title: "Gintung Energy ASEC-145G6M49 Specs (145.0W, 22.32V Voc)"
url: https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-145g6m49/
description: "CEC datasheet for Gintung Energy ASEC-145G6M49: 145.0W STC, 22.32V Voc, 56-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# Gintung Energy ASEC-145G6M49 — CEC Solar Module Specifications

Manufacturer: [**Gintung Energy**](https://epri-peac.com/solar-equipment/brands/gintung-energy/) Registry: **CEC Verified Engineering Specification**

Gintung Energy ASEC-145G6M49 is a 145.0 W STC (127.4 W PTC) Multi-c-Si solar module ranking #21,426 of 21,677 CEC listings (below all-CEC median; higher than 1.1% of peers). It delivers 14.7% efficiency, 22.32 V Voc at 25 C, and 25.0 V cold Voc at -10 C (24 panels max per 600 V string).

- **STC Wattage** : 145.0 W

- **PTC Wattage** : 127.4 W

- **Voc @ 25C** : 22.32 V

- **Efficiency** : 14.7%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Gintung Energy ASEC-145G6M49 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Gintung Energy ASEC-145G6M49 (Multi-c-Si) residential solar systems.

Homeowners evaluating Gintung Energy ASEC-145G6M49 need 42 panels for 6 kW or 56 panels (594 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 56 panels (594 sq ft). Under NEC 690.7(A), beta_Voc (-0.343%/C) pushes open-circuit voltage to 25.0 V at 14 F and 25.77 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

## Where Does Gintung Energy ASEC-145G6M49 Fall Across Listed CEC Models?

Comparison of Gintung Energy ASEC-145G6M49 (145.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

## What Dataset Percentiles Define Gintung Energy ASEC-145G6M49?

Relative ranking of Gintung Energy ASEC-145G6M49 across nameplate watts, 87.9% PTC thermal ratio, and module aperture efficiency. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

## What Do the Dataset Ranks Show for Gintung Energy ASEC-145G6M49?

Summary of Gintung Energy ASEC-145G6M49 output rank, 8 kW array size (56 panels), efficiency rating, and 600 V string limit.

Rank #21,426 / 21,677

### 145.0 W STC · Higher Than 1.1%

145.0 W STC (-240.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #20,155

### 14.7% Aperture Efficiency

Power density 147.1 W/m2 (5.21 percentage points below 19.91% CEC median). PTC/STC ratio: 87.9% (rank #21,435).

NEC 690.7 Limit

### 24 Panels Max @ -10 C (600 V)

Cold Voc reaches 25.0 V at -10 C (600.0 V string) and 25.77 V at -20 C (23 max).

 8 kW Reference Array

### 56 Panels = 8,120 W STC

Occupies 55.2 m2 (594 sq ft) producing 7,134 W PTC; NEC 690.8 OCPD floor is 13.51 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 22.32 * (1 + (-0.343/100) * (-10 - 25)) = 25.0 V | OCPD = 1.56 * 8.66 = 13.51 A

Inputs from CEC Modules.csv for Gintung Energy ASEC-145G6M49: Voc=22.32 V, beta_Voc=-0.343%/C, Isc=8.66 A, STC=145.0 W, Area=0.986 m2.

**Result:** 24 panels max on 600 V (600.0 V); 56 panels for 8 kW (594 sq ft).

## What Are the Published CEC Specifications for Gintung Energy ASEC-145G6M49?

Complete CEC test sheet for Gintung Energy ASEC-145G6M49 including Isc (8.66 A), Voc (22.32 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Gintung Energy ASEC-145G6M49.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 145.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 127.4 W (87.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 22.32 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.66 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 17.81 V / 8.14 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.343 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 14.7% (0.986 m2) | Array roof footprint density |
| **Cell Count & Technology** | 36 cells (Multi-c-Si) | Monofacial backsheet |

## How Many Gintung Energy ASEC-145G6M49 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Gintung Energy ASEC-145G6M49.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 42 | 6.09 kW | 446 sq ft | $1,524 | $2,577 |
| **8 kW Class** | 56 | 8.12 kW | 594 sq ft | $2,032 | $3,437 |
| **10 kW Class** | 69 | 10.01 kW | 732 sq ft | $2,505 | $4,236 |

