title: "FreeVolt ECP-PVGRAF-120HC-360W Specs (freevolt-ecp-p)"
url: https://epri-peac.com/solar-equipment/modules/freevolt/freevolt-ecp-pvgraf-120hc-360w-black/
description: "CEC datasheet for FreeVolt ECP-PVGRAF-120HC-360W Black: 360.0W STC, 40.5V Voc, 23-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# FreeVolt ECP-PVGRAF-120HC-360W Black — CEC Solar Module Specifications

Manufacturer: [**FreeVolt**](https://epri-peac.com/solar-equipment/brands/freevolt/) Registry: **CEC Verified Engineering Specification**

FreeVolt ECP-PVGRAF-120HC-360W Black is a 360.0 W STC (335.9 W PTC) Mono-c-Si solar module ranking #12,385 of 21,677 CEC listings (below all-CEC median; higher than 41.3% of peers). It delivers 19.67% efficiency, 40.5 V Voc at 25 C, and 44.48 V cold Voc at -10 C (13 panels max per 600 V string).

- **STC Wattage** : 360.0 W

- **PTC Wattage** : 335.9 W

- **Voc @ 25C** : 40.5 V

- **Efficiency** : 19.67%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does FreeVolt ECP-PVGRAF-120HC-360W Black Compare Against Peer CEC Listings?

How FreeVolt FreeVolt ECP-PVGRAF-120HC-360W Black handles rooftop heat (335.9 W PTC), 8 kW sizing, and cold winter string voltage.

FreeVolt builds the FreeVolt ECP-PVGRAF-120HC-360W Black (Mono-c-Si) as a compact residential or specialty off-grid module delivering 196.7 W/m2 (0.24 percentage points below 19.91% CEC median). Compared against Apollo Renewables Inc Apollo-M660BH-360BB (360.0 W), this model holds strong 93.3% PTC-to-STC heat retention (#8,323 of 21,677). Mid-range 40.5 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F, while NEC 690.8 sets a 17.71 A overcurrent floor served by a 20 A breaker.

## Where Does FreeVolt ECP-PVGRAF-120HC-360W Black Fall Across Listed CEC Models?

Where FreeVolt ECP-PVGRAF-120HC-360W Black (360.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define FreeVolt ECP-PVGRAF-120HC-360W Black?

Percentile placement of FreeVolt ECP-PVGRAF-120HC-360W Black across power density (196.7 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for FreeVolt ECP-PVGRAF-120HC-360W Black?

Four critical engineering numbers homeowners and solar installers check first when reviewing FreeVolt ECP-PVGRAF-120HC-360W Black specifications. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Rank #12,385 / 21,677

### 360.0 W STC · Higher Than 41.3%

360.0 W STC (-25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #11,599

### 19.67% Aperture Efficiency

Power density 196.7 W/m2 (0.24 percentage points below 19.91% CEC median). PTC/STC ratio: 93.3% (rank #8,323).

NEC 690.7 Limit

### 13 Panels Max @ -10 C (600 V)

Cold Voc reaches 44.48 V at -10 C (578.2 V string) and 45.62 V at -20 C (13 max).

 8 kW Reference Array

### 23 Panels = 8,280 W STC

Occupies 42.1 m2 (453 sq ft) producing 7,726 W PTC; NEC 690.8 OCPD floor is 17.71 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 40.5 * (1 + (-0.281/100) * (-10 - 25)) = 44.48 V | OCPD = 1.56 * 11.35 = 17.71 A

Inputs from CEC Modules.csv for FreeVolt ECP-PVGRAF-120HC-360W Black: Voc=40.5 V, beta_Voc=-0.281%/C, Isc=11.35 A, STC=360.0 W, Area=1.83 m2.

**Result:** 13 panels max on 600 V (578.2 V); 23 panels for 8 kW (453 sq ft).

## What Are the Published CEC Specifications for FreeVolt ECP-PVGRAF-120HC-360W Black?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for FreeVolt ECP-PVGRAF-120HC-360W Black.

Official California Energy Commission (NREL SAM) test parameters for FreeVolt ECP-PVGRAF-120HC-360W Black.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 360.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 335.9 W (93.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 40.5 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 11.35 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 34.0 V / 10.59 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.281 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 19.67% (1.83 m2) | Array roof footprint density |
| **Cell Count & Technology** | 40 cells (Mono-c-Si) | Monofacial backsheet |

## How Many FreeVolt ECP-PVGRAF-120HC-360W Black Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using FreeVolt ECP-PVGRAF-120HC-360W Black (360.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 17 | 6.12 kW | 335 sq ft | $1,532 | $2,590 |
| **8 kW Class** | 23 | 8.28 kW | 453 sq ft | $2,072 | $3,504 |
| **10 kW Class** | 28 | 10.08 kW | 552 sq ft | $2,523 | $4,266 |

## Which Sibling Wattage & Trim Variants Belong to This FreeVolt Series?

All closely matched FreeVolt wattages and cosmetic trims sharing the FreeVolt ECP-PVGRAF-120HC-360W Black architecture. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Sibling CEC listings grouped into the FreeVolt ECP-PVGRAF-120HC-360W Black wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **FreeVolt ECP-PVGRAF-120HC-350W Black** | 350.0 W | 326.3 W | 40.1 V | 33.6 V | 19.13% |
| **FreeVolt ECP-PVGRAF-120HC-355W Black** | 355.0 W | 331.1 W | 40.3 V | 33.8 V | 19.4% |
| **FreeVolt ECP-PVGRAF-120HC-360W Black** | 360.0 W | 335.9 W | 40.5 V | 34.0 V | 19.67% |
| **FreeVolt ECP-PVGRAF-120HC-365W Black** | 365.0 W | 340.7 W | 40.7 V | 34.2 V | 19.95% |
| **FreeVolt ECP-PVGRAF-120HC-370W Black** | 370.0 W | 345.5 W | 40.9 V | 34.4 V | 20.22% |

