---
title: "First Solar Inc FS-6470A-P-I Specs (470.0W, 224.3V Voc)"
url: https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-6470a-p-i/
description: "CEC datasheet for First Solar Inc FS-6470A-P-I: 470.0W STC, 224.3V Voc, 18-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# First Solar Inc FS-6470A-P-I — CEC Solar Module Specifications

Manufacturer: [**First Solar Inc**](https://epri-peac.com/solar-equipment/brands/first-solar-inc/) Registry: **CEC Verified Engineering Specification**

First Solar Inc FS-6470A-P-I is a 470.0 W STC (442.7 W PTC) CdTe solar module ranking #4,967 of 21,677 CEC listings (top 23.4%; higher than 76.6% of peers). It delivers 18.65% efficiency, 224.3 V Voc at 25 C, and 246.05 V cold Voc at -10 C (2 panels max per 600 V string).

- **STC Wattage** : 470.0 W

- **PTC Wattage** : 442.7 W

- **Voc @ 25C** : 224.3 V

- **Efficiency** : 18.65%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does First Solar Inc FS-6470A-P-I Compare Against Peer CEC Listings?

How First Solar Inc First Solar Inc FS-6470A-P-I handles rooftop heat (442.7 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, First Solar Inc FS-6470A-P-I exhibits 2.61 A short-circuit current, requiring a 4.07 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #4,967 of 21,677 (25.0 W above the 445.0 W CdTe median), this modern high-density residential and light-commercial module covers 45.4 m2 for an 8 kW system (22 panels for 10 kW). Higher 224.3 V open-circuit voltage caps 600 V residential strings at 2 panels at 14 F (-10 C).

## Where Does First Solar Inc FS-6470A-P-I Fall Across Listed CEC Models?

Where First Solar Inc FS-6470A-P-I (470.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define First Solar Inc FS-6470A-P-I?

Percentile placement of First Solar Inc FS-6470A-P-I across power density (186.5 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for First Solar Inc FS-6470A-P-I?

Four critical engineering numbers homeowners and solar installers check first when reviewing First Solar Inc FS-6470A-P-I specifications. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Rank #4,967 / 21,677

### Top 23.4% STC Output

470.0 W STC (+85.0 W vs all-CEC median) vs 445.0 W CdTe median.

Eff #14,111

### 18.65% Aperture Efficiency

Power density 186.5 W/m2 (1.26 percentage points below 19.91% CEC median). PTC/STC ratio: 94.2% (rank #3,689).

NEC 690.7 Limit

### 2 Panels Max @ -10 C (600 V)

Cold Voc reaches 246.05 V at -10 C (492.1 V string) and 252.26 V at -20 C (2 max).

 8 kW Reference Array

### 18 Panels = 8,460 W STC

Occupies 45.4 m2 (488 sq ft) producing 7,969 W PTC; NEC 690.8 OCPD floor is 4.07 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 224.3 * (1 + (-0.277/100) * (-10 - 25)) = 246.05 V | OCPD = 1.56 * 2.61 = 4.07 A

Inputs from CEC Modules.csv for First Solar Inc FS-6470A-P-I: Voc=224.3 V, beta_Voc=-0.277%/C, Isc=2.61 A, STC=470.0 W, Area=2.52 m2.

**Result:** 2 panels max on 600 V (492.1 V); 18 panels for 8 kW (488 sq ft).

## What Are the Published CEC Specifications for First Solar Inc FS-6470A-P-I?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for First Solar Inc FS-6470A-P-I.

