

- **PTC Wattage** : 126.8 W

- **Voc @ 25C** : 22.38 V

- **Efficiency** : 14.7%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Gintung Energy ASEC-145G6S49 Compare Against Peer CEC Listings?

Engineering position of Gintung Energy ASEC-145G6S49 (145.0 W STC) vs. Merlin Solar Technologies Inc FXS 145L-B across 5,889 CEC Mono-c-Si solar modules.

Ranking #21,426 across 21,677 CEC solar panels (below all-CEC median; higher than 1.1% of peers), Gintung Energy ASEC-145G6S49 operates as a compact residential or specialty off-grid module sitting 265.0 W below the 410.0 W Mono-c-Si median. Lower 22.38 V string voltage fits 23 panels in series at 14 F and pairs easily with microinverters. With typical 87.4% PTC-to-STC thermal output (126.8 W real-world rating), 56 panels occupy 594 sq ft and offset roughly $2,032/yr at average US rates (or $3,437/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

## Where Does Gintung Energy ASEC-145G6S49 Fall Across Listed CEC Models?

Plots Gintung Energy ASEC-145G6S49 at 145.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

## What Dataset Percentiles Define Gintung Energy ASEC-145G6S49?

Benchmarks Gintung Energy ASEC-145G6S49 on STC wattage, thermal PTC/STC retention, and 14.7 aperture conversion efficiency against CEC peers.

## What Do the Dataset Ranks Show for Gintung Energy ASEC-145G6S49?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Gintung Energy ASEC-145G6S49 by Gintung Energy.

Rank #21,426 / 21,677

### 145.0 W STC · Higher Than 1.1%

145.0 W STC (-240.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #20,155

### 14.7% Aperture Efficiency

Power density 147.1 W/m2 (5.21 percentage points below 19.91% CEC median). PTC/STC ratio: 87.4% (rank #21,562).

NEC 690.7 Limit

### 23 Panels Max @ -10 C (600 V)

Cold Voc reaches 25.07 V at -10 C (576.6 V string) and 25.83 V at -20 C (23 max).

 8 kW Reference Array

### 56 Panels = 8,120 W STC

Occupies 55.2 m2 (594 sq ft) producing 7,101 W PTC; NEC 690.8 OCPD floor is 13.48 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 22.38 * (1 + (-0.343/100) * (-10 - 25)) = 25.07 V | OCPD = 1.56 * 8.64 = 13.48 A

Inputs from CEC Modules.csv for Gintung Energy ASEC-145G6S49: Voc=22.38 V, beta_Voc=-0.343%/C, Isc=8.64 A, STC=145.0 W, Area=0.986 m2.

**Result:** 23 panels max on 600 V (576.6 V); 56 panels for 8 kW (594 sq ft).

## What Are the Published CEC Specifications for Gintung Energy ASEC-145G6S49?

Laboratory test ratings recorded for Gintung Energy ASEC-145G6S49 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Gintung Energy ASEC-145G6S49.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 145.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 126.8 W (87.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 22.38 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.64 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 17.68 V / 8.2 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.343 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 14.7% (0.986 m2) | Array roof footprint density |
| **Cell Count & Technology** | 36 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Gintung Energy ASEC-145G6S49 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (594 sq ft at 8 kW), and estimated Year-1 electric bill offset for Gintung Energy ASEC-145G6S49.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 42 | 6.09 kW | 446 sq ft | $1,524 | $2,577 |
| **8 kW Class** | 56 | 8.12 kW | 594 sq ft | $2,032 | $3,437 |
| **10 kW Class** | 69 | 10.01 kW | 732 sq ft | $2,505 | $4,236 |

## How Many Gintung Energy ASEC-145G6S49 Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Gintung Energy ASEC-145G6S49 (beta_Voc -0.343%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=22.38V and beta_Voc=-0.343%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 25.83 V | 23 panels | 594.1 V | 38 panels |
| **-10 C (14 F)** | 25.07 V | 23 panels | 576.6 V | 39 panels |
| **0 C (32 F)** | 24.3 V | 24 panels | 583.2 V | 41 panels |
| **25 C (77 F STC)** | 22.38 V | 26 panels | 581.9 V | 44 panels |

