First Solar Inc FS-7535A-TR1 is a 535.0 W STC (498.0 W PTC) CdTe solar module ranking #3,537 of 21,677 CEC listings (top 17.5%; higher than 82.5% of peers). It delivers 19.11% efficiency, 227.2 V Voc at 25 C, and 248.83 V cold Voc at -10 C (2 panels max per 600 V string).

- **STC Wattage** : 535.0 W

- **PTC Wattage** : 498.0 W

- **Voc @ 25C** : 227.2 V

- **Efficiency** : 19.11%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does First Solar Inc FS-7535A-TR1 Compare Against Peer CEC Listings?

How First Solar Inc First Solar Inc FS-7535A-TR1 handles rooftop heat (498.0 W PTC), 8 kW sizing, and cold winter string voltage.

First Solar Inc builds the First Solar Inc FS-7535A-TR1 (CdTe) as a large-format commercial and ground-mount module delivering 191.1 W/m2 (0.80 percentage points below 19.91% CEC median). Compared against Boviet Solar Technology Co Ltd BVM7612M-535-H-HC (535.0 W), this model holds strong 93.1% PTC-to-STC heat retention (#9,420 of 21,677). Higher 227.2 V open-circuit voltage caps 600 V residential strings at 2 panels at 14 F (-10 C), while NEC 690.8 sets a 4.77 A overcurrent floor served by a 15 A breaker.

## Where Does First Solar Inc FS-7535A-TR1 Fall Across Listed CEC Models?

Where First Solar Inc FS-7535A-TR1 (535.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define First Solar Inc FS-7535A-TR1?

Percentile placement of First Solar Inc FS-7535A-TR1 across power density (191.1 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for First Solar Inc FS-7535A-TR1?

Four critical engineering numbers homeowners and solar installers check first when reviewing First Solar Inc FS-7535A-TR1 specifications. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Rank #3,537 / 21,677

### Top 17.5% STC Output

535.0 W STC (+150.0 W vs all-CEC median) vs 445.0 W CdTe median.

Eff #13,188

### 19.11% Aperture Efficiency

Power density 191.1 W/m2 (0.80 percentage points below 19.91% CEC median). PTC/STC ratio: 93.1% (rank #9,420).

NEC 690.7 Limit

### 2 Panels Max @ -10 C (600 V)

Cold Voc reaches 248.83 V at -10 C (497.7 V string) and 255.01 V at -20 C (2 max).

 8 kW Reference Array

### 15 Panels = 8,025 W STC

Occupies 42.0 m2 (452 sq ft) producing 7,470 W PTC; NEC 690.8 OCPD floor is 4.77 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 227.2 * (1 + (-0.272/100) * (-10 - 25)) = 248.83 V | OCPD = 1.56 * 3.06 = 4.77 A

Inputs from CEC Modules.csv for First Solar Inc FS-7535A-TR1: Voc=227.2 V, beta_Voc=-0.272%/C, Isc=3.06 A, STC=535.0 W, Area=2.8 m2.

**Result:** 2 panels max on 600 V (497.7 V); 15 panels for 8 kW (452 sq ft).

## What Are the Published CEC Specifications for First Solar Inc FS-7535A-TR1?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for First Solar Inc FS-7535A-TR1.

Official California Energy Commission (NREL SAM) test parameters for First Solar Inc FS-7535A-TR1.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 535.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 498.0 W (93.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 227.2 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 3.06 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 187.8 V / 2.85 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.272 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 19.11% (2.8 m2) | Array roof footprint density |
| **Cell Count & Technology** | 268 cells (CdTe) | Monofacial backsheet |

## How Many First Solar Inc FS-7535A-TR1 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using First Solar Inc FS-7535A-TR1 (535.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 12 | 6.42 kW | 362 sq ft | $1,607 | $2,717 |
| **8 kW Class** | 15 | 8.03 kW | 452 sq ft | $2,010 | $3,398 |
| **10 kW Class** | 19 | 10.16 kW | 573 sq ft | $2,543 | $4,300 |

