title: "GermanSolar USA GSM6-60-265W Specs (265.0W, 38.3V Voc)"
url: https://epri-peac.com/solar-equipment/modules/germansolar-usa/germansolar-usa-gsm6-60-265w/
description: "CEC datasheet for GermanSolar USA GSM6-60-265W: 265.0W STC, 38.3V Voc, 31-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# GermanSolar USA GSM6-60-265W — CEC Solar Module Specifications

Manufacturer: [**GermanSolar USA**](https://epri-peac.com/solar-equipment/brands/germansolar-usa/) Registry: **CEC Verified Engineering Specification**

GermanSolar USA GSM6-60-265W is a 265.0 W STC (239.9 W PTC) Mono-c-Si solar module ranking #18,880 of 21,677 CEC listings (below all-CEC median; higher than 11.7% of peers). It delivers 16.29% efficiency, 38.3 V Voc at 25 C, and 43.1 V cold Voc at -10 C (13 panels max per 600 V string).

- **STC Wattage** : 265.0 W

- **PTC Wattage** : 239.9 W

- **Voc @ 25C** : 38.3 V

- **Efficiency** : 16.29%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does GermanSolar USA GSM6-60-265W Compare Against Peer CEC Listings?

Solar engineering breakdown for GermanSolar USA GSM6-60-265W: PTC thermal retention, roof footprint, and cold Voc string bounds. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Across 5,889 Mono-c-Si listings from GermanSolar USA and peers, GermanSolar USA GSM6-60-265W stands 145.0 W below the 410.0 W Mono-c-Si median and typical 90.5% PTC-to-STC thermal output (239.9 W real-world rating). Sizing 6 kW (23 panels) to 10 kW (38 panels) yields $1,524-$2,520/yr in baseline US bill offset. Lower 38.3 V string voltage fits 13 panels in series at 14 F and pairs easily with microinverters.

## Where Does GermanSolar USA GSM6-60-265W Fall Across Listed CEC Models?

Distribution marker showing GermanSolar USA GSM6-60-265W (265.0 W) relative to the 385.0 W all-CEC solar panel median. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

## What Dataset Percentiles Define GermanSolar USA GSM6-60-265W?

Dataset percentiles tracking GermanSolar USA GSM6-60-265W power output, thermal retention ratio, and aperture efficiency against 21,677 models. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

## What Do the Dataset Ranks Show for GermanSolar USA GSM6-60-265W?

Benchmark highlights for GermanSolar USA GSM6-60-265W covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Rank #18,880 / 21,677

### 265.0 W STC · Higher Than 11.7%

265.0 W STC (-120.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #17,670

### 16.29% Aperture Efficiency

Power density 162.9 W/m2 (3.62 percentage points below 19.91% CEC median). PTC/STC ratio: 90.5% (rank #17,786).

NEC 690.7 Limit

### 13 Panels Max @ -10 C (600 V)

Cold Voc reaches 43.1 V at -10 C (560.3 V string) and 44.47 V at -20 C (13 max).

 8 kW Reference Array

### 31 Panels = 8,215 W STC

Occupies 50.4 m2 (543 sq ft) producing 7,437 W PTC; NEC 690.8 OCPD floor is 14.29 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 38.3 * (1 + (-0.358/100) * (-10 - 25)) = 43.1 V | OCPD = 1.56 * 9.16 = 14.29 A

Inputs from CEC Modules.csv for GermanSolar USA GSM6-60-265W: Voc=38.3 V, beta_Voc=-0.358%/C, Isc=9.16 A, STC=265.0 W, Area=1.627 m2.

**Result:** 13 panels max on 600 V (560.3 V); 31 panels for 8 kW (543 sq ft).

## What Are the Published CEC Specifications for GermanSolar USA GSM6-60-265W?

Official CEC datasheet figures for GermanSolar USA GSM6-60-265W (Mono-c-Si) used in utility interconnection and permit reviews. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Official California Energy Commission (NREL SAM) test parameters for GermanSolar USA GSM6-60-265W.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 265.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 239.9 W (90.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 38.3 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 9.16 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 30.95 V / 8.56 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.358 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 16.29% (1.627 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Mono-c-Si) | Monofacial backsheet |

## How Many GermanSolar USA GSM6-60-265W Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many GermanSolar USA GSM6-60-265W modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 23 | 6.09 kW | 403 sq ft | $1,524 | $2,577 |
| **8 kW Class** | 31 | 8.21 kW | 543 sq ft | $2,055 | $3,475 |
| **10 kW Class** | 38 | 10.07 kW | 665 sq ft | $2,520 | $4,262 |