## Which Cross-Brand Solar Modules Compare Closest to Gintung Energy ASEC-145G6S49?

Closest cross-brand CEC competitors to Gintung Energy ASEC-145G6S49 matched near 145.0 W STC and 22.38 V Voc, led by Merlin Solar Technologies Inc FXS 145L-B.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Merlin Solar Technologies Inc FXS 145L-B**](https://epri-peac.com/solar-equipment/modules/merlin-solar-technologies-inc/merlin-solar-technologies-inc-fxs-145l-b/) Merlin Solar Technologies Inc | 145.0 W | Tie (0 W) | 22.67 V | 13.06% | 88.3% |
| [**Merlin Solar Technologies Inc FXS 145S-B**](https://epri-peac.com/solar-equipment/modules/merlin-solar-technologies-inc/merlin-solar-technologies-inc-fxs-145s-b/) Merlin Solar Technologies Inc | 145.0 W | Tie (0 W) | 22.67 V | 13.81% | 88.4% |
| [**APOS Energy AS140**](https://epri-peac.com/solar-equipment/modules/apos-energy/apos-energy-as140/) APOS Energy | 140.0 W | -5.0 W | 22.33 V | 13.69% | 89.6% |
| [**Centrosolar America DP36 140**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-dp36-140/) Centrosolar America | 140.0 W | -5.0 W | 22.15 V | 13.85% | 88.4% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Gintung Energy ASEC-145G6S49?

Evaluate Gintung Energy ASEC-145G6S49 (145.0 W STC, 22.38 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Gintung Energy ASEC-145G6S49 reaches 25.83 V per panel—exceeding 23 panels in series voids 600 V inverter warranties.
- Footprint constraint: 56 panels for an 8 kW build require 594 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 56 panels (594 sq ft).
- 2026 tax credit baseline: cash residential installs of Gintung Energy ASEC-145G6S49 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Gintung Energy ASEC-145G6S49 8 kW Residential Fit

Needs 56 modules (594 sq ft) with a 15 A string OCPD, offsetting ~$2,032/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 23 panels (-10 C) or 23 panels (-20 C), or compare Merlin Solar Technologies Inc FXS 145L-B.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 126.8 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Gintung Energy ASEC-145G6S49 by Gintung Energy grounded in CEC test data and NEC 690.7/690.8 limits.

### How many Gintung Energy ASEC-145G6S49 panels fit on a 600 V winter solar string?

At -10 C (14 F), Gintung Energy ASEC-145G6S49 cold Voc rises from 22.38 V to 25.07 V (beta_Voc -0.343%/C), capping a 600 V string at 23 panels (576.6 V).

### How much roof area does an 8 kW array of Gintung Energy ASEC-145G6S49 need?

An 8 kW DC system uses 56 Gintung Energy ASEC-145G6S49 modules (8,120 W STC / 7,101 W PTC), covering roughly 594 sq ft and saving ~$2,032/yr at 18.54 c/kWh.

### How does Gintung Energy ASEC-145G6S49 compare against Merlin Solar Technologies Inc FXS 145L-B?

Gintung Energy ASEC-145G6S49 outputs 145.0 W STC (22.38 V Voc, rank #21,426 of 21,677), while Merlin Solar Technologies Inc FXS 145L-B delivers 145.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare Gintung Energy equipment, Merlin Solar Technologies Inc FXS 145L-B specs, utility payback rates, and NEC string calculators alongside Gintung Energy ASEC-145G6S49.

[All Gintung Energy Certified Solar Models](https://epri-peac.com/solar-equipment/brands/gintung-energy/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Gintung Energy

- [All Gintung Energy Specs](https://epri-peac.com/solar-equipment/brands/gintung-energy/)
- [Gintung Energy ASEC-325G6M](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-325g6m/)
- [Gintung Energy ASEC-325G6S](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-325g6s/)
- [Gintung Energy GTEC-325G6M](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-gtec-325g6m/)
- [Gintung Energy GTEC-325G6S](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-gtec-325g6s/)
- [Gintung Energy ASEC-310G6M](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-310g6m/)