# First Solar Inc FS-7520A-TR1 — CEC Solar Module Specifications

Manufacturer: [**First Solar Inc**](https://epri-peac.com/solar-equipment/brands/first-solar-inc/) Registry: **CEC Verified Engineering Specification**

First Solar Inc FS-7520A-TR1 is a 520.0 W STC (483.7 W PTC) CdTe solar module ranking #4,199 of 21,677 CEC listings (top 19.9%; higher than 80.1% of peers). It delivers 18.57% efficiency, 225.6 V Voc at 25 C, and 247.08 V cold Voc at -10 C (2 panels max per 600 V string).

- **STC Wattage** : 520.0 W

- **PTC Wattage** : 483.7 W

- **Voc @ 25C** : 225.6 V

- **Efficiency** : 18.57%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does First Solar Inc FS-7520A-TR1 Compare Against Peer CEC Listings?

Solar engineering breakdown for First Solar Inc FS-7520A-TR1: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 520.0 W STC and 483.7 W PTC, First Solar Inc FS-7520A-TR1 sits +135.0 W vs all-CEC median (top 19.9%; higher than 80.1% of peers) among 21,677 listed modules. Power density reaches 185.7 W/m2 (1.34 percentage points below 19.91% CEC median). Higher 225.6 V open-circuit voltage caps 600 V residential strings at 2 panels at 14 F (-10 C), whereas 1,000 V commercial inverters handle up to 4 panels in series. Alternative peer CSI Solar Co Ltd CS3Y-505MS rates 505.0 W.

## Where Does First Solar Inc FS-7520A-TR1 Fall Across Listed CEC Models?

Distribution marker showing First Solar Inc FS-7520A-TR1 (520.0 W) relative to the 385.0 W all-CEC solar panel median.

## What Dataset Percentiles Define First Solar Inc FS-7520A-TR1?

Dataset percentiles tracking First Solar Inc FS-7520A-TR1 power output, thermal retention ratio, and aperture efficiency against 21,677 models.

## What Do the Dataset Ranks Show for First Solar Inc FS-7520A-TR1?

Benchmark highlights for First Solar Inc FS-7520A-TR1 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #4,199 / 21,677

### Top 19.9% STC Output

520.0 W STC (+135.0 W vs all-CEC median) vs 445.0 W CdTe median.

Eff #14,236

### 18.57% Aperture Efficiency

Power density 185.7 W/m2 (1.34 percentage points below 19.91% CEC median). PTC/STC ratio: 93.0% (rank #9,879).

NEC 690.7 Limit

### 2 Panels Max @ -10 C (600 V)

Cold Voc reaches 247.08 V at -10 C (494.2 V string) and 253.21 V at -20 C (2 max).

 8 kW Reference Array

### 16 Panels = 8,320 W STC

Occupies 44.8 m2 (482 sq ft) producing 7,739 W PTC; NEC 690.8 OCPD floor is 4.74 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 225.6 * (1 + (-0.272/100) * (-10 - 25)) = 247.08 V | OCPD = 1.56 * 3.04 = 4.74 A

Inputs from CEC Modules.csv for First Solar Inc FS-7520A-TR1: Voc=225.6 V, beta_Voc=-0.272%/C, Isc=3.04 A, STC=520.0 W, Area=2.8 m2.

**Result:** 2 panels max on 600 V (494.2 V); 16 panels for 8 kW (482 sq ft).

## What Are the Published CEC Specifications for First Solar Inc FS-7520A-TR1?

Official CEC datasheet figures for First Solar Inc FS-7520A-TR1 (CdTe) used in utility interconnection and permit reviews. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Official California Energy Commission (NREL SAM) test parameters for First Solar Inc FS-7520A-TR1.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 520.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 483.7 W (93.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 225.6 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 3.04 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 185.2 V / 2.81 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.272 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 18.57% (2.8 m2) | Array roof footprint density |
| **Cell Count & Technology** | 268 cells (CdTe) | Monofacial backsheet |

## How Many First Solar Inc FS-7520A-TR1 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many First Solar Inc FS-7520A-TR1 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 12 | 6.24 kW | 362 sq ft | $1,562 | $2,641 |
| **8 kW Class** | 16 | 8.32 kW | 482 sq ft | $2,082 | $3,521 |
| **10 kW Class** | 20 | 10.4 kW | 603 sq ft | $2,603 | $4,402 |

## How Many First Solar Inc FS-7520A-TR1 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on First Solar Inc FS-7520A-TR1 (247.08 V at 14 F).

