title: "First Solar Inc FS-6485A-P-I Specs (485.0W, 225.9V Voc)"
url: https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-6485a-p-i/
description: "CEC datasheet for First Solar Inc FS-6485A-P-I: 485.0W STC, 225.9V Voc, 17-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# First Solar Inc FS-6485A-P-I — CEC Solar Module Specifications

Manufacturer: [**First Solar Inc**](https://epri-peac.com/solar-equipment/brands/first-solar-inc/) Registry: **CEC Verified Engineering Specification**

First Solar Inc FS-6485A-P-I is a 485.0 W STC (457.1 W PTC) CdTe solar module ranking #4,730 of 21,677 CEC listings (top 22.2%; higher than 77.8% of peers). It delivers 19.25% efficiency, 225.9 V Voc at 25 C, and 247.8 V cold Voc at -10 C (2 panels max per 600 V string).

- **STC Wattage** : 485.0 W

- **PTC Wattage** : 457.1 W

- **Voc @ 25C** : 225.9 V

- **Efficiency** : 19.25%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does First Solar Inc FS-6485A-P-I Compare Against Peer CEC Listings?

Solar engineering breakdown for First Solar Inc FS-6485A-P-I: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 485.0 W STC and 457.1 W PTC, First Solar Inc FS-6485A-P-I sits +100.0 W vs all-CEC median (top 22.2%; higher than 77.8% of peers) among 21,677 listed modules. Power density reaches 192.5 W/m2 (0.66 percentage points below 19.91% CEC median). Higher 225.9 V open-circuit voltage caps 600 V residential strings at 2 panels at 14 F (-10 C), whereas 1,000 V commercial inverters handle up to 4 panels in series. Alternative peer Applied Materials Full Size Tandem Junction rates 458.0 W.

## Where Does First Solar Inc FS-6485A-P-I Fall Across Listed CEC Models?

Distribution marker showing First Solar Inc FS-6485A-P-I (485.0 W) relative to the 385.0 W all-CEC solar panel median.

## What Dataset Percentiles Define First Solar Inc FS-6485A-P-I?

Dataset percentiles tracking First Solar Inc FS-6485A-P-I power output, thermal retention ratio, and aperture efficiency against 21,677 models.

## What Do the Dataset Ranks Show for First Solar Inc FS-6485A-P-I?

Benchmark highlights for First Solar Inc FS-6485A-P-I covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #4,730 / 21,677

### Top 22.2% STC Output

485.0 W STC (+100.0 W vs all-CEC median) vs 445.0 W CdTe median.

Eff #12,863

### 19.25% Aperture Efficiency

Power density 192.5 W/m2 (0.66 percentage points below 19.91% CEC median). PTC/STC ratio: 94.2% (rank #3,689).

NEC 690.7 Limit

### 2 Panels Max @ -10 C (600 V)

Cold Voc reaches 247.8 V at -10 C (495.6 V string) and 254.06 V at -20 C (2 max).

 8 kW Reference Array

### 17 Panels = 8,245 W STC

Occupies 42.8 m2 (461 sq ft) producing 7,771 W PTC; NEC 690.8 OCPD floor is 4.09 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 225.9 * (1 + (-0.277/100) * (-10 - 25)) = 247.8 V | OCPD = 1.56 * 2.62 = 4.09 A

Inputs from CEC Modules.csv for First Solar Inc FS-6485A-P-I: Voc=225.9 V, beta_Voc=-0.277%/C, Isc=2.62 A, STC=485.0 W, Area=2.52 m2.

**Result:** 2 panels max on 600 V (495.6 V); 17 panels for 8 kW (461 sq ft).

## What Are the Published CEC Specifications for First Solar Inc FS-6485A-P-I?

Official CEC datasheet figures for First Solar Inc FS-6485A-P-I (CdTe) used in utility interconnection and permit reviews. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Official California Energy Commission (NREL SAM) test parameters for First Solar Inc FS-6485A-P-I.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 485.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 457.1 W (94.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 225.9 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 2.62 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 194.0 V / 2.5 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.277 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 19.25% (2.52 m2) | Array roof footprint density |
| **Cell Count & Technology** | 268 cells (CdTe) | Monofacial backsheet |

## How Many First Solar Inc FS-6485A-P-I Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many First Solar Inc FS-6485A-P-I modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 13 | 6.3 kW | 353 sq ft | $1,577 | $2,666 |
| **8 kW Class** | 17 | 8.24 kW | 461 sq ft | $2,062 | $3,487 |
| **10 kW Class** | 21 | 10.19 kW | 570 sq ft | $2,550 | $4,313 |

## How Many First Solar Inc FS-6485A-P-I Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on First Solar Inc FS-6485A-P-I (247.8 V at 14 F).

Computed from Voc=225.9V and beta_Voc=-0.277%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 254.06 V | 2 panels | 508.1 V | 3 panels |
| **-10 C (14 F)** | 247.8 V | 2 panels | 495.6 V | 4 panels |
| **0 C (32 F)** | 241.54 V | 2 panels | 483.1 V | 4 panels |
| **25 C (77 F STC)** | 225.9 V | 2 panels | 451.8 V | 4 panels |

## Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-6485A-P-I?

Competing CEC solar panels closest to First Solar Inc FS-6485A-P-I in nameplate wattage and Voc, starting with Applied Materials Full Size Tandem Junction.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Applied Materials Full Size Tandem Junction**](https://epri-peac.com/solar-equipment/modules/applied-materials/applied-materials-full-size-tandem-junction/) Applied Materials | 458.0 W | -27.0 W | 280.0 V | 8.01% | 91.7% |
| [**Heliene 96M475**](https://epri-peac.com/solar-equipment/modules/heliene/heliene-96m475/) Heliene | 475.0 W | -10.0 W | 62.39 V | 18.85% | 90.5% |
| [**Heliene 96M460**](https://epri-peac.com/solar-equipment/modules/heliene/heliene-96m460/) Heliene | 460.0 W | -25.0 W | 61.79 V | 18.25% | 90.4% |
| [**CSI Solar Co Ltd CS3Y-485MS**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs3y-485ms/) CSI Solar Co Ltd | 485.0 W | Tie (0 W) | 53.1 V | 21.18% | 93.6% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-6485A-P-I?

Evaluate First Solar Inc FS-6485A-P-I (485.0 W STC, 225.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-6485A-P-I reaches 254.06 V per panel—exceeding 2 panels in series voids 600 V inverter warranties.
- Footprint constraint: 17 panels for an 8 kW build require 461 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 17 panels (461 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of First Solar Inc FS-6485A-P-I carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### First Solar Inc FS-6485A-P-I 8 kW Residential Fit

Needs 17 modules (461 sq ft) with a 15 A string OCPD, offsetting ~$2,062/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 2 panels (-10 C) or 2 panels (-20 C), or compare Applied Materials Full Size Tandem Junction.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 457.1 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for First Solar Inc FS-6485A-P-I by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

### How many First Solar Inc FS-6485A-P-I panels fit on a 600 V winter solar string?

At -10 C (14 F), First Solar Inc FS-6485A-P-I cold Voc rises from 225.9 V to 247.8 V (beta_Voc -0.277%/C), capping a 600 V string at 2 panels (495.6 V).

### How much roof area does an 8 kW array of First Solar Inc FS-6485A-P-I need?

An 8 kW DC system uses 17 First Solar Inc FS-6485A-P-I modules (8,245 W STC / 7,771 W PTC), covering roughly 461 sq ft and saving ~$2,062/yr at 18.54 c/kWh.

### How does First Solar Inc FS-6485A-P-I compare against Applied Materials Full Size Tandem Junction?

First Solar Inc FS-6485A-P-I outputs 485.0 W STC (225.9 V Voc, rank #4,730 of 21,677), while Applied Materials Full Size Tandem Junction delivers 458.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare First Solar Inc equipment, Applied Materials Full Size Tandem Junction specs, utility payback rates, and NEC string calculators alongside First Solar Inc FS-6485A-P-I.

[All First Solar Inc Certified Solar Models](https://epri-peac.com/solar-equipment/brands/first-solar-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From First Solar Inc

- [All First Solar Inc Specs](https://epri-peac.com/solar-equipment/brands/first-solar-inc/)
- [First Solar Inc FS-7550A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7550a-ft1/)
- [First Solar Inc FS-7550A-TR1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7550a-tr1/)
- [First Solar Inc FS-7545A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7545a-ft1/)
- [First Solar Inc FS-7545A-TR1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7545a-tr1/)
- [First Solar Inc FS-7540A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7540a-ft1/)