title: "GCL System Integration Technology Specs (315.0W, 40.1V Voc)"
url: https://epri-peac.com/solar-equipment/modules/gcl-system-integration-technology-co-ltd/gcl-system-integration-technology-co-ltd-gcl-m6-60315/
description: "CEC datasheet for GCL System Integration Technology Co Ltd GCL-M6/60315: 315.0W STC, 40.1V Voc, 26-panel 8kW sizing, and NEC 690.7 limits."
---

CEC PV Module

# GCL System Integration Technology Co Ltd GCL-M6/60315 — CEC Solar Module Specifications

Manufacturer: [**GCL System Integration Technology Co Ltd**](https://epri-peac.com/solar-equipment/brands/gcl-system-integration-technology-co-ltd/) Registry: **CEC Verified Engineering Specification**

GCL System Integration Technology Co Ltd GCL-M6/60315 is a 315.0 W STC (287.6 W PTC) Mono-c-Si solar module ranking #15,387 of 21,677 CEC listings (below all-CEC median; higher than 27.3% of peers). It delivers 19.33% efficiency, 40.1 V Voc at 25 C, and 44.23 V cold Voc at -10 C (13 panels max per 600 V string).

- **STC Wattage** : 315.0 W

- **PTC Wattage** : 287.6 W

- **Voc @ 25C** : 40.1 V

- **Efficiency** : 19.33%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does GCL System Integration Technology Co Ltd GCL-M6/60315 Compare Against Peer CEC Listings?

How GCL System Integration Technology Co Ltd GCL System Integration Technology Co Ltd GCL-M6/60315 handles rooftop heat (287.6 W PTC), 8 kW sizing, and cold winter string voltage.

GCL System Integration Technology Co Ltd builds the GCL System Integration Technology Co Ltd GCL-M6/60315 (Mono-c-Si) as a compact residential or specialty off-grid module delivering 193.3 W/m2 (0.58 percentage points below 19.91% CEC median). Compared against AXITEC AC-315MH/120S (315.0 W), this model holds typical 91.3% PTC-to-STC thermal output (287.6 W real-world rating). Mid-range 40.1 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F, while NEC 690.8 sets a 15.66 A overcurrent floor served by a 20 A breaker.

## Where Does GCL System Integration Technology Co Ltd GCL-M6/60315 Fall Across Listed CEC Models?

Where GCL System Integration Technology Co Ltd GCL-M6/60315 (315.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define GCL System Integration Technology Co Ltd GCL-M6/60315?

Percentile placement of GCL System Integration Technology Co Ltd GCL-M6/60315 across power density (193.3 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for GCL System Integration Technology Co Ltd GCL-M6/60315?

Four critical engineering numbers homeowners and solar installers check first when reviewing GCL System Integration Technology Co Ltd GCL-M6/60315 specifications.

Rank #15,387 / 21,677

### 315.0 W STC · Higher Than 27.3%

315.0 W STC (-70.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #12,633

### 19.33% Aperture Efficiency

Power density 193.3 W/m2 (0.58 percentage points below 19.91% CEC median). PTC/STC ratio: 91.3% (rank #16,023).

NEC 690.7 Limit

### 13 Panels Max @ -10 C (600 V)

Cold Voc reaches 44.23 V at -10 C (575.0 V string) and 45.41 V at -20 C (13 max).

 8 kW Reference Array

### 26 Panels = 8,190 W STC

Occupies 42.4 m2 (456 sq ft) producing 7,478 W PTC; NEC 690.8 OCPD floor is 15.66 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 40.1 * (1 + (-0.294/100) * (-10 - 25)) = 44.23 V | OCPD = 1.56 * 10.04 = 15.66 A

Inputs from CEC Modules.csv for GCL System Integration Technology Co Ltd GCL-M6/60315: Voc=40.1 V, beta_Voc=-0.294%/C, Isc=10.04 A, STC=315.0 W, Area=1.63 m2.

**Result:** 13 panels max on 600 V (575.0 V); 26 panels for 8 kW (456 sq ft).

## What Are the Published CEC Specifications for GCL System Integration Technology Co Ltd GCL-M6/60315?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for GCL System Integration Technology Co Ltd GCL-M6/60315.

Official California Energy Commission (NREL SAM) test parameters for GCL System Integration Technology Co Ltd GCL-M6/60315.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 315.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 287.6 W (91.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 40.1 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 10.04 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 33.0 V / 9.55 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.294 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 19.33% (1.63 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Mono-c-Si) | Monofacial backsheet |

## How Many GCL System Integration Technology Co Ltd GCL-M6/60315 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using GCL System Integration Technology Co Ltd GCL-M6/60315 (315.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 20 | 6.3 kW | 351 sq ft | $1,577 | $2,666 |
| **8 kW Class** | 26 | 8.19 kW | 456 sq ft | $2,050 | $3,466 |
| **10 kW Class** | 32 | 10.08 kW | 561 sq ft | $2,523 | $4,266 |

