title: "First Solar Inc FS-6470A-P Specs (470.0W, 224.3V Voc)"
url: https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-6470a-p/
description: "CEC datasheet for First Solar Inc FS-6470A-P: 470.0W STC, 224.3V Voc, 18-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# First Solar Inc FS-6470A-P — CEC Solar Module Specifications

Manufacturer: [**First Solar Inc**](https://epri-peac.com/solar-equipment/brands/first-solar-inc/) Registry: **CEC Verified Engineering Specification**

First Solar Inc FS-6470A-P is a 470.0 W STC (442.7 W PTC) CdTe solar module ranking #4,967 of 21,677 CEC listings (top 23.4%; higher than 76.6% of peers). It delivers 18.65% efficiency, 224.3 V Voc at 25 C, and 246.05 V cold Voc at -10 C (2 panels max per 600 V string).

- **STC Wattage** : 470.0 W

- **PTC Wattage** : 442.7 W

- **Voc @ 25C** : 224.3 V

- **Efficiency** : 18.65%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does First Solar Inc FS-6470A-P Compare Against Peer CEC Listings?

Solar engineering breakdown for First Solar Inc FS-6470A-P: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 131 CdTe listings from First Solar Inc and peers, First Solar Inc FS-6470A-P stands 25.0 W above the 445.0 W CdTe median and strong 94.2% PTC-to-STC heat retention (#3,689 of 21,677). Sizing 6 kW (13 panels) to 10 kW (22 panels) yields $1,529-$2,588/yr in baseline US bill offset. Higher 224.3 V open-circuit voltage caps 600 V residential strings at 2 panels at 14 F (-10 C).

## Where Does First Solar Inc FS-6470A-P Fall Across Listed CEC Models?

Distribution marker showing First Solar Inc FS-6470A-P (470.0 W) relative to the 385.0 W all-CEC solar panel median.

## What Dataset Percentiles Define First Solar Inc FS-6470A-P?

Dataset percentiles tracking First Solar Inc FS-6470A-P power output, thermal retention ratio, and aperture efficiency against 21,677 models.

## What Do the Dataset Ranks Show for First Solar Inc FS-6470A-P?

Benchmark highlights for First Solar Inc FS-6470A-P covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #4,967 / 21,677

### Top 23.4% STC Output

470.0 W STC (+85.0 W vs all-CEC median) vs 445.0 W CdTe median.

Eff #14,111

### 18.65% Aperture Efficiency

Power density 186.5 W/m2 (1.26 percentage points below 19.91% CEC median). PTC/STC ratio: 94.2% (rank #3,689).

NEC 690.7 Limit

### 2 Panels Max @ -10 C (600 V)

Cold Voc reaches 246.05 V at -10 C (492.1 V string) and 252.26 V at -20 C (2 max).

 8 kW Reference Array

### 18 Panels = 8,460 W STC

Occupies 45.4 m2 (488 sq ft) producing 7,969 W PTC; NEC 690.8 OCPD floor is 4.07 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 224.3 * (1 + (-0.277/100) * (-10 - 25)) = 246.05 V | OCPD = 1.56 * 2.61 = 4.07 A

Inputs from CEC Modules.csv for First Solar Inc FS-6470A-P: Voc=224.3 V, beta_Voc=-0.277%/C, Isc=2.61 A, STC=470.0 W, Area=2.52 m2.

**Result:** 2 panels max on 600 V (492.1 V); 18 panels for 8 kW (488 sq ft).

## What Are the Published CEC Specifications for First Solar Inc FS-6470A-P?

Official CEC datasheet figures for First Solar Inc FS-6470A-P (CdTe) used in utility interconnection and permit reviews. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Official California Energy Commission (NREL SAM) test parameters for First Solar Inc FS-6470A-P.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 470.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 442.7 W (94.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 224.3 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 2.61 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 191.1 V / 2.46 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.277 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 18.65% (2.52 m2) | Array roof footprint density |
| **Cell Count & Technology** | 268 cells (CdTe) | Monofacial backsheet |

## How Many First Solar Inc FS-6470A-P Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many First Solar Inc FS-6470A-P modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 13 | 6.11 kW | 353 sq ft | $1,529 | $2,586 |
| **8 kW Class** | 18 | 8.46 kW | 488 sq ft | $2,117 | $3,580 |
| **10 kW Class** | 22 | 10.34 kW | 597 sq ft | $2,588 | $4,376 |

## How Many First Solar Inc FS-6470A-P Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on First Solar Inc FS-6470A-P (246.05 V at 14 F).

