---
title: "GAF Energy LLC TLS-2-56 Specs (56.0W, 10.66V Voc)"
url: https://epri-peac.com/solar-equipment/modules/gaf-energy-llc/gaf-energy-llc-tls-2-56/
description: "CEC datasheet for GAF Energy LLC TLS-2-56: 56.0W STC, 10.66V Voc, 143-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# GAF Energy LLC TLS-2-56 — CEC Solar Module Specifications

Manufacturer: [**GAF Energy LLC**](https://epri-peac.com/solar-equipment/brands/gaf-energy-llc/) Registry: **CEC Verified Engineering Specification**

GAF Energy LLC TLS-2-56 is a 56.0 W STC (48.1 W PTC) Mono-c-Si solar module ranking #21,658 of 21,677 CEC listings (below all-CEC median; higher than 0.1% of peers). It delivers 8.0% efficiency, 10.66 V Voc at 25 C, and 11.72 V cold Voc at -10 C (51 panels max per 600 V string).

- **STC Wattage** : 56.0 W

- **PTC Wattage** : 48.1 W

- **Voc @ 25C** : 10.66 V

- **Efficiency** : 8.0%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does GAF Energy LLC TLS-2-56 Compare Against Peer CEC Listings?

Engineering position of GAF Energy LLC TLS-2-56 (56.0 W STC) vs. Sunflare Co FLEX20-55W across 5,889 CEC Mono-c-Si solar modules.

Built with 8 Mono-c-Si cells, GAF Energy LLC TLS-2-56 pairs typical 85.9% PTC-to-STC thermal output (48.1 W real-world rating) with 10.66 V nominal Voc. An 8 kW residential build (8,008 W DC, 6,878 W PTC) saves ~$2,005/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Sunflare Co FLEX20-55W offers a 55.0 W alternative.

## Where Does GAF Energy LLC TLS-2-56 Fall Across Listed CEC Models?

Plots GAF Energy LLC TLS-2-56 at 56.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

## What Dataset Percentiles Define GAF Energy LLC TLS-2-56?

Benchmarks GAF Energy LLC TLS-2-56 on STC wattage, thermal PTC/STC retention, and 8.0 aperture conversion efficiency against CEC peers.

## What Do the Dataset Ranks Show for GAF Energy LLC TLS-2-56?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for GAF Energy LLC TLS-2-56 by GAF Energy LLC.

Rank #21,658 / 21,677

### 56.0 W STC · Higher Than 0.1%

56.0 W STC (-329.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #21,655

### 8.0% Aperture Efficiency

Power density 80.0 W/m2 (11.91 percentage points below 19.91% CEC median). PTC/STC ratio: 85.9% (rank #21,652).

NEC 690.7 Limit

### 51 Panels Max @ -10 C (600 V)

Cold Voc reaches 11.72 V at -10 C (597.7 V string) and 12.02 V at -20 C (49 max).

 8 kW Reference Array

### 143 Panels = 8,008 W STC

Occupies 100.1 m2 (1,077 sq ft) producing 6,878 W PTC; NEC 690.8 OCPD floor is 10.34 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 10.66 * (1 + (-0.284/100) * (-10 - 25)) = 11.72 V | OCPD = 1.56 * 6.63 = 10.34 A

Inputs from CEC Modules.csv for GAF Energy LLC TLS-2-56: Voc=10.66 V, beta_Voc=-0.284%/C, Isc=6.63 A, STC=56.0 W, Area=0.7 m2.

**Result:** 51 panels max on 600 V (597.7 V); 143 panels for 8 kW (1,077 sq ft).

## What Are the Published CEC Specifications for GAF Energy LLC TLS-2-56?

Laboratory test ratings recorded for GAF Energy LLC TLS-2-56 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for GAF Energy LLC TLS-2-56.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 56.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 48.1 W (85.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 10.66 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 6.63 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 8.9 V / 6.29 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.284 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 8.0% (0.7 m2) | Array roof footprint density |
| **Cell Count & Technology** | 8 cells (Mono-c-Si) | Monofacial backsheet |

## How Many GAF Energy LLC TLS-2-56 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (1,077 sq ft at 8 kW), and estimated Year-1 electric bill offset for GAF Energy LLC TLS-2-56.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 108 | 6.05 kW | 814 sq ft | $1,514 | $2,561 |
| **8 kW Class** | 143 | 8.01 kW | 1,077 sq ft | $2,005 | $3,390 |
| **10 kW Class** | 179 | 10.02 kW | 1,349 sq ft | $2,508 | $4,241 |

