title: "FreeVolt ECP-PVGRAF-120HC-375W Specs (freevolt-ecp-p)"
url: https://epri-peac.com/solar-equipment/modules/freevolt/freevolt-ecp-pvgraf-120hc-375w-black/
description: "CEC datasheet for FreeVolt ECP-PVGRAF-120HC-375W Black: 375.0W STC, 41.1V Voc, 22-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# FreeVolt ECP-PVGRAF-120HC-375W Black — CEC Solar Module Specifications

Manufacturer: [**FreeVolt**](https://epri-peac.com/solar-equipment/brands/freevolt/) Registry: **CEC Verified Engineering Specification**

FreeVolt ECP-PVGRAF-120HC-375W Black is a 375.0 W STC (350.3 W PTC) Mono-c-Si solar module ranking #11,367 of 21,677 CEC listings (below all-CEC median; higher than 46.0% of peers). It delivers 20.49% efficiency, 41.1 V Voc at 25 C, and 45.14 V cold Voc at -10 C (13 panels max per 600 V string).

- **STC Wattage** : 375.0 W

- **PTC Wattage** : 350.3 W

- **Voc @ 25C** : 41.1 V

- **Efficiency** : 20.49%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does FreeVolt ECP-PVGRAF-120HC-375W Black Compare Against Peer CEC Listings?

Solar engineering breakdown for FreeVolt ECP-PVGRAF-120HC-375W Black: PTC thermal retention, roof footprint, and cold Voc string bounds. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Across 5,889 Mono-c-Si listings from FreeVolt and peers, FreeVolt ECP-PVGRAF-120HC-375W Black stands 35.0 W below the 410.0 W Mono-c-Si median and strong 93.4% PTC-to-STC heat retention (#7,716 of 21,677). Sizing 6 kW (16 panels) to 10 kW (27 panels) yields $1,502-$2,533/yr in baseline US bill offset. Mid-range 41.1 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F.

## Where Does FreeVolt ECP-PVGRAF-120HC-375W Black Fall Across Listed CEC Models?

Distribution marker showing FreeVolt ECP-PVGRAF-120HC-375W Black (375.0 W) relative to the 385.0 W all-CEC solar panel median. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

## What Dataset Percentiles Define FreeVolt ECP-PVGRAF-120HC-375W Black?

Dataset percentiles tracking FreeVolt ECP-PVGRAF-120HC-375W Black power output, thermal retention ratio, and aperture efficiency against 21,677 models. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

## What Do the Dataset Ranks Show for FreeVolt ECP-PVGRAF-120HC-375W Black?

Benchmark highlights for FreeVolt ECP-PVGRAF-120HC-375W Black covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Rank #11,367 / 21,677

### 375.0 W STC · Higher Than 46.0%

375.0 W STC (-10.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #8,658

### 20.49% Aperture Efficiency

Power density 204.9 W/m2 (0.58 percentage points above 19.91% CEC median). PTC/STC ratio: 93.4% (rank #7,716).

NEC 690.7 Limit

### 13 Panels Max @ -10 C (600 V)

Cold Voc reaches 45.14 V at -10 C (586.8 V string) and 46.3 V at -20 C (12 max).

 8 kW Reference Array

### 22 Panels = 8,250 W STC

Occupies 40.3 m2 (433 sq ft) producing 7,707 W PTC; NEC 690.8 OCPD floor is 18.1 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 41.1 * (1 + (-0.281/100) * (-10 - 25)) = 45.14 V | OCPD = 1.56 * 11.6 = 18.1 A

Inputs from CEC Modules.csv for FreeVolt ECP-PVGRAF-120HC-375W Black: Voc=41.1 V, beta_Voc=-0.281%/C, Isc=11.6 A, STC=375.0 W, Area=1.83 m2.

**Result:** 13 panels max on 600 V (586.8 V); 22 panels for 8 kW (433 sq ft).

## What Are the Published CEC Specifications for FreeVolt ECP-PVGRAF-120HC-375W Black?

Official CEC datasheet figures for FreeVolt ECP-PVGRAF-120HC-375W Black (Mono-c-Si) used in utility interconnection and permit reviews. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Official California Energy Commission (NREL SAM) test parameters for FreeVolt ECP-PVGRAF-120HC-375W Black.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 375.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 350.3 W (93.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 41.1 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 11.6 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 34.6 V / 10.84 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.281 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 20.49% (1.83 m2) | Array roof footprint density |
| **Cell Count & Technology** | 40 cells (Mono-c-Si) | Monofacial backsheet |

## How Many FreeVolt ECP-PVGRAF-120HC-375W Black Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many FreeVolt ECP-PVGRAF-120HC-375W Black modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 16 | 6.0 kW | 315 sq ft | $1,502 | $2,539 |
| **8 kW Class** | 22 | 8.25 kW | 433 sq ft | $2,065 | $3,492 |
| **10 kW Class** | 27 | 10.12 kW | 532 sq ft | $2,533 | $4,283 |

## How Many FreeVolt ECP-PVGRAF-120HC-375W Black Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on FreeVolt ECP-PVGRAF-120HC-375W Black (45.14 V at 14 F).