Computed from Voc=224.3V and beta_Voc=-0.277%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 252.26 V | 2 panels | 504.5 V | 3 panels |
| **-10 C (14 F)** | 246.05 V | 2 panels | 492.1 V | 4 panels |
| **0 C (32 F)** | 239.83 V | 2 panels | 479.7 V | 4 panels |
| **25 C (77 F STC)** | 224.3 V | 2 panels | 448.6 V | 4 panels |

## Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-6470A-P?

Competing CEC solar panels closest to First Solar Inc FS-6470A-P in nameplate wattage and Voc, starting with Applied Materials Full Size Tandem Junction.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Applied Materials Full Size Tandem Junction**](https://epri-peac.com/solar-equipment/modules/applied-materials/applied-materials-full-size-tandem-junction/) Applied Materials | 458.0 W | -12.0 W | 280.0 V | 8.01% | 91.7% |
| [**Heliene 96M475**](https://epri-peac.com/solar-equipment/modules/heliene/heliene-96m475/) Heliene | 475.0 W | +5.0 W | 62.39 V | 18.85% | 90.5% |
| [**Heliene 96M460**](https://epri-peac.com/solar-equipment/modules/heliene/heliene-96m460/) Heliene | 460.0 W | -10.0 W | 61.79 V | 18.25% | 90.4% |
| [**CSI Solar Co Ltd CS3Y-470MS**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs3y-470ms/) CSI Solar Co Ltd | 470.0 W | Tie (0 W) | 52.5 V | 20.52% | 93.5% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-6470A-P?

Evaluate First Solar Inc FS-6470A-P (470.0 W STC, 224.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-6470A-P reaches 252.26 V per panel—exceeding 2 panels in series voids 600 V inverter warranties.
- Footprint constraint: 18 panels for an 8 kW build require 488 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (488 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of First Solar Inc FS-6470A-P carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### First Solar Inc FS-6470A-P 8 kW Residential Fit

Needs 18 modules (488 sq ft) with a 15 A string OCPD, offsetting ~$2,117/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 2 panels (-10 C) or 2 panels (-20 C), or compare Applied Materials Full Size Tandem Junction.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 442.7 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for First Solar Inc FS-6470A-P by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for First Solar Inc FS-6470A-P?

Multiplying First Solar Inc FS-6470A-P's 2.61 A short-circuit current by 1.56 equals 4.07 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

### Can First Solar Inc FS-6470A-P pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 246.05 V cold Voc at 14 F and handles 2.61 A Isc; string inverters cap First Solar Inc FS-6470A-P at 2 panels on 600 V.

### Is First Solar Inc FS-6470A-P eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of First Solar Inc FS-6470A-P rely on utility bill offset (~$2,117/yr at 8 kW) rather than 25D.

## Related Pages

Compare First Solar Inc equipment, Applied Materials Full Size Tandem Junction specs, utility payback rates, and NEC string calculators alongside First Solar Inc FS-6470A-P.

[All First Solar Inc Certified Solar Models](https://epri-peac.com/solar-equipment/brands/first-solar-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From First Solar Inc

- [All First Solar Inc Specs](https://epri-peac.com/solar-equipment/brands/first-solar-inc/)
- [First Solar Inc FS-7550A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7550a-ft1/)
- [First Solar Inc FS-7550A-TR1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7550a-tr1/)
- [First Solar Inc FS-7545A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7545a-ft1/)
- [First Solar Inc FS-7545A-TR1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7545a-tr1/)
- [First Solar Inc FS-7540A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7540a-ft1/)