title: "First Solar Inc FS-7545A-FT1 Specs (545.0W, 228.2V Voc)"
url: https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7545a-ft1/
description: "CEC datasheet for First Solar Inc FS-7545A-FT1: 545.0W STC, 228.2V Voc, 15-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# First Solar Inc FS-7545A-FT1 — CEC Solar Module Specifications

Manufacturer: [**First Solar Inc**](https://epri-peac.com/solar-equipment/brands/first-solar-inc/) Registry: **CEC Verified Engineering Specification**

First Solar Inc FS-7545A-FT1 is a 545.0 W STC (507.5 W PTC) CdTe solar module ranking #2,998 of 21,677 CEC listings (top 15.1%; higher than 84.9% of peers). It delivers 19.46% efficiency, 228.2 V Voc at 25 C, and 249.92 V cold Voc at -10 C (2 panels max per 600 V string).

- **STC Wattage** : 545.0 W

- **PTC Wattage** : 507.5 W

- **Voc @ 25C** : 228.2 V

- **Efficiency** : 19.46%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does First Solar Inc FS-7545A-FT1 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for First Solar Inc FS-7545A-FT1 (CdTe) residential solar systems.

First Solar Inc FS-7545A-FT1 delivers 194.6 W/m2 (0.45 percentage points below 19.91% CEC median) and strong 93.1% PTC-to-STC heat retention (#9,420 of 21,677), placing it as a large-format commercial and ground-mount module better matched to wide open ground racks or commercial flat roofs than tight residential roof hips. At -4 F (-20 C), string voltage climbs to 256.13 V per unit, capping 600 V circuits at 2 panels. Compare specs directly with Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8-545 (545.0 W).

## Where Does First Solar Inc FS-7545A-FT1 Fall Across Listed CEC Models?

Comparison of First Solar Inc FS-7545A-FT1 (545.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

## What Dataset Percentiles Define First Solar Inc FS-7545A-FT1?

Relative ranking of First Solar Inc FS-7545A-FT1 across nameplate watts, 93.1% PTC thermal ratio, and module aperture efficiency.

## What Do the Dataset Ranks Show for First Solar Inc FS-7545A-FT1?

Summary of First Solar Inc FS-7545A-FT1 output rank, 8 kW array size (15 panels), efficiency rating, and 600 V string limit.

Rank #2,998 / 21,677

### Top 15.1% STC Output

545.0 W STC (+160.0 W vs all-CEC median) vs 445.0 W CdTe median.

Eff #12,283

### 19.46% Aperture Efficiency

Power density 194.6 W/m2 (0.45 percentage points below 19.91% CEC median). PTC/STC ratio: 93.1% (rank #9,420).

NEC 690.7 Limit

### 2 Panels Max @ -10 C (600 V)

Cold Voc reaches 249.92 V at -10 C (499.8 V string) and 256.13 V at -20 C (2 max).

 8 kW Reference Array

### 15 Panels = 8,175 W STC

Occupies 42.0 m2 (452 sq ft) producing 7,612 W PTC; NEC 690.8 OCPD floor is 4.79 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 228.2 * (1 + (-0.272/100) * (-10 - 25)) = 249.92 V | OCPD = 1.56 * 3.07 = 4.79 A

Inputs from CEC Modules.csv for First Solar Inc FS-7545A-FT1: Voc=228.2 V, beta_Voc=-0.272%/C, Isc=3.07 A, STC=545.0 W, Area=2.8 m2.

**Result:** 2 panels max on 600 V (499.8 V); 15 panels for 8 kW (452 sq ft).

## What Are the Published CEC Specifications for First Solar Inc FS-7545A-FT1?

Complete CEC test sheet for First Solar Inc FS-7545A-FT1 including Isc (3.07 A), Voc (228.2 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for First Solar Inc FS-7545A-FT1.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 545.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 507.5 W (93.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 228.2 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 3.07 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 189.6 V / 2.88 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.272 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 19.46% (2.8 m2) | Array roof footprint density |
| **Cell Count & Technology** | 268 cells (CdTe) | Monofacial backsheet |

## How Many First Solar Inc FS-7545A-FT1 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using First Solar Inc FS-7545A-FT1.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 12 | 6.54 kW | 362 sq ft | $1,637 | $2,768 |
| **8 kW Class** | 15 | 8.18 kW | 452 sq ft | $2,047 | $3,462 |
| **10 kW Class** | 19 | 10.36 kW | 573 sq ft | $2,593 | $4,385 |

## How Many First Solar Inc FS-7545A-FT1 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for First Solar Inc FS-7545A-FT1 (228.2 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=228.2V and beta_Voc=-0.272%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 256.13 V | 2 panels | 512.3 V | 3 panels |
| **-10 C (14 F)** | 249.92 V | 2 panels | 499.8 V | 4 panels |
| **0 C (32 F)** | 243.72 V | 2 panels | 487.4 V | 4 panels |
| **25 C (77 F STC)** | 228.2 V | 2 panels | 456.4 V | 4 panels |

## Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-7545A-FT1?