## Which Sibling Wattage & Trim Variants Belong to This GermanSolar USA Series?

Consolidated GermanSolar USA wattage variants sharing the GermanSolar USA GSM6-60-265W mechanical and cell layout. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Sibling CEC listings grouped into the GermanSolar USA GSM6-60-265W wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **GermanSolar USA GSM6-60-260W** | 260.0 W | 235.3 W | 38.1 V | 30.7 V | 15.98% |
| **GermanSolar USA GSM6-60-265W** | 265.0 W | 239.9 W | 38.3 V | 30.95 V | 16.29% |
| **GermanSolar USA GSM6-60-270W** | 270.0 W | 242.1 W | 38.63 V | 30.72 V | 16.6% |

## How Many GermanSolar USA GSM6-60-265W Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on GermanSolar USA GSM6-60-265W (43.1 V at 14 F).

Computed from Voc=38.3V and beta_Voc=-0.358%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 44.47 V | 13 panels | 578.1 V | 22 panels |
| **-10 C (14 F)** | 43.1 V | 13 panels | 560.3 V | 23 panels |
| **0 C (32 F)** | 41.73 V | 14 panels | 584.2 V | 23 panels |
| **25 C (77 F STC)** | 38.3 V | 15 panels | 574.5 V | 26 panels |

## Which Cross-Brand Solar Modules Compare Closest to GermanSolar USA GSM6-60-265W?

Competing CEC solar panels closest to GermanSolar USA GSM6-60-265W in nameplate wattage and Voc, starting with Centrosolar America CP60 265-C1.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Centrosolar America CP60 265-C1**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-cp60-265-c1/) Centrosolar America | 265.0 W | Tie (0 W) | 38.3 V | 16.29% | 90.4% |
| [**Centrosolar America EM60 265BB**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-em60-265bb/) Centrosolar America | 265.0 W | Tie (0 W) | 38.29 V | 16.45% | 91.0% |
| [**Centrosolar America EP60 265BW**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-ep60-265bw/) Centrosolar America | 265.0 W | Tie (0 W) | 38.29 V | 16.45% | 91.2% |
| [**Centrosolar America EP60 265SW**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-ep60-265sw/) Centrosolar America | 265.0 W | Tie (0 W) | 38.29 V | 16.45% | 91.2% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for GermanSolar USA GSM6-60-265W?

Evaluate GermanSolar USA GSM6-60-265W (265.0 W STC, 38.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), GermanSolar USA GSM6-60-265W reaches 44.47 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 31 panels for an 8 kW build require 543 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 31 panels (543 sq ft).
- 2026 tax credit baseline: cash residential installs of GermanSolar USA GSM6-60-265W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### GermanSolar USA GSM6-60-265W 8 kW Residential Fit

Needs 31 modules (543 sq ft) with a 15 A string OCPD, offsetting ~$2,055/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Centrosolar America CP60 265-C1.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 239.9 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for GermanSolar USA GSM6-60-265W by GermanSolar USA grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for GermanSolar USA GSM6-60-265W?

Multiplying GermanSolar USA GSM6-60-265W's 9.16 A short-circuit current by 1.56 equals 14.29 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

### Can GermanSolar USA GSM6-60-265W pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 43.1 V cold Voc at 14 F and handles 9.16 A Isc; string inverters cap GermanSolar USA GSM6-60-265W at 13 panels on 600 V.

### Is GermanSolar USA GSM6-60-265W eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of GermanSolar USA GSM6-60-265W rely on utility bill offset (~$2,055/yr at 8 kW) rather than 25D.

## Related Pages

Compare GermanSolar USA equipment, Centrosolar America CP60 265-C1 specs, utility payback rates, and NEC string calculators alongside GermanSolar USA GSM6-60-265W.

[All GermanSolar USA Certified Solar Models](https://epri-peac.com/solar-equipment/brands/germansolar-usa/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From GermanSolar USA

- [All GermanSolar USA Specs](https://epri-peac.com/solar-equipment/brands/germansolar-usa/)
- [GermanSolar USA GSM6-72-330W](https://epri-peac.com/solar-equipment/modules/germansolar-usa/germansolar-usa-gsm6-72-330w/)
- [GermanSolar USA GSP6-72-325W](https://epri-peac.com/solar-equipment/modules/germansolar-usa/germansolar-usa-gsp6-72-325w/)
- [GermanSolar USA GSM6-72-315W](https://epri-peac.com/solar-equipment/modules/germansolar-usa/germansolar-usa-gsm6-72-315w/)
- [GermanSolar USA GSP6-72-310W](https://epri-peac.com/solar-equipment/modules/germansolar-usa/germansolar-usa-gsp6-72-310w/)
- [GermanSolar USA GSM6-60-300W](https://epri-peac.com/solar-equipment/modules/germansolar-usa/germansolar-usa-gsm6-60-300w/)