title: "Gautam Solar Pvt Ltd G2X1710N-UHAD Specs (570.0W, 50.74V Voc)"
url: https://epri-peac.com/solar-equipment/modules/gautam-solar-pvt-ltd/gautam-solar-pvt-ltd-g2x1710n-uhad/
description: "CEC datasheet for Gautam Solar Pvt Ltd G2X1710N-UHAD: 570.0W STC, 50.74V Voc, 15-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# Gautam Solar Pvt Ltd G2X1710N-UHAD — CEC Solar Module Specifications

Manufacturer: [**Gautam Solar Pvt Ltd**](https://epri-peac.com/solar-equipment/brands/gautam-solar-pvt-ltd/) Registry: **CEC Verified Engineering Specification**

Gautam Solar Pvt Ltd G2X1710N-UHAD is a 570.0 W STC (540.7 W PTC) Mono-c-Si solar module ranking #2,154 of 21,677 CEC listings (top 10.5%; higher than 89.5% of peers). It delivers 22.18% efficiency, 50.74 V Voc at 25 C, and 54.93 V cold Voc at -10 C (10 panels max per 600 V string).

- **STC Wattage** : 570.0 W

- **PTC Wattage** : 540.7 W

- **Voc @ 25C** : 50.74 V

- **Efficiency** : 22.18%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Gautam Solar Pvt Ltd G2X1710N-UHAD Compare Against Peer CEC Listings?

How Gautam Solar Pvt Ltd Gautam Solar Pvt Ltd G2X1710N-UHAD handles rooftop heat (540.7 W PTC), 8 kW sizing, and cold winter string voltage.

Gautam Solar Pvt Ltd builds the Gautam Solar Pvt Ltd G2X1710N-UHAD (Mono-c-Si) as a large-format commercial and ground-mount module delivering 221.8 W/m2 (2.27 percentage points above 19.91% CEC median). Compared against CSI Solar Co Ltd CS6W-570TB-AG (570.0 W), this model holds strong 94.9% PTC-to-STC heat retention (#1,466 of 21,677). Higher 50.74 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C), while NEC 690.8 sets a 22.32 A overcurrent floor served by a 25 A breaker.

## Where Does Gautam Solar Pvt Ltd G2X1710N-UHAD Fall Across Listed CEC Models?

Where Gautam Solar Pvt Ltd G2X1710N-UHAD (570.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Gautam Solar Pvt Ltd G2X1710N-UHAD?

Percentile placement of Gautam Solar Pvt Ltd G2X1710N-UHAD across power density (221.8 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for Gautam Solar Pvt Ltd G2X1710N-UHAD?

Four critical engineering numbers homeowners and solar installers check first when reviewing Gautam Solar Pvt Ltd G2X1710N-UHAD specifications.

Rank #2,154 / 21,677

### Top 10.5% STC Output

570.0 W STC (+185.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #2,702

### 22.18% Aperture Efficiency

Power density 221.8 W/m2 (2.27 percentage points above 19.91% CEC median). PTC/STC ratio: 94.9% (rank #1,466).

NEC 690.7 Limit

### 10 Panels Max @ -10 C (600 V)

Cold Voc reaches 54.93 V at -10 C (549.3 V string) and 56.13 V at -20 C (10 max).

 8 kW Reference Array

### 15 Panels = 8,550 W STC

Occupies 38.5 m2 (415 sq ft) producing 8,110 W PTC; NEC 690.8 OCPD floor is 22.32 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 50.74 * (1 + (-0.236/100) * (-10 - 25)) = 54.93 V | OCPD = 1.56 * 14.31 = 22.32 A

Inputs from CEC Modules.csv for Gautam Solar Pvt Ltd G2X1710N-UHAD: Voc=50.74 V, beta_Voc=-0.236%/C, Isc=14.31 A, STC=570.0 W, Area=2.57 m2.

**Result:** 10 panels max on 600 V (549.3 V); 15 panels for 8 kW (415 sq ft).

## What Are the Published CEC Specifications for Gautam Solar Pvt Ltd G2X1710N-UHAD?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Gautam Solar Pvt Ltd G2X1710N-UHAD.

Official California Energy Commission (NREL SAM) test parameters for Gautam Solar Pvt Ltd G2X1710N-UHAD.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 570.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 540.7 W (94.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 50.74 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 14.31 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 42.07 V / 13.56 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.236 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 22.18% (2.57 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Bifacial glass-glass |

## How Many Gautam Solar Pvt Ltd G2X1710N-UHAD Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Gautam Solar Pvt Ltd G2X1710N-UHAD (570.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 11 | 6.27 kW | 304 sq ft | $1,569 | $2,654 |
| **8 kW Class** | 15 | 8.55 kW | 415 sq ft | $2,140 | $3,619 |
| **10 kW Class** | 18 | 10.26 kW | 498 sq ft | $2,568 | $4,342 |

## How Many Gautam Solar Pvt Ltd G2X1710N-UHAD Modules Fit in a Cold-Weather String?

Maximum series module counts for Gautam Solar Pvt Ltd G2X1710N-UHAD from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=50.74V and beta_Voc=-0.236%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 56.13 V | 10 panels | 561.3 V | 17 panels |
| **-10 C (14 F)** | 54.93 V | 10 panels | 549.3 V | 18 panels |
| **0 C (32 F)** | 53.73 V | 11 panels | 591.0 V | 18 panels |
| **25 C (77 F STC)** | 50.74 V | 11 panels | 558.1 V | 19 panels |