## How Many FreeVolt ECP-PVGRAF-120HC-360W Black Modules Fit in a Cold-Weather String?

Maximum series module counts for FreeVolt ECP-PVGRAF-120HC-360W Black from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=40.5V and beta_Voc=-0.281%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 45.62 V | 13 panels | 593.1 V | 21 panels |
| **-10 C (14 F)** | 44.48 V | 13 panels | 578.2 V | 22 panels |
| **0 C (32 F)** | 43.35 V | 13 panels | 563.6 V | 23 panels |
| **25 C (77 F STC)** | 40.5 V | 14 panels | 567.0 V | 24 panels |

## Which Cross-Brand Solar Modules Compare Closest to FreeVolt ECP-PVGRAF-120HC-360W Black?

Alternative CEC solar modules from competing brands near FreeVolt ECP-PVGRAF-120HC-360W Black (360.0 W), including Apollo Renewables Inc Apollo-M660BH-360BB.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Apollo Renewables Inc Apollo-M660BH-360BB**](https://epri-peac.com/solar-equipment/modules/apollo-renewables-inc/apollo-renewables-inc-apollo-m660bh-360bb/) Apollo Renewables Inc | 360.0 W | Tie (0 W) | 40.5 V | 20.0% | 93.6% |
| [**AXITEC AC-360MH/120V**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-360mh-120v/) AXITEC | 360.0 W | Tie (0 W) | 40.5 V | 19.89% | 92.3% |
| [**AXITEC AC-360MH/120VB**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-360mh-120vb/) AXITEC | 360.0 W | Tie (0 W) | 40.5 V | 19.89% | 93.3% |
| [**Dehui Solar Power (Vietnam) CoLtd DH-M760B 360W**](https://epri-peac.com/solar-equipment/modules/dehui-solar-power-vietnam-coltd/dehui-solar-power-vietnam-coltd-dh-m760b-360w/) Dehui Solar Power (Vietnam) CoLtd | 360.0 W | Tie (0 W) | 40.5 V | 19.67% | 93.3% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for FreeVolt ECP-PVGRAF-120HC-360W Black?

Evaluate FreeVolt ECP-PVGRAF-120HC-360W Black (360.0 W STC, 40.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), FreeVolt ECP-PVGRAF-120HC-360W Black reaches 45.62 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 23 panels for an 8 kW build require 453 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 23 panels (453 sq ft).
- 2026 tax credit baseline: cash residential installs of FreeVolt ECP-PVGRAF-120HC-360W Black carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### FreeVolt ECP-PVGRAF-120HC-360W Black 8 kW Residential Fit

Needs 23 modules (453 sq ft) with a 20 A string OCPD, offsetting ~$2,072/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Apollo Renewables Inc Apollo-M660BH-360BB.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 335.9 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for FreeVolt ECP-PVGRAF-120HC-360W Black by FreeVolt grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for FreeVolt ECP-PVGRAF-120HC-360W Black?

Multiplying FreeVolt ECP-PVGRAF-120HC-360W Black's 11.35 A short-circuit current by 1.56 equals 17.71 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

### Can FreeVolt ECP-PVGRAF-120HC-360W Black pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 44.48 V cold Voc at 14 F and handles 11.35 A Isc; string inverters cap FreeVolt ECP-PVGRAF-120HC-360W Black at 13 panels on 600 V.

### Is FreeVolt ECP-PVGRAF-120HC-360W Black eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of FreeVolt ECP-PVGRAF-120HC-360W Black rely on utility bill offset (~$2,072/yr at 8 kW) rather than 25D.

## Related Pages

Compare FreeVolt equipment, Apollo Renewables Inc Apollo-M660BH-360BB specs, utility payback rates, and NEC string calculators alongside FreeVolt ECP-PVGRAF-120HC-360W Black.

[All FreeVolt Certified Solar Models](https://epri-peac.com/solar-equipment/brands/freevolt/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From FreeVolt

- [All FreeVolt Specs](https://epri-peac.com/solar-equipment/brands/freevolt/)
- [FreeVolt ECP-PVGRAF-HC-BF585-144MT-B](https://epri-peac.com/solar-equipment/modules/freevolt/freevolt-ecp-pvgraf-hc-bf585-144mt-b/)
- [FreeVolt ECP-PVGRAF-HC-BF585-144MT-W](https://epri-peac.com/solar-equipment/modules/freevolt/freevolt-ecp-pvgraf-hc-bf585-144mt-w/)
- [FreeVolt ECP-PVGRAF-HC-BF560-144MT-B](https://epri-peac.com/solar-equipment/modules/freevolt/freevolt-ecp-pvgraf-hc-bf560-144mt-b/)
- [FreeVolt ECP-PVGRAF-HC-BF560-144MT-W](https://epri-peac.com/solar-equipment/modules/freevolt/freevolt-ecp-pvgraf-hc-bf560-144mt-w/)
- [FreeVolt ECP-PVGRAF-144BHC-450W](https://epri-peac.com/solar-equipment/modules/freevolt/freevolt-ecp-pvgraf-144bhc-450w/)