Manufacturer: [**First Solar Inc**](https://epri-peac.com/solar-equipment/brands/first-solar-inc/) Registry: **CEC Verified Engineering Specification**

First Solar Inc FS-6455-P-B is a 455.0 W STC (421.2 W PTC) CdTe solar module ranking #5,417 of 21,677 CEC listings (top 26.2%; higher than 73.8% of peers). It delivers 18.06% efficiency, 222.0 V Voc at 25 C, and 243.06 V cold Voc at -10 C (2 panels max per 600 V string).

- **STC Wattage** : 455.0 W

- **PTC Wattage** : 421.2 W

- **Voc @ 25C** : 222.0 V

- **Efficiency** : 18.06%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does First Solar Inc FS-6455-P-B Compare Against Peer CEC Listings?

Engineering position of First Solar Inc FS-6455-P-B (455.0 W STC) vs. Applied Materials Full Size Tandem Junction across 131 CEC CdTe solar modules.

Ranking #5,417 across 21,677 CEC solar panels (top 26.2%; higher than 73.8% of peers), First Solar Inc FS-6455-P-B operates as a modern high-density residential and light-commercial module sitting 10.0 W above the 445.0 W CdTe median. Higher 222.0 V open-circuit voltage caps 600 V residential strings at 2 panels at 14 F (-10 C). With strong 92.6% PTC-to-STC heat retention (#11,981 of 21,677), 18 panels occupy 488 sq ft and offset roughly $2,050/yr at average US rates (or $3,466/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

## Where Does First Solar Inc FS-6455-P-B Fall Across Listed CEC Models?

Plots First Solar Inc FS-6455-P-B at 455.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

## What Dataset Percentiles Define First Solar Inc FS-6455-P-B?

Benchmarks First Solar Inc FS-6455-P-B on STC wattage, thermal PTC/STC retention, and 18.06 aperture conversion efficiency against CEC peers.

## What Do the Dataset Ranks Show for First Solar Inc FS-6455-P-B?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for First Solar Inc FS-6455-P-B by First Solar Inc.

Rank #5,417 / 21,677

### Top 26.2% STC Output

455.0 W STC (+70.0 W vs all-CEC median) vs 445.0 W CdTe median.

Eff #14,990

### 18.06% Aperture Efficiency

Power density 180.6 W/m2 (1.85 percentage points below 19.91% CEC median). PTC/STC ratio: 92.6% (rank #11,981).

NEC 690.7 Limit

### 2 Panels Max @ -10 C (600 V)

Cold Voc reaches 243.06 V at -10 C (486.1 V string) and 249.07 V at -20 C (2 max).

 8 kW Reference Array

### 18 Panels = 8,190 W STC

Occupies 45.4 m2 (488 sq ft) producing 7,582 W PTC; NEC 690.8 OCPD floor is 4.02 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 222.0 * (1 + (-0.271/100) * (-10 - 25)) = 243.06 V | OCPD = 1.56 * 2.58 = 4.02 A

Inputs from CEC Modules.csv for First Solar Inc FS-6455-P-B: Voc=222.0 V, beta_Voc=-0.271%/C, Isc=2.58 A, STC=455.0 W, Area=2.52 m2.

**Result:** 2 panels max on 600 V (486.1 V); 18 panels for 8 kW (488 sq ft).

## What Are the Published CEC Specifications for First Solar Inc FS-6455-P-B?

Laboratory test ratings recorded for First Solar Inc FS-6455-P-B (CdTe) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for First Solar Inc FS-6455-P-B.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 455.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 421.2 W (92.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 222.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 2.58 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 187.8 V / 2.42 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.271 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 18.06% (2.52 m2) | Array roof footprint density |
| **Cell Count & Technology** | 268 cells (CdTe) | Monofacial backsheet |

## How Many First Solar Inc FS-6455-P-B Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (488 sq ft at 8 kW), and estimated Year-1 electric bill offset for First Solar Inc FS-6455-P-B.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 14 | 6.37 kW | 380 sq ft | $1,594 | $2,696 |
| **8 kW Class** | 18 | 8.19 kW | 488 sq ft | $2,050 | $3,466 |
| **10 kW Class** | 22 | 10.01 kW | 597 sq ft | $2,505 | $4,236 |

