title: "First Solar Inc FS-7540A-TR1 Specs (540.0W, 227.7V Voc)"
url: https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7540a-tr1/
description: "CEC datasheet for First Solar Inc FS-7540A-TR1: 540.0W STC, 227.7V Voc, 15-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# First Solar Inc FS-7540A-TR1 — CEC Solar Module Specifications

Manufacturer: [**First Solar Inc**](https://epri-peac.com/solar-equipment/brands/first-solar-inc/) Registry: **CEC Verified Engineering Specification**

First Solar Inc FS-7540A-TR1 is a 540.0 W STC (502.7 W PTC) CdTe solar module ranking #3,265 of 21,677 CEC listings (top 16.3%; higher than 83.7% of peers). It delivers 19.29% efficiency, 227.7 V Voc at 25 C, and 249.38 V cold Voc at -10 C (2 panels max per 600 V string).

- **STC Wattage** : 540.0 W

- **PTC Wattage** : 502.7 W

- **Voc @ 25C** : 227.7 V

- **Efficiency** : 19.29%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does First Solar Inc FS-7540A-TR1 Compare Against Peer CEC Listings?

How First Solar Inc First Solar Inc FS-7540A-TR1 handles rooftop heat (502.7 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, First Solar Inc FS-7540A-TR1 exhibits 3.06 A short-circuit current, requiring a 4.77 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #3,265 of 21,677 (95.0 W above the 445.0 W CdTe median), this large-format commercial and ground-mount module covers 42.0 m2 for an 8 kW system (19 panels for 10 kW). Higher 227.7 V open-circuit voltage caps 600 V residential strings at 2 panels at 14 F (-10 C).

## Where Does First Solar Inc FS-7540A-TR1 Fall Across Listed CEC Models?

Where First Solar Inc FS-7540A-TR1 (540.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define First Solar Inc FS-7540A-TR1?

Percentile placement of First Solar Inc FS-7540A-TR1 across power density (192.9 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for First Solar Inc FS-7540A-TR1?

Four critical engineering numbers homeowners and solar installers check first when reviewing First Solar Inc FS-7540A-TR1 specifications. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Rank #3,265 / 21,677

### Top 16.3% STC Output

540.0 W STC (+155.0 W vs all-CEC median) vs 445.0 W CdTe median.

Eff #12,743

### 19.29% Aperture Efficiency

Power density 192.9 W/m2 (0.62 percentage points below 19.91% CEC median). PTC/STC ratio: 93.1% (rank #9,420).

NEC 690.7 Limit

### 2 Panels Max @ -10 C (600 V)

Cold Voc reaches 249.38 V at -10 C (498.8 V string) and 255.57 V at -20 C (2 max).

 8 kW Reference Array

### 15 Panels = 8,100 W STC

Occupies 42.0 m2 (452 sq ft) producing 7,540 W PTC; NEC 690.8 OCPD floor is 4.77 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 227.7 * (1 + (-0.272/100) * (-10 - 25)) = 249.38 V | OCPD = 1.56 * 3.06 = 4.77 A

Inputs from CEC Modules.csv for First Solar Inc FS-7540A-TR1: Voc=227.7 V, beta_Voc=-0.272%/C, Isc=3.06 A, STC=540.0 W, Area=2.8 m2.

**Result:** 2 panels max on 600 V (498.8 V); 15 panels for 8 kW (452 sq ft).

## What Are the Published CEC Specifications for First Solar Inc FS-7540A-TR1?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for First Solar Inc FS-7540A-TR1.