Official California Energy Commission (NREL SAM) test parameters for First Solar Inc FS-6470A-P-I.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 470.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 442.7 W (94.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 224.3 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 2.61 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 191.1 V / 2.46 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.277 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 18.65% (2.52 m2) | Array roof footprint density |
| **Cell Count & Technology** | 268 cells (CdTe) | Monofacial backsheet |

## How Many First Solar Inc FS-6470A-P-I Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using First Solar Inc FS-6470A-P-I (470.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 13 | 6.11 kW | 353 sq ft | $1,529 | $2,586 |
| **8 kW Class** | 18 | 8.46 kW | 488 sq ft | $2,117 | $3,580 |
| **10 kW Class** | 22 | 10.34 kW | 597 sq ft | $2,588 | $4,376 |

## How Many First Solar Inc FS-6470A-P-I Modules Fit in a Cold-Weather String?

Maximum series module counts for First Solar Inc FS-6470A-P-I from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=224.3V and beta_Voc=-0.277%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 252.26 V | 2 panels | 504.5 V | 3 panels |
| **-10 C (14 F)** | 246.05 V | 2 panels | 492.1 V | 4 panels |
| **0 C (32 F)** | 239.83 V | 2 panels | 479.7 V | 4 panels |
| **25 C (77 F STC)** | 224.3 V | 2 panels | 448.6 V | 4 panels |

## Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-6470A-P-I?

Alternative CEC solar modules from competing brands near First Solar Inc FS-6470A-P-I (470.0 W), including Applied Materials Full Size Tandem Junction.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Applied Materials Full Size Tandem Junction**](https://epri-peac.com/solar-equipment/modules/applied-materials/applied-materials-full-size-tandem-junction/) Applied Materials | 458.0 W | -12.0 W | 280.0 V | 8.01% | 91.7% |
| [**Heliene 96M475**](https://epri-peac.com/solar-equipment/modules/heliene/heliene-96m475/) Heliene | 475.0 W | +5.0 W | 62.39 V | 18.85% | 90.5% |
| [**Heliene 96M460**](https://epri-peac.com/solar-equipment/modules/heliene/heliene-96m460/) Heliene | 460.0 W | -10.0 W | 61.79 V | 18.25% | 90.4% |
| [**CSI Solar Co Ltd CS3Y-470MS**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs3y-470ms/) CSI Solar Co Ltd | 470.0 W | Tie (0 W) | 52.5 V | 20.52% | 93.5% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-6470A-P-I?

Evaluate First Solar Inc FS-6470A-P-I (470.0 W STC, 224.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-6470A-P-I reaches 252.26 V per panel—exceeding 2 panels in series voids 600 V inverter warranties.
- Footprint constraint: 18 panels for an 8 kW build require 488 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (488 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of First Solar Inc FS-6470A-P-I carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### First Solar Inc FS-6470A-P-I 8 kW Residential Fit

Needs 18 modules (488 sq ft) with a 15 A string OCPD, offsetting ~$2,117/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 2 panels (-10 C) or 2 panels (-20 C), or compare Applied Materials Full Size Tandem Junction.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 442.7 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for First Solar Inc FS-6470A-P-I by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is First Solar Inc FS-6470A-P-I PTC wattage (442.7 W) lower than STC (470.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 442.7 W PTC (94.2% retention) across First Solar Inc FS-6470A-P-I's 2.52 m2 aperture.

### Who should skip First Solar Inc FS-6470A-P-I on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 18 First Solar Inc FS-6470A-P-I panels (488 sq ft) leave unusable roof gaps vs. Applied Materials Full Size Tandem Junction.

### What is the 1,000 V commercial string limit for First Solar Inc FS-6470A-P-I?

On 1,000 V commercial inverters at -10 C (246.05 V cold Voc), First Solar Inc FS-6470A-P-I fits up to 4 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting First Solar Inc FS-6470A-P-I.

## Related Pages

Compare First Solar Inc equipment, Applied Materials Full Size Tandem Junction specs, utility payback rates, and NEC string calculators alongside First Solar Inc FS-6470A-P-I.

[All First Solar Inc Certified Solar Models](https://epri-peac.com/solar-equipment/brands/first-solar-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From First Solar Inc

- [All First Solar Inc Specs](https://epri-peac.com/solar-equipment/brands/first-solar-inc/)
- [First Solar Inc FS-7550A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7550a-ft1/)
- [First Solar Inc FS-7550A-TR1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7550a-tr1/)
- [First Solar Inc FS-7545A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7545a-ft1/)
- [First Solar Inc FS-7545A-TR1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7545a-tr1/)
- [First Solar Inc FS-7540A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7540a-ft1/)
