# First Solar Inc FS-6480A-P — CEC Solar Module Specifications

Manufacturer: [**First Solar Inc**](https://epri-peac.com/solar-equipment/brands/first-solar-inc/) Registry: **CEC Verified Engineering Specification**

First Solar Inc FS-6480A-P is a 480.0 W STC (452.3 W PTC) CdTe solar module ranking #4,809 of 21,677 CEC listings (top 22.6%; higher than 77.4% of peers). It delivers 19.05% efficiency, 225.4 V Voc at 25 C, and 247.25 V cold Voc at -10 C (2 panels max per 600 V string).

- **STC Wattage** : 480.0 W

- **PTC Wattage** : 452.3 W

- **Voc @ 25C** : 225.4 V

- **Efficiency** : 19.05%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does First Solar Inc FS-6480A-P Compare Against Peer CEC Listings?

Engineering position of First Solar Inc FS-6480A-P (480.0 W STC) vs. Applied Materials Full Size Tandem Junction across 131 CEC CdTe solar modules.

Ranking #4,809 across 21,677 CEC solar panels (top 22.6%; higher than 77.4% of peers), First Solar Inc FS-6480A-P operates as a modern high-density residential and light-commercial module sitting 35.0 W above the 445.0 W CdTe median. Higher 225.4 V open-circuit voltage caps 600 V residential strings at 2 panels at 14 F (-10 C). With strong 94.2% PTC-to-STC heat retention (#3,689 of 21,677), 17 panels occupy 461 sq ft and offset roughly $2,042/yr at average US rates (or $3,454/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

## Where Does First Solar Inc FS-6480A-P Fall Across Listed CEC Models?

Plots First Solar Inc FS-6480A-P at 480.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

## What Dataset Percentiles Define First Solar Inc FS-6480A-P?

Benchmarks First Solar Inc FS-6480A-P on STC wattage, thermal PTC/STC retention, and 19.05 aperture conversion efficiency against CEC peers.

## What Do the Dataset Ranks Show for First Solar Inc FS-6480A-P?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for First Solar Inc FS-6480A-P by First Solar Inc.

Rank #4,809 / 21,677

### Top 22.6% STC Output

480.0 W STC (+95.0 W vs all-CEC median) vs 445.0 W CdTe median.

Eff #13,319

### 19.05% Aperture Efficiency

Power density 190.5 W/m2 (0.86 percentage points below 19.91% CEC median). PTC/STC ratio: 94.2% (rank #3,689).

NEC 690.7 Limit

### 2 Panels Max @ -10 C (600 V)

Cold Voc reaches 247.25 V at -10 C (494.5 V string) and 253.5 V at -20 C (2 max).

 8 kW Reference Array

### 17 Panels = 8,160 W STC

Occupies 42.8 m2 (461 sq ft) producing 7,689 W PTC; NEC 690.8 OCPD floor is 4.09 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 225.4 * (1 + (-0.277/100) * (-10 - 25)) = 247.25 V | OCPD = 1.56 * 2.62 = 4.09 A

Inputs from CEC Modules.csv for First Solar Inc FS-6480A-P: Voc=225.4 V, beta_Voc=-0.277%/C, Isc=2.62 A, STC=480.0 W, Area=2.52 m2.

**Result:** 2 panels max on 600 V (494.5 V); 17 panels for 8 kW (461 sq ft).

## What Are the Published CEC Specifications for First Solar Inc FS-6480A-P?

Laboratory test ratings recorded for First Solar Inc FS-6480A-P (CdTe) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for First Solar Inc FS-6480A-P.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 480.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 452.3 W (94.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 225.4 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 2.62 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 192.8 V / 2.49 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.277 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 19.05% (2.52 m2) | Array roof footprint density |
| **Cell Count & Technology** | 268 cells (CdTe) | Monofacial backsheet |

## How Many First Solar Inc FS-6480A-P Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (461 sq ft at 8 kW), and estimated Year-1 electric bill offset for First Solar Inc FS-6480A-P.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 13 | 6.24 kW | 353 sq ft | $1,562 | $2,641 |
| **8 kW Class** | 17 | 8.16 kW | 461 sq ft | $2,042 | $3,454 |
| **10 kW Class** | 21 | 10.08 kW | 570 sq ft | $2,523 | $4,266 |

