title: "GermanSolar USA GSM6-60-300W Specs (300.0W, 39.82V Voc)"
url: https://epri-peac.com/solar-equipment/modules/germansolar-usa/germansolar-usa-gsm6-60-300w/
description: "CEC datasheet for GermanSolar USA GSM6-60-300W: 300.0W STC, 39.82V Voc, 27-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# GermanSolar USA GSM6-60-300W — CEC Solar Module Specifications

Manufacturer: [**GermanSolar USA**](https://epri-peac.com/solar-equipment/brands/germansolar-usa/) Registry: **CEC Verified Engineering Specification**

GermanSolar USA GSM6-60-300W is a 300.0 W STC (271.5 W PTC) Mono-c-Si solar module ranking #16,498 of 21,677 CEC listings (below all-CEC median; higher than 22.1% of peers). It delivers 18.24% efficiency, 39.82 V Voc at 25 C, and 44.57 V cold Voc at -10 C (13 panels max per 600 V string).

- **STC Wattage** : 300.0 W

- **PTC Wattage** : 271.5 W

- **Voc @ 25C** : 39.82 V

- **Efficiency** : 18.24%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does GermanSolar USA GSM6-60-300W Compare Against Peer CEC Listings?

How GermanSolar USA GermanSolar USA GSM6-60-300W handles rooftop heat (271.5 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, GermanSolar USA GSM6-60-300W exhibits 9.78 A short-circuit current, requiring a 15.26 A (156%) conductor rating and 20 A OCPD under NEC 690.8. Ranked #16,498 of 21,677 (110.0 W below the 410.0 W Mono-c-Si median), this compact residential or specialty off-grid module covers 44.4 m2 for an 8 kW system (34 panels for 10 kW). Lower 39.82 V string voltage fits 13 panels in series at 14 F and pairs easily with microinverters.

## Where Does GermanSolar USA GSM6-60-300W Fall Across Listed CEC Models?

Where GermanSolar USA GSM6-60-300W (300.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define GermanSolar USA GSM6-60-300W?

Percentile placement of GermanSolar USA GSM6-60-300W across power density (182.4 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for GermanSolar USA GSM6-60-300W?

Four critical engineering numbers homeowners and solar installers check first when reviewing GermanSolar USA GSM6-60-300W specifications. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Rank #16,498 / 21,677

### 300.0 W STC · Higher Than 22.1%

300.0 W STC (-85.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #14,769

### 18.24% Aperture Efficiency

Power density 182.4 W/m2 (1.67 percentage points below 19.91% CEC median). PTC/STC ratio: 90.5% (rank #17,786).

NEC 690.7 Limit

### 13 Panels Max @ -10 C (600 V)

Cold Voc reaches 44.57 V at -10 C (579.4 V string) and 45.93 V at -20 C (13 max).

 8 kW Reference Array

### 27 Panels = 8,100 W STC

Occupies 44.4 m2 (478 sq ft) producing 7,330 W PTC; NEC 690.8 OCPD floor is 15.26 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 39.82 * (1 + (-0.341/100) * (-10 - 25)) = 44.57 V | OCPD = 1.56 * 9.78 = 15.26 A

Inputs from CEC Modules.csv for GermanSolar USA GSM6-60-300W: Voc=39.82 V, beta_Voc=-0.341%/C, Isc=9.78 A, STC=300.0 W, Area=1.645 m2.

**Result:** 13 panels max on 600 V (579.4 V); 27 panels for 8 kW (478 sq ft).

## What Are the Published CEC Specifications for GermanSolar USA GSM6-60-300W?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for GermanSolar USA GSM6-60-300W.

Official California Energy Commission (NREL SAM) test parameters for GermanSolar USA GSM6-60-300W.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 300.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 271.5 W (90.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 39.82 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 9.78 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 32.25 V / 9.33 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.341 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 18.24% (1.645 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Mono-c-Si) | Monofacial backsheet |

## How Many GermanSolar USA GSM6-60-300W Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using GermanSolar USA GSM6-60-300W (300.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 20 | 6.0 kW | 354 sq ft | $1,502 | $2,539 |
| **8 kW Class** | 27 | 8.1 kW | 478 sq ft | $2,027 | $3,428 |
| **10 kW Class** | 34 | 10.2 kW | 602 sq ft | $2,553 | $4,317 |