## How Many First Solar Inc FS-6455-P-B Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for First Solar Inc FS-6455-P-B (beta_Voc -0.271%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=222.0V and beta_Voc=-0.271%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 249.07 V | 2 panels | 498.1 V | 4 panels |
| **-10 C (14 F)** | 243.06 V | 2 panels | 486.1 V | 4 panels |
| **0 C (32 F)** | 237.04 V | 2 panels | 474.1 V | 4 panels |
| **25 C (77 F STC)** | 222.0 V | 2 panels | 444.0 V | 4 panels |

## Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-6455-P-B?

Closest cross-brand CEC competitors to First Solar Inc FS-6455-P-B matched near 455.0 W STC and 222.0 V Voc, led by Applied Materials Full Size Tandem Junction.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Applied Materials Full Size Tandem Junction**](https://epri-peac.com/solar-equipment/modules/applied-materials/applied-materials-full-size-tandem-junction/) Applied Materials | 458.0 W | +3.0 W | 280.0 V | 8.01% | 91.7% |
| [**Heliene 96M460**](https://epri-peac.com/solar-equipment/modules/heliene/heliene-96m460/) Heliene | 460.0 W | +5.0 W | 61.79 V | 18.25% | 90.4% |
| [**Heliene 96M475**](https://epri-peac.com/solar-equipment/modules/heliene/heliene-96m475/) Heliene | 475.0 W | +20.0 W | 62.39 V | 18.85% | 90.5% |
| [**CSI Solar Co Ltd CS3Y-460P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs3y-460p/) CSI Solar Co Ltd | 460.0 W | +5.0 W | 52.0 V | 20.09% | 93.1% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-6455-P-B?

Evaluate First Solar Inc FS-6455-P-B (455.0 W STC, 222.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-6455-P-B reaches 249.07 V per panel—exceeding 2 panels in series voids 600 V inverter warranties.
- Footprint constraint: 18 panels for an 8 kW build require 488 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (488 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of First Solar Inc FS-6455-P-B carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### First Solar Inc FS-6455-P-B 8 kW Residential Fit

Needs 18 modules (488 sq ft) with a 15 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 2 panels (-10 C) or 2 panels (-20 C), or compare Applied Materials Full Size Tandem Junction.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 421.2 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for First Solar Inc FS-6455-P-B by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

### How many First Solar Inc FS-6455-P-B panels fit on a 600 V winter solar string?

At -10 C (14 F), First Solar Inc FS-6455-P-B cold Voc rises from 222.0 V to 243.06 V (beta_Voc -0.271%/C), capping a 600 V string at 2 panels (486.1 V).

### How much roof area does an 8 kW array of First Solar Inc FS-6455-P-B need?

An 8 kW DC system uses 18 First Solar Inc FS-6455-P-B modules (8,190 W STC / 7,582 W PTC), covering roughly 488 sq ft and saving ~$2,050/yr at 18.54 c/kWh.

### How does First Solar Inc FS-6455-P-B compare against Applied Materials Full Size Tandem Junction?

First Solar Inc FS-6455-P-B outputs 455.0 W STC (222.0 V Voc, rank #5,417 of 21,677), while Applied Materials Full Size Tandem Junction delivers 458.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare First Solar Inc equipment, Applied Materials Full Size Tandem Junction specs, utility payback rates, and NEC string calculators alongside First Solar Inc FS-6455-P-B.

[All First Solar Inc Certified Solar Models](https://epri-peac.com/solar-equipment/brands/first-solar-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From First Solar Inc

- [All First Solar Inc Specs](https://epri-peac.com/solar-equipment/brands/first-solar-inc/)
- [First Solar Inc FS-7550A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7550a-ft1/)
- [First Solar Inc FS-7550A-TR1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7550a-tr1/)
- [First Solar Inc FS-7545A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7545a-ft1/)
- [First Solar Inc FS-7545A-TR1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7545a-tr1/)
- [First Solar Inc FS-7540A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7540a-ft1/)