## Which Cross-Brand Solar Modules Compare Closest to Gautam Solar Pvt Ltd G2X1710N-UHAD?

Alternative CEC solar modules from competing brands near Gautam Solar Pvt Ltd G2X1710N-UHAD (570.0 W), including CSI Solar Co Ltd CS6W-570TB-AG.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**CSI Solar Co Ltd CS6W-570TB-AG**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6w-570tb-ag/) CSI Solar Co Ltd | 570.0 W | Tie (0 W) | 51.8 V | 22.71% | 94.9% |
| [**CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI FE72-18X(ND)-565**](https://epri-peac.com/solar-equipment/modules/chen-gunes-enerjisi-sanayi-ve-ticaret-limited-sirketi/chen-gunes-enerjisi-sanayi-ve-ticaret-limited-sirketi-fe72-18x-nd-565/) CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI | 565.0 W | -5.0 W | 50.7 V | 22.07% | 94.1% |
| [**GOLDI SUN PRIVATE LIMITED GS10-T144-GF-565**](https://epri-peac.com/solar-equipment/modules/goldi-sun-private-limited/goldi-sun-private-limited-gs10-t144-gf-565/) GOLDI SUN PRIVATE LIMITED | 565.0 W | -5.0 W | 50.88 V | 21.9% | 94.5% |
| [**EMMVEE Photovoltaic Power Private Limited E575HCBG144-T**](https://epri-peac.com/solar-equipment/modules/emmvee-photovoltaic-power-private-limited/emmvee-photovoltaic-power-private-limited-e575hcbg144-t/) EMMVEE Photovoltaic Power Private Limited | 575.0 W | +5.0 W | 51.27 V | 22.46% | 93.4% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Gautam Solar Pvt Ltd G2X1710N-UHAD?

Evaluate Gautam Solar Pvt Ltd G2X1710N-UHAD (570.0 W STC, 50.74 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Gautam Solar Pvt Ltd G2X1710N-UHAD reaches 56.13 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 15 panels for an 8 kW build require 415 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Gautam Solar Pvt Ltd G2X1710N-UHAD carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Gautam Solar Pvt Ltd G2X1710N-UHAD 8 kW Residential Fit

Needs 15 modules (415 sq ft) with a 25 A string OCPD, offsetting ~$2,140/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare CSI Solar Co Ltd CS6W-570TB-AG.

### Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 540.7 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Gautam Solar Pvt Ltd G2X1710N-UHAD by Gautam Solar Pvt Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Gautam Solar Pvt Ltd G2X1710N-UHAD?

Multiplying Gautam Solar Pvt Ltd G2X1710N-UHAD's 14.31 A short-circuit current by 1.56 equals 22.32 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

### Can Gautam Solar Pvt Ltd G2X1710N-UHAD pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 54.93 V cold Voc at 14 F and handles 14.31 A Isc; string inverters cap Gautam Solar Pvt Ltd G2X1710N-UHAD at 10 panels on 600 V.

### Is Gautam Solar Pvt Ltd G2X1710N-UHAD eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Gautam Solar Pvt Ltd G2X1710N-UHAD rely on utility bill offset (~$2,140/yr at 8 kW) rather than 25D.

## Related Pages

Compare Gautam Solar Pvt Ltd equipment, CSI Solar Co Ltd CS6W-570TB-AG specs, utility payback rates, and NEC string calculators alongside Gautam Solar Pvt Ltd G2X1710N-UHAD.

[All Gautam Solar Pvt Ltd Certified Solar Models](https://epri-peac.com/solar-equipment/brands/gautam-solar-pvt-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Gautam Solar Pvt Ltd

- [All Gautam Solar Pvt Ltd Specs](https://epri-peac.com/solar-equipment/brands/gautam-solar-pvt-ltd/)
- [Gautam Solar Pvt Ltd G2G1800-HAD](https://epri-peac.com/solar-equipment/modules/gautam-solar-pvt-ltd/gautam-solar-pvt-ltd-g2g1800-had/)
- [Gautam Solar Pvt Ltd G2X1800N-UHAD](https://epri-peac.com/solar-equipment/modules/gautam-solar-pvt-ltd/gautam-solar-pvt-ltd-g2x1800n-uhad/)
- [Gautam Solar Pvt Ltd G2G1785-HAD](https://epri-peac.com/solar-equipment/modules/gautam-solar-pvt-ltd/gautam-solar-pvt-ltd-g2g1785-had/)
- [Gautam Solar Pvt Ltd G2X1785N-UHAD](https://epri-peac.com/solar-equipment/modules/gautam-solar-pvt-ltd/gautam-solar-pvt-ltd-g2x1785n-uhad/)
- [Gautam Solar Pvt Ltd G2G1770-HAD](https://epri-peac.com/solar-equipment/modules/gautam-solar-pvt-ltd/gautam-solar-pvt-ltd-g2g1770-had/)