## How Many GermanSolar USA GSM6-60-300W Modules Fit in a Cold-Weather String?

Maximum series module counts for GermanSolar USA GSM6-60-300W from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=39.82V and beta_Voc=-0.341%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 45.93 V | 13 panels | 597.1 V | 21 panels |
| **-10 C (14 F)** | 44.57 V | 13 panels | 579.4 V | 22 panels |
| **0 C (32 F)** | 43.21 V | 13 panels | 561.7 V | 23 panels |
| **25 C (77 F STC)** | 39.82 V | 15 panels | 597.3 V | 25 panels |

## Which Cross-Brand Solar Modules Compare Closest to GermanSolar USA GSM6-60-300W?

Alternative CEC solar modules from competing brands near GermanSolar USA GSM6-60-300W (300.0 W), including FreeVolt PV-GRAF-60M6-300/M. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**FreeVolt PV-GRAF-60M6-300/M**](https://epri-peac.com/solar-equipment/modules/freevolt/freevolt-pv-graf-60m6-300-m/) FreeVolt | 300.0 W | Tie (0 W) | 39.6 V | 18.29% | 91.1% |
| [**Enphase Energy Inc XACM-IQ7-LR6-60PB-300M**](https://epri-peac.com/solar-equipment/modules/enphase-energy-inc/enphase-energy-inc-xacm-iq7-lr6-60pb-300m/) Enphase Energy Inc | 300.0 W | Tie (0 W) | 40.1 V | 18.99% | 91.1% |
| [**CertainTeed CT300M10-03**](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-ct300m10-03/) CertainTeed | 300.0 W | Tie (0 W) | 40.3 V | 18.55% | 92.4% |
| [**CertainTeed CT300M11-03**](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-ct300m11-03/) CertainTeed | 300.0 W | Tie (0 W) | 40.3 V | 18.68% | 92.1% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for GermanSolar USA GSM6-60-300W?

Evaluate GermanSolar USA GSM6-60-300W (300.0 W STC, 39.82 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), GermanSolar USA GSM6-60-300W reaches 45.93 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 27 panels for an 8 kW build require 478 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 27 panels (478 sq ft).
- 2026 tax credit baseline: cash residential installs of GermanSolar USA GSM6-60-300W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### GermanSolar USA GSM6-60-300W 8 kW Residential Fit

Needs 27 modules (478 sq ft) with a 20 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare FreeVolt PV-GRAF-60M6-300/M.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 271.5 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for GermanSolar USA GSM6-60-300W by GermanSolar USA grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is GermanSolar USA GSM6-60-300W PTC wattage (271.5 W) lower than STC (300.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 271.5 W PTC (90.5% retention) across GermanSolar USA GSM6-60-300W's 1.645 m2 aperture.

### Who should skip GermanSolar USA GSM6-60-300W on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 27 GermanSolar USA GSM6-60-300W panels (478 sq ft) leave unusable roof gaps vs. FreeVolt PV-GRAF-60M6-300/M.

### What is the 1,000 V commercial string limit for GermanSolar USA GSM6-60-300W?

On 1,000 V commercial inverters at -10 C (44.57 V cold Voc), GermanSolar USA GSM6-60-300W fits up to 22 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting GermanSolar USA GSM6-60-300W.

## Related Pages

Compare GermanSolar USA equipment, FreeVolt PV-GRAF-60M6-300/M specs, utility payback rates, and NEC string calculators alongside GermanSolar USA GSM6-60-300W.

[All GermanSolar USA Certified Solar Models](https://epri-peac.com/solar-equipment/brands/germansolar-usa/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From GermanSolar USA

- [All GermanSolar USA Specs](https://epri-peac.com/solar-equipment/brands/germansolar-usa/)
- [GermanSolar USA GSM6-72-330W](https://epri-peac.com/solar-equipment/modules/germansolar-usa/germansolar-usa-gsm6-72-330w/)
- [GermanSolar USA GSP6-72-325W](https://epri-peac.com/solar-equipment/modules/germansolar-usa/germansolar-usa-gsp6-72-325w/)
- [GermanSolar USA GSM6-72-315W](https://epri-peac.com/solar-equipment/modules/germansolar-usa/germansolar-usa-gsm6-72-315w/)
- [GermanSolar USA GSP6-72-310W](https://epri-peac.com/solar-equipment/modules/germansolar-usa/germansolar-usa-gsp6-72-310w/)
- [GermanSolar USA GSM6-60-285W](https://epri-peac.com/solar-equipment/modules/germansolar-usa/germansolar-usa-gsm6-60-285w/)