Computed from Voc=225.6V and beta_Voc=-0.272%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 253.21 V | 2 panels | 506.4 V | 3 panels |
| **-10 C (14 F)** | 247.08 V | 2 panels | 494.2 V | 4 panels |
| **0 C (32 F)** | 240.94 V | 2 panels | 481.9 V | 4 panels |
| **25 C (77 F STC)** | 225.6 V | 2 panels | 451.2 V | 4 panels |

## Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-7520A-TR1?

Competing CEC solar panels closest to First Solar Inc FS-7520A-TR1 in nameplate wattage and Voc, starting with CSI Solar Co Ltd CS3Y-505MS.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**CSI Solar Co Ltd CS3Y-505MS**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs3y-505ms/) CSI Solar Co Ltd | 505.0 W | -15.0 W | 53.9 V | 22.05% | 93.7% |
| [**Boviet Solar Technology Co Ltd BVM7612M-520-H-HC**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7612m-520-h-hc/) Boviet Solar Technology Co Ltd | 520.0 W | Tie (0 W) | 49.39 V | 20.04% | 93.8% |
| [**AXITEC AC-520MH/144VB**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-520mh-144vb/) AXITEC | 520.0 W | Tie (0 W) | 49.0 V | 20.31% | 93.7% |
| [**ELITE Solar ET-M772BH520BB**](https://epri-peac.com/solar-equipment/modules/elite-solar/elite-solar-et-m772bh520bb/) ELITE Solar | 520.0 W | Tie (0 W) | 49.0 V | 20.31% | 93.7% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-7520A-TR1?

Evaluate First Solar Inc FS-7520A-TR1 (520.0 W STC, 225.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-7520A-TR1 reaches 253.21 V per panel—exceeding 2 panels in series voids 600 V inverter warranties.
- Footprint constraint: 16 panels for an 8 kW build require 482 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 16 panels (482 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of First Solar Inc FS-7520A-TR1 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### First Solar Inc FS-7520A-TR1 8 kW Residential Fit

Needs 16 modules (482 sq ft) with a 15 A string OCPD, offsetting ~$2,082/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 2 panels (-10 C) or 2 panels (-20 C), or compare CSI Solar Co Ltd CS3Y-505MS.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 483.7 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for First Solar Inc FS-7520A-TR1 by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

### How many First Solar Inc FS-7520A-TR1 panels fit on a 600 V winter solar string?

At -10 C (14 F), First Solar Inc FS-7520A-TR1 cold Voc rises from 225.6 V to 247.08 V (beta_Voc -0.272%/C), capping a 600 V string at 2 panels (494.2 V).

### How much roof area does an 8 kW array of First Solar Inc FS-7520A-TR1 need?

An 8 kW DC system uses 16 First Solar Inc FS-7520A-TR1 modules (8,320 W STC / 7,739 W PTC), covering roughly 482 sq ft and saving ~$2,082/yr at 18.54 c/kWh.

### How does First Solar Inc FS-7520A-TR1 compare against CSI Solar Co Ltd CS3Y-505MS?

First Solar Inc FS-7520A-TR1 outputs 520.0 W STC (225.6 V Voc, rank #4,199 of 21,677), while CSI Solar Co Ltd CS3Y-505MS delivers 505.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare First Solar Inc equipment, CSI Solar Co Ltd CS3Y-505MS specs, utility payback rates, and NEC string calculators alongside First Solar Inc FS-7520A-TR1.

[All First Solar Inc Certified Solar Models](https://epri-peac.com/solar-equipment/brands/first-solar-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From First Solar Inc

- [All First Solar Inc Specs](https://epri-peac.com/solar-equipment/brands/first-solar-inc/)
- [First Solar Inc FS-7550A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7550a-ft1/)
- [First Solar Inc FS-7550A-TR1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7550a-tr1/)
- [First Solar Inc FS-7545A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7545a-ft1/)
- [First Solar Inc FS-7545A-TR1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7545a-tr1/)
- [First Solar Inc FS-7540A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7540a-ft1/)