## How Many GCL System Integration Technology Co Ltd GCL-M6/60315 Modules Fit in a Cold-Weather String?

Maximum series module counts for GCL System Integration Technology Co Ltd GCL-M6/60315 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=40.1V and beta_Voc=-0.294%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 45.41 V | 13 panels | 590.3 V | 22 panels |
| **-10 C (14 F)** | 44.23 V | 13 panels | 575.0 V | 22 panels |
| **0 C (32 F)** | 43.05 V | 13 panels | 559.6 V | 23 panels |
| **25 C (77 F STC)** | 40.1 V | 14 panels | 561.4 V | 24 panels |

## Which Cross-Brand Solar Modules Compare Closest to GCL System Integration Technology Co Ltd GCL-M6/60315?

Alternative CEC solar modules from competing brands near GCL System Integration Technology Co Ltd GCL-M6/60315 (315.0 W), including AXITEC AC-315MH/120S.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**AXITEC AC-315MH/120S**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-315mh-120s/) AXITEC | 315.0 W | Tie (0 W) | 39.74 V | 18.96% | 93.0% |
| [**AXITEC AC-315MH/120V**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-315mh-120v/) AXITEC | 315.0 W | Tie (0 W) | 39.74 V | 18.96% | 93.0% |
| [**CertainTeed CT315HC11-04**](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-ct315hc11-04/) CertainTeed | 315.0 W | Tie (0 W) | 39.74 V | 19.58% | 92.2% |
| [**Boviet Solar Technology Co Ltd BVM6610M-310**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6610m-310/) Boviet Solar Technology Co Ltd | 310.0 W | -5.0 W | 40.1 V | 19.05% | 92.2% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for GCL System Integration Technology Co Ltd GCL-M6/60315?

Evaluate GCL System Integration Technology Co Ltd GCL-M6/60315 (315.0 W STC, 40.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), GCL System Integration Technology Co Ltd GCL-M6/60315 reaches 45.41 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 26 panels for an 8 kW build require 456 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (456 sq ft).
- 2026 tax credit baseline: cash residential installs of GCL System Integration Technology Co Ltd GCL-M6/60315 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### GCL System Integration Technology Co Ltd GCL-M6/60315 8 kW Residential Fit

Needs 26 modules (456 sq ft) with a 20 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare AXITEC AC-315MH/120S.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 287.6 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for GCL System Integration Technology Co Ltd GCL-M6/60315 by GCL System Integration Technology Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for GCL System Integration Technology Co Ltd GCL-M6/60315?

Multiplying GCL System Integration Technology Co Ltd GCL-M6/60315's 10.04 A short-circuit current by 1.56 equals 15.66 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

### Can GCL System Integration Technology Co Ltd GCL-M6/60315 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 44.23 V cold Voc at 14 F and handles 10.04 A Isc; string inverters cap GCL System Integration Technology Co Ltd GCL-M6/60315 at 13 panels on 600 V.

### Is GCL System Integration Technology Co Ltd GCL-M6/60315 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of GCL System Integration Technology Co Ltd GCL-M6/60315 rely on utility bill offset (~$2,050/yr at 8 kW) rather than 25D.

## Related Pages

Compare GCL System Integration Technology Co Ltd equipment, AXITEC AC-315MH/120S specs, utility payback rates, and NEC string calculators alongside GCL System Integration Technology Co Ltd GCL-M6/60315.

[All GCL System Integration Technology Co Ltd Certified Solar Models](https://epri-peac.com/solar-equipment/brands/gcl-system-integration-technology-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From GCL System Integration Technology Co Ltd

- [All GCL System Integration Technology Co Ltd Specs](https://epri-peac.com/solar-equipment/brands/gcl-system-integration-technology-co-ltd/)
- [GCL System Integration Technology Co Ltd GCL-M10/72GDF555](https://epri-peac.com/solar-equipment/modules/gcl-system-integration-technology-co-ltd/gcl-system-integration-technology-co-ltd-gcl-m10-72gdf555/)
- [GCL System Integration Technology Co Ltd GCL-M10/72GDF540](https://epri-peac.com/solar-equipment/modules/gcl-system-integration-technology-co-ltd/gcl-system-integration-technology-co-ltd-gcl-m10-72gdf540/)
- [GCL System Integration Technology Co Ltd GCL-M3/72DH385](https://epri-peac.com/solar-equipment/modules/gcl-system-integration-technology-co-ltd/gcl-system-integration-technology-co-ltd-gcl-m3-72dh385/)
- [GCL System Integration Technology Co Ltd GCL-M3/72GDF385](https://epri-peac.com/solar-equipment/modules/gcl-system-integration-technology-co-ltd/gcl-system-integration-technology-co-ltd-gcl-m3-72gdf385/)
- [GCL System Integration Technology Co Ltd GCL-M3/72H385](https://epri-peac.com/solar-equipment/modules/gcl-system-integration-technology-co-ltd/gcl-system-integration-technology-co-ltd-gcl-m3-72h385/)