title: "First Solar Inc FS-6445-P-B-2 Specs (445.0W, 227.42V Voc)"
url: https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-6445-p-b-2/
description: "CEC datasheet for First Solar Inc FS-6445-P-B-2: 445.0W STC, 227.42V Voc, 18-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# First Solar Inc FS-6445-P-B-2 — CEC Solar Module Specifications

Manufacturer: [**First Solar Inc**](https://epri-peac.com/solar-equipment/brands/first-solar-inc/) Registry: **CEC Verified Engineering Specification**

First Solar Inc FS-6445-P-B-2 is a 445.0 W STC (422.6 W PTC) Thin Film solar module ranking #6,028 of 21,677 CEC listings (top 29.6%; higher than 70.4% of peers). It delivers 17.66% efficiency, 227.42 V Voc at 25 C, and 245.41 V cold Voc at -10 C (2 panels max per 600 V string).

- **STC Wattage** : 445.0 W

- **PTC Wattage** : 422.6 W

- **Voc @ 25C** : 227.42 V

- **Efficiency** : 17.66%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does First Solar Inc FS-6445-P-B-2 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for First Solar Inc FS-6445-P-B-2 (Thin Film) residential solar systems.

First Solar Inc FS-6445-P-B-2 delivers 176.6 W/m2 (2.25 percentage points below 19.91% CEC median) and strong 95.0% PTC-to-STC heat retention (#1,106 of 21,677), placing it as a modern high-density residential and light-commercial module well-proportioned for residential pitched roofs needing 18 panels (488 sq ft) for an 8 kW array. At -4 F (-20 C), string voltage climbs to 250.55 V per unit, capping 600 V circuits at 2 panels. Compare specs directly with Applied Materials Full Size Single Junction Version 10 (414.0 W).

## Where Does First Solar Inc FS-6445-P-B-2 Fall Across Listed CEC Models?

Comparison of First Solar Inc FS-6445-P-B-2 (445.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

## What Dataset Percentiles Define First Solar Inc FS-6445-P-B-2?

Relative ranking of First Solar Inc FS-6445-P-B-2 across nameplate watts, 95.0% PTC thermal ratio, and module aperture efficiency.

## What Do the Dataset Ranks Show for First Solar Inc FS-6445-P-B-2?

Summary of First Solar Inc FS-6445-P-B-2 output rank, 8 kW array size (18 panels), efficiency rating, and 600 V string limit.

Rank #6,028 / 21,677

### Top 29.6% STC Output

445.0 W STC (+60.0 W vs all-CEC median) vs 117.5 W Thin Film median.

Eff #15,561

### 17.66% Aperture Efficiency

Power density 176.6 W/m2 (2.25 percentage points below 19.91% CEC median). PTC/STC ratio: 95.0% (rank #1,106).

NEC 690.7 Limit

### 2 Panels Max @ -10 C (600 V)

Cold Voc reaches 245.41 V at -10 C (490.8 V string) and 250.55 V at -20 C (2 max).

 8 kW Reference Array

### 18 Panels = 8,010 W STC

Occupies 45.4 m2 (488 sq ft) producing 7,607 W PTC; NEC 690.8 OCPD floor is 4.2 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 227.42 * (1 + (-0.226/100) * (-10 - 25)) = 245.41 V | OCPD = 1.56 * 2.69 = 4.2 A

Inputs from CEC Modules.csv for First Solar Inc FS-6445-P-B-2: Voc=227.42 V, beta_Voc=-0.226%/C, Isc=2.69 A, STC=445.0 W, Area=2.52 m2.

**Result:** 2 panels max on 600 V (490.8 V); 18 panels for 8 kW (488 sq ft).

## What Are the Published CEC Specifications for First Solar Inc FS-6445-P-B-2?

Complete CEC test sheet for First Solar Inc FS-6445-P-B-2 including Isc (2.69 A), Voc (227.42 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for First Solar Inc FS-6445-P-B-2.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 445.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 422.6 W (95.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 227.42 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 2.69 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 179.52 V / 2.48 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.226 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 17.66% (2.52 m2) | Array roof footprint density |
| **Cell Count & Technology** | 268 cells (