## How Many First Solar Inc FS-7535A-TR1 Modules Fit in a Cold-Weather String?

Maximum series module counts for First Solar Inc FS-7535A-TR1 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=227.2V and beta_Voc=-0.272%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 255.01 V | 2 panels | 510.0 V | 3 panels |
| **-10 C (14 F)** | 248.83 V | 2 panels | 497.7 V | 4 panels |
| **0 C (32 F)** | 242.65 V | 2 panels | 485.3 V | 4 panels |
| **25 C (77 F STC)** | 227.2 V | 2 panels | 454.4 V | 4 panels |

## Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-7535A-TR1?

Alternative CEC solar modules from competing brands near First Solar Inc FS-7535A-TR1 (535.0 W), including Boviet Solar Technology Co Ltd BVM7612M-535-H-HC.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Boviet Solar Technology Co Ltd BVM7612M-535-H-HC**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7612m-535-h-hc/) Boviet Solar Technology Co Ltd | 535.0 W | Tie (0 W) | 49.8 V | 20.62% | 93.9% |
| [**Chint New Energy Technology Co Ltd CHSM72M-HC-535**](https://epri-peac.com/solar-equipment/modules/chint-new-energy-technology-co-ltd/chint-new-energy-technology-co-ltd-chsm72m-hc-535/) Chint New Energy Technology Co Ltd | 535.0 W | Tie (0 W) | 49.5 V | 21.57% | 92.6% |
| [**Heliene 144HC-535 M10 SL**](https://epri-peac.com/solar-equipment/modules/heliene/heliene-144hc-535-m10-sl/) Heliene | 535.0 W | Tie (0 W) | 49.47 V | 21.49% | 93.5% |
| [**ELITE Solar ET-M772BH535GL**](https://epri-peac.com/solar-equipment/modules/elite-solar/elite-solar-et-m772bh535gl/) ELITE Solar | 535.0 W | Tie (0 W) | 49.45 V | 20.9% | 94.1% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-7535A-TR1?

Evaluate First Solar Inc FS-7535A-TR1 (535.0 W STC, 227.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-7535A-TR1 reaches 255.01 V per panel—exceeding 2 panels in series voids 600 V inverter warranties.
- Footprint constraint: 15 panels for an 8 kW build require 452 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of First Solar Inc FS-7535A-TR1 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### First Solar Inc FS-7535A-TR1 8 kW Residential Fit

Needs 15 modules (452 sq ft) with a 15 A string OCPD, offsetting ~$2,010/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 2 panels (-10 C) or 2 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM7612M-535-H-HC.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 498.0 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for First Solar Inc FS-7535A-TR1 by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for First Solar Inc FS-7535A-TR1?

Multiplying First Solar Inc FS-7535A-TR1's 3.06 A short-circuit current by 1.56 equals 4.77 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

### Can First Solar Inc FS-7535A-TR1 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 248.83 V cold Voc at 14 F and handles 3.06 A Isc; string inverters cap First Solar Inc FS-7535A-TR1 at 2 panels on 600 V.

### Is First Solar Inc FS-7535A-TR1 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of First Solar Inc FS-7535A-TR1 rely on utility bill offset (~$2,010/yr at 8 kW) rather than 25D.

## Related Pages

Compare First Solar Inc equipment, Boviet Solar Technology Co Ltd BVM7612M-535-H-HC specs, utility payback rates, and NEC string calculators alongside First Solar Inc FS-7535A-TR1.

[All First Solar Inc Certified Solar Models](https://epri-peac.com/solar-equipment/brands/first-solar-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From First Solar Inc

- [All First Solar Inc Specs](https://epri-peac.com/solar-equipment/brands/first-solar-inc/)
- [First Solar Inc FS-7550A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7550a-ft1/)
- [First Solar Inc FS-7550A-TR1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7550a-tr1/)
- [First Solar Inc FS-7545A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7545a-ft1/)
- [First Solar Inc FS-7545A-TR1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7545a-tr1/)
- [First Solar Inc FS-7540A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7540a-ft1/)