Four comparable CEC modules such as Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8-545 (545.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8-545**](https://epri-peac.com/solar-equipment/modules/jiangsu-runergy-new-energy-technology-co-ltd/jiangsu-runergy-new-energy-technology-co-ltd-hy-dh144n8-545/) Jiangsu Runergy New Energy Technology Co Ltd | 545.0 W | Tie (0 W) | 50.07 V | 21.12% | 93.8% |
| [**Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8b-545**](https://epri-peac.com/solar-equipment/modules/jiangsu-runergy-new-energy-technology-co-ltd/jiangsu-runergy-new-energy-technology-co-ltd-hy-dh144n8b-545-2/) Jiangsu Runergy New Energy Technology Co Ltd | 545.0 W | Tie (0 W) | 50.07 V | 21.12% | 93.8% |
| [**Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8T-545**](https://epri-peac.com/solar-equipment/modules/jiangsu-runergy-new-energy-technology-co-ltd/jiangsu-runergy-new-energy-technology-co-ltd-hy-dh144n8t-545/) Jiangsu Runergy New Energy Technology Co Ltd | 545.0 W | Tie (0 W) | 50.07 V | 21.12% | 93.8% |
| [**Exiom Solution S A EX550-144MH**](https://epri-peac.com/solar-equipment/modules/exiom-solution-s-a/exiom-solution-s-a-ex550-144mh/) Exiom Solution S A | 545.0 W | Tie (0 W) | 49.8 V | 21.46% | 92.5% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-7545A-FT1?

Evaluate First Solar Inc FS-7545A-FT1 (545.0 W STC, 228.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-7545A-FT1 reaches 256.13 V per panel—exceeding 2 panels in series voids 600 V inverter warranties.
- Footprint constraint: 15 panels for an 8 kW build require 452 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of First Solar Inc FS-7545A-FT1 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### First Solar Inc FS-7545A-FT1 8 kW Residential Fit

Needs 15 modules (452 sq ft) with a 15 A string OCPD, offsetting ~$2,047/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 2 panels (-10 C) or 2 panels (-20 C), or compare Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8-545.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 507.5 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for First Solar Inc FS-7545A-FT1 by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

### How many First Solar Inc FS-7545A-FT1 panels fit on a 600 V winter solar string?

At -10 C (14 F), First Solar Inc FS-7545A-FT1 cold Voc rises from 228.2 V to 249.92 V (beta_Voc -0.272%/C), capping a 600 V string at 2 panels (499.8 V).

### How much roof area does an 8 kW array of First Solar Inc FS-7545A-FT1 need?

An 8 kW DC system uses 15 First Solar Inc FS-7545A-FT1 modules (8,175 W STC / 7,612 W PTC), covering roughly 452 sq ft and saving ~$2,047/yr at 18.54 c/kWh.

### How does First Solar Inc FS-7545A-FT1 compare against Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8-545?

First Solar Inc FS-7545A-FT1 outputs 545.0 W STC (228.2 V Voc, rank #2,998 of 21,677), while Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8-545 delivers 545.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare First Solar Inc equipment, Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8-545 specs, utility payback rates, and NEC string calculators alongside First Solar Inc FS-7545A-FT1.

[All First Solar Inc Certified Solar Models](https://epri-peac.com/solar-equipment/brands/first-solar-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From First Solar Inc

- [All First Solar Inc Specs](https://epri-peac.com/solar-equipment/brands/first-solar-inc/)
- [First Solar Inc FS-7550A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7550a-ft1/)
- [First Solar Inc FS-7550A-TR1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7550a-tr1/)
- [First Solar Inc FS-7545A-TR1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7545a-tr1/)
- [First Solar Inc FS-7540A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7540a-ft1/)
- [First Solar Inc FS-7540A-TR1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7540a-tr1/)