Computed from Voc=41.1V and beta_Voc=-0.281%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 46.3 V | 12 panels | 555.6 V | 21 panels |
| **-10 C (14 F)** | 45.14 V | 13 panels | 586.8 V | 22 panels |
| **0 C (32 F)** | 43.99 V | 13 panels | 571.9 V | 22 panels |
| **25 C (77 F STC)** | 41.1 V | 14 panels | 575.4 V | 24 panels |

## Which Cross-Brand Solar Modules Compare Closest to FreeVolt ECP-PVGRAF-120HC-375W Black?

Competing CEC solar panels closest to FreeVolt ECP-PVGRAF-120HC-375W Black in nameplate wattage and Voc, starting with Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-375W.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-375W**](https://epri-peac.com/solar-equipment/modules/amerisolar-worldwide-energy-and-manufacturing-usa-co-ltd/amerisolar-worldwide-energy-and-manufacturing-usa-co-ltd-as-6m120-bhc-375w/) Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd | 375.0 W | Tie (0 W) | 41.1 V | 21.07% | 92.6% |
| [**Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-375W**](https://epri-peac.com/solar-equipment/modules/amerisolar-worldwide-energy-and-manufacturing-usa-co-ltd/amerisolar-worldwide-energy-and-manufacturing-usa-co-ltd-as-6m120-hc-375w/) Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd | 375.0 W | Tie (0 W) | 41.1 V | 20.72% | 92.4% |
| [**Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-375W Black**](https://epri-peac.com/solar-equipment/modules/amerisolar-worldwide-energy-and-manufacturing-usa-co-ltd/amerisolar-worldwide-energy-and-manufacturing-usa-co-ltd-as-6m120-hc-375w-black/) Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd | 375.0 W | Tie (0 W) | 41.1 V | 20.49% | 93.4% |
| [**AXITEC AC-375MH/120V**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-375mh-120v/) AXITEC | 375.0 W | Tie (0 W) | 41.1 V | 20.72% | 92.4% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for FreeVolt ECP-PVGRAF-120HC-375W Black?

Evaluate FreeVolt ECP-PVGRAF-120HC-375W Black (375.0 W STC, 41.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), FreeVolt ECP-PVGRAF-120HC-375W Black reaches 46.3 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 22 panels for an 8 kW build require 433 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (433 sq ft).
- 2026 tax credit baseline: cash residential installs of FreeVolt ECP-PVGRAF-120HC-375W Black carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### FreeVolt ECP-PVGRAF-120HC-375W Black 8 kW Residential Fit

Needs 22 modules (433 sq ft) with a 20 A string OCPD, offsetting ~$2,065/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-375W.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 350.3 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for FreeVolt ECP-PVGRAF-120HC-375W Black by FreeVolt grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for FreeVolt ECP-PVGRAF-120HC-375W Black?

Multiplying FreeVolt ECP-PVGRAF-120HC-375W Black's 11.6 A short-circuit current by 1.56 equals 18.1 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

### Can FreeVolt ECP-PVGRAF-120HC-375W Black pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 45.14 V cold Voc at 14 F and handles 11.6 A Isc; string inverters cap FreeVolt ECP-PVGRAF-120HC-375W Black at 13 panels on 600 V.

### Is FreeVolt ECP-PVGRAF-120HC-375W Black eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of FreeVolt ECP-PVGRAF-120HC-375W Black rely on utility bill offset (~$2,065/yr at 8 kW) rather than 25D.

## Related Pages

Compare FreeVolt equipment, Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-375W specs, utility payback rates, and NEC string calculators alongside FreeVolt ECP-PVGRAF-120HC-375W Black.

[All FreeVolt Certified Solar Models](https://epri-peac.com/solar-equipment/brands/freevolt/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From FreeVolt

- [All FreeVolt Specs](https://epri-peac.com/solar-equipment/brands/freevolt/)
- [FreeVolt ECP-PVGRAF-HC-BF585-144MT-B](https://epri-peac.com/solar-equipment/modules/freevolt/freevolt-ecp-pvgraf-hc-bf585-144mt-b/)
- [FreeVolt ECP-PVGRAF-HC-BF585-144MT-W](https://epri-peac.com/solar-equipment/modules/freevolt/freevolt-ecp-pvgraf-hc-bf585-144mt-w/)
- [FreeVolt ECP-PVGRAF-HC-BF560-144MT-B](https://epri-peac.com/solar-equipment/modules/freevolt/freevolt-ecp-pvgraf-hc-bf560-144mt-b/)
- [FreeVolt ECP-PVGRAF-HC-BF560-144MT-W](https://epri-peac.com/solar-equipment/modules/freevolt/freevolt-ecp-pvgraf-hc-bf560-144mt-w/)
- [FreeVolt ECP-PVGRAF-144BHC-450W](https://epri-peac.com/solar-equipment/modules/freevolt/freevolt-ecp-pvgraf-144bhc-450w/)