Official California Energy Commission (NREL SAM) test parameters for First Solar Inc FS-7540A-TR1.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 540.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 502.7 W (93.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 227.7 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 3.06 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 188.7 V / 2.86 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.272 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 19.29% (2.8 m2) | Array roof footprint density |
| **Cell Count & Technology** | 268 cells (CdTe) | Monofacial backsheet |

## How Many First Solar Inc FS-7540A-TR1 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using First Solar Inc FS-7540A-TR1 (540.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 12 | 6.48 kW | 362 sq ft | $1,622 | $2,742 |
| **8 kW Class** | 15 | 8.1 kW | 452 sq ft | $2,027 | $3,428 |
| **10 kW Class** | 19 | 10.26 kW | 573 sq ft | $2,568 | $4,342 |

## How Many First Solar Inc FS-7540A-TR1 Modules Fit in a Cold-Weather String?

Maximum series module counts for First Solar Inc FS-7540A-TR1 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=227.7V and beta_Voc=-0.272%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 255.57 V | 2 panels | 511.1 V | 3 panels |
| **-10 C (14 F)** | 249.38 V | 2 panels | 498.8 V | 4 panels |
| **0 C (32 F)** | 243.18 V | 2 panels | 486.4 V | 4 panels |
| **25 C (77 F STC)** | 227.7 V | 2 panels | 455.4 V | 4 panels |

## Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-7540A-TR1?

Alternative CEC solar modules from competing brands near First Solar Inc FS-7540A-TR1 (540.0 W), including Auxin Solar AXN10M540B.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Auxin Solar AXN10M540B**](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn10m540b/) Auxin Solar | 540.0 W | Tie (0 W) | 49.65 V | 21.51% | 94.0% |
| [**Auxin Solar AXN10M540W**](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn10m540w/) Auxin Solar | 540.0 W | Tie (0 W) | 49.65 V | 21.51% | 93.5% |
| [**Convalt Manufacturing LLC CVLT540-144MH**](https://epri-peac.com/solar-equipment/modules/convalt-manufacturing-llc/convalt-manufacturing-llc-cvlt540-144mh/) Convalt Manufacturing LLC | 540.0 W | Tie (0 W) | 49.65 V | 21.26% | 92.5% |
| [**AMPS Solar AMPS-540P-72BB**](https://epri-peac.com/solar-equipment/modules/amps-solar/amps-solar-amps-540p-72bb/) AMPS Solar | 540.0 W | Tie (0 W) | 49.6 V | 21.09% | 94.3% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-7540A-TR1?

Evaluate First Solar Inc FS-7540A-TR1 (540.0 W STC, 227.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-7540A-TR1 reaches 255.57 V per panel—exceeding 2 panels in series voids 600 V inverter warranties.
- Footprint constraint: 15 panels for an 8 kW build require 452 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of First Solar Inc FS-7540A-TR1 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### First Solar Inc FS-7540A-TR1 8 kW Residential Fit

Needs 15 modules (452 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 2 panels (-10 C) or 2 panels (-20 C), or compare Auxin Solar AXN10M540B.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 502.7 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for First Solar Inc FS-7540A-TR1 by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is First Solar Inc FS-7540A-TR1 PTC wattage (502.7 W) lower than STC (540.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 502.7 W PTC (93.1% retention) across First Solar Inc FS-7540A-TR1's 2.8 m2 aperture.

### Who should skip First Solar Inc FS-7540A-TR1 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 15 First Solar Inc FS-7540A-TR1 panels (452 sq ft) leave unusable roof gaps vs. Auxin Solar AXN10M540B.

### What is the 1,000 V commercial string limit for First Solar Inc FS-7540A-TR1?

On 1,000 V commercial inverters at -10 C (249.38 V cold Voc), First Solar Inc FS-7540A-TR1 fits up to 4 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting First Solar Inc FS-7540A-TR1.

## Related Pages

Compare First Solar Inc equipment, Auxin Solar AXN10M540B specs, utility payback rates, and NEC string calculators alongside First Solar Inc FS-7540A-TR1.

[All First Solar Inc Certified Solar Models](https://epri-peac.com/solar-equipment/brands/first-solar-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From First Solar Inc

- [All First Solar Inc Specs](https://epri-peac.com/solar-equipment/brands/first-solar-inc/)
- [First Solar Inc FS-7550A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7550a-ft1/)
- [First Solar Inc FS-7550A-TR1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7550a-tr1/)
- [First Solar Inc FS-7545A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7545a-ft1/)
- [First Solar Inc FS-7545A-TR1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7545a-tr1/)
- [First Solar Inc FS-7540A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7540a-ft1/)