## How Many GAF Energy LLC TLS-2-56 Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for GAF Energy LLC TLS-2-56 (beta_Voc -0.284%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=10.66V and beta_Voc=-0.284%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 12.02 V | 49 panels | 589.0 V | 83 panels |
| **-10 C (14 F)** | 11.72 V | 51 panels | 597.7 V | 85 panels |
| **0 C (32 F)** | 11.42 V | 52 panels | 593.8 V | 87 panels |
| **25 C (77 F STC)** | 10.66 V | 56 panels | 597.0 V | 93 panels |

## Which Cross-Brand Solar Modules Compare Closest to GAF Energy LLC TLS-2-56?

Closest cross-brand CEC competitors to GAF Energy LLC TLS-2-56 matched near 56.0 W STC and 10.66 V Voc, led by Sunflare Co FLEX20-55W.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Sunflare Co FLEX20-55W**](https://epri-peac.com/solar-equipment/modules/sunflare-co/sunflare-co-flex20-55w/) Sunflare Co | 55.0 W | -1.0 W | 12.0 V | 9.32% | 90.0% |
| [**HALEE Inc HST-61-E-FP**](https://epri-peac.com/solar-equipment/modules/halee-inc/halee-inc-hst-61-e-fp/) HALEE Inc | 61.0 W | +5.0 W | 9.5 V | 14.88% | 85.6% |
| [**Sunflare Co FLEX20-60W**](https://epri-peac.com/solar-equipment/modules/sunflare-co/sunflare-co-flex20-60w/) Sunflare Co | 60.0 W | +4.0 W | 12.5 V | 10.17% | 90.2% |
| [**Tesla Inc SR60T1**](https://epri-peac.com/solar-equipment/modules/tesla-inc/tesla-inc-sr60t1/) Tesla Inc | 58.5 W | +2.5 W | 13.34 V | 11.93% | 89.1% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for GAF Energy LLC TLS-2-56?

Evaluate GAF Energy LLC TLS-2-56 (56.0 W STC, 10.66 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), GAF Energy LLC TLS-2-56 reaches 12.02 V per panel—exceeding 49 panels in series voids 600 V inverter warranties.
- Footprint constraint: 143 panels for an 8 kW build require 1,077 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 143 panels (1,077 sq ft).
- 2026 tax credit baseline: cash residential installs of GAF Energy LLC TLS-2-56 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### GAF Energy LLC TLS-2-56 8 kW Residential Fit

Needs 143 modules (1,077 sq ft) with a 15 A string OCPD, offsetting ~$2,005/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 51 panels (-10 C) or 49 panels (-20 C), or compare Sunflare Co FLEX20-55W.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 48.1 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for GAF Energy LLC TLS-2-56 by GAF Energy LLC grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for GAF Energy LLC TLS-2-56?

Multiplying GAF Energy LLC TLS-2-56's 6.63 A short-circuit current by 1.56 equals 10.34 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

### Can GAF Energy LLC TLS-2-56 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 11.72 V cold Voc at 14 F and handles 6.63 A Isc; string inverters cap GAF Energy LLC TLS-2-56 at 51 panels on 600 V.

### Is GAF Energy LLC TLS-2-56 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of GAF Energy LLC TLS-2-56 rely on utility bill offset (~$2,005/yr at 8 kW) rather than 25D.

## Related Pages

Compare GAF Energy LLC equipment, Sunflare Co FLEX20-55W specs, utility payback rates, and NEC string calculators alongside GAF Energy LLC TLS-2-56.

[All GAF Energy LLC Certified Solar Models](https://epri-peac.com/solar-equipment/brands/gaf-energy-llc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From GAF Energy LLC

- [All GAF Energy LLC Specs](https://epri-peac.com/solar-equipment/brands/gaf-energy-llc/)
- [GAF Energy LLC TLS-2-58](https://epri-peac.com/solar-equipment/modules/gaf-energy-llc/gaf-energy-llc-tls-2-58/)
- [GAF Energy LLC TLS-2J-58](https://epri-peac.com/solar-equipment/modules/gaf-energy-llc/gaf-energy-llc-tls-2j-58/)
- [GAF Energy LLC TLS-2](https://epri-peac.com/solar-equipment/modules/gaf-energy-llc/gaf-energy-llc-tls-2/)
- [GAF Energy LLC TLS-2J](https://epri-peac.com/solar-equipment/modules/gaf-energy-llc/gaf-energy-llc-tls-2j/)
- [GAF Energy LLC TLS-2J-56](https://epri-peac.com/solar-equipment/modules/gaf-energy-llc/gaf-energy-llc-tls-2j-56/)