## How Many Gintung Energy ASEC-145G6M49 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Gintung Energy ASEC-145G6M49 (22.32 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=22.32V and beta_Voc=-0.343%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 25.77 V | 23 panels | 592.7 V | 38 panels |
| **-10 C (14 F)** | 25.0 V | 24 panels | 600.0 V | 40 panels |
| **0 C (32 F)** | 24.23 V | 24 panels | 581.5 V | 41 panels |
| **25 C (77 F STC)** | 22.32 V | 26 panels | 580.3 V | 44 panels |

## Which Cross-Brand Solar Modules Compare Closest to Gintung Energy ASEC-145G6M49?

Four comparable CEC modules such as Merlin Solar Technologies Inc FXS 145L-B (145.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Merlin Solar Technologies Inc FXS 145L-B**](https://epri-peac.com/solar-equipment/modules/merlin-solar-technologies-inc/merlin-solar-technologies-inc-fxs-145l-b/) Merlin Solar Technologies Inc | 145.0 W | Tie (0 W) | 22.67 V | 13.06% | 88.3% |
| [**Merlin Solar Technologies Inc FXS 145S-B**](https://epri-peac.com/solar-equipment/modules/merlin-solar-technologies-inc/merlin-solar-technologies-inc-fxs-145s-b/) Merlin Solar Technologies Inc | 145.0 W | Tie (0 W) | 22.67 V | 13.81% | 88.4% |
| [**APOS Energy AS140**](https://epri-peac.com/solar-equipment/modules/apos-energy/apos-energy-as140/) APOS Energy | 140.0 W | -5.0 W | 22.33 V | 13.69% | 89.6% |
| [**Centrosolar America DP36 140**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-dp36-140/) Centrosolar America | 140.0 W | -5.0 W | 22.15 V | 13.85% | 88.4% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Gintung Energy ASEC-145G6M49?

Evaluate Gintung Energy ASEC-145G6M49 (145.0 W STC, 22.32 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Gintung Energy ASEC-145G6M49 reaches 25.77 V per panel—exceeding 23 panels in series voids 600 V inverter warranties.
- Footprint constraint: 56 panels for an 8 kW build require 594 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 56 panels (594 sq ft).
- 2026 tax credit baseline: cash residential installs of Gintung Energy ASEC-145G6M49 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Gintung Energy ASEC-145G6M49 8 kW Residential Fit

Needs 56 modules (594 sq ft) with a 15 A string OCPD, offsetting ~$2,032/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 24 panels (-10 C) or 23 panels (-20 C), or compare Merlin Solar Technologies Inc FXS 145L-B.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 127.4 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Gintung Energy ASEC-145G6M49 by Gintung Energy grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is Gintung Energy ASEC-145G6M49 PTC wattage (127.4 W) lower than STC (145.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 127.4 W PTC (87.9% retention) across Gintung Energy ASEC-145G6M49's 0.986 m2 aperture.

### Who should skip Gintung Energy ASEC-145G6M49 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 56 Gintung Energy ASEC-145G6M49 panels (594 sq ft) leave unusable roof gaps vs. Merlin Solar Technologies Inc FXS 145L-B.

### What is the 1,000 V commercial string limit for Gintung Energy ASEC-145G6M49?

On 1,000 V commercial inverters at -10 C (25.0 V cold Voc), Gintung Energy ASEC-145G6M49 fits up to 40 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Gintung Energy ASEC-145G6M49.

## Related Pages

Compare Gintung Energy equipment, Merlin Solar Technologies Inc FXS 145L-B specs, utility payback rates, and NEC string calculators alongside Gintung Energy ASEC-145G6M49.

[All Gintung Energy Certified Solar Models](https://epri-peac.com/solar-equipment/brands/gintung-energy/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Gintung Energy

- [All Gintung Energy Specs](https://epri-peac.com/solar-equipment/brands/gintung-energy/)
- [Gintung Energy ASEC-325G6M](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-325g6m/)
- [Gintung Energy ASEC-325G6S](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-325g6s/)
- [Gintung Energy GTEC-325G6M](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-gtec-325g6m/)
- [Gintung Energy GTEC-325G6S](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-gtec-325g6s/)
- [Gintung Energy ASEC-310G6M](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-310g6m/)