## How Many First Solar Inc FS-6480A-P Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for First Solar Inc FS-6480A-P (beta_Voc -0.277%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=225.4V and beta_Voc=-0.277%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 253.5 V | 2 panels | 507.0 V | 3 panels |
| **-10 C (14 F)** | 247.25 V | 2 panels | 494.5 V | 4 panels |
| **0 C (32 F)** | 241.01 V | 2 panels | 482.0 V | 4 panels |
| **25 C (77 F STC)** | 225.4 V | 2 panels | 450.8 V | 4 panels |

## Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-6480A-P?

Closest cross-brand CEC competitors to First Solar Inc FS-6480A-P matched near 480.0 W STC and 225.4 V Voc, led by Applied Materials Full Size Tandem Junction.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Applied Materials Full Size Tandem Junction**](https://epri-peac.com/solar-equipment/modules/applied-materials/applied-materials-full-size-tandem-junction/) Applied Materials | 458.0 W | -22.0 W | 280.0 V | 8.01% | 91.7% |
| [**Heliene 96M475**](https://epri-peac.com/solar-equipment/modules/heliene/heliene-96m475/) Heliene | 475.0 W | -5.0 W | 62.39 V | 18.85% | 90.5% |
| [**Heliene 96M460**](https://epri-peac.com/solar-equipment/modules/heliene/heliene-96m460/) Heliene | 460.0 W | -20.0 W | 61.79 V | 18.25% | 90.4% |
| [**CSI Solar Co Ltd CS3Y-480P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs3y-480p/) CSI Solar Co Ltd | 480.0 W | Tie (0 W) | 52.8 V | 20.96% | 93.2% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-6480A-P?

Evaluate First Solar Inc FS-6480A-P (480.0 W STC, 225.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-6480A-P reaches 253.5 V per panel—exceeding 2 panels in series voids 600 V inverter warranties.
- Footprint constraint: 17 panels for an 8 kW build require 461 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 17 panels (461 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of First Solar Inc FS-6480A-P carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### First Solar Inc FS-6480A-P 8 kW Residential Fit

Needs 17 modules (461 sq ft) with a 15 A string OCPD, offsetting ~$2,042/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 2 panels (-10 C) or 2 panels (-20 C), or compare Applied Materials Full Size Tandem Junction.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 452.3 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for First Solar Inc FS-6480A-P by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

### How many First Solar Inc FS-6480A-P panels fit on a 600 V winter solar string?

At -10 C (14 F), First Solar Inc FS-6480A-P cold Voc rises from 225.4 V to 247.25 V (beta_Voc -0.277%/C), capping a 600 V string at 2 panels (494.5 V).

### How much roof area does an 8 kW array of First Solar Inc FS-6480A-P need?

An 8 kW DC system uses 17 First Solar Inc FS-6480A-P modules (8,160 W STC / 7,689 W PTC), covering roughly 461 sq ft and saving ~$2,042/yr at 18.54 c/kWh.

### How does First Solar Inc FS-6480A-P compare against Applied Materials Full Size Tandem Junction?

First Solar Inc FS-6480A-P outputs 480.0 W STC (225.4 V Voc, rank #4,809 of 21,677), while Applied Materials Full Size Tandem Junction delivers 458.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare First Solar Inc equipment, Applied Materials Full Size Tandem Junction specs, utility payback rates, and NEC string calculators alongside First Solar Inc FS-6480A-P.

[All First Solar Inc Certified Solar Models](https://epri-peac.com/solar-equipment/brands/first-solar-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From First Solar Inc

- [All First Solar Inc Specs](https://epri-peac.com/solar-equipment/brands/first-solar-inc/)
- [First Solar Inc FS-7550A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7550a-ft1/)
- [First Solar Inc FS-7550A-TR1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7550a-tr1/)
- [First Solar Inc FS-7545A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7545a-ft1/)
- [First Solar Inc FS-7545A-TR1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7545a-tr1/)
- [First Solar Inc FS-7540A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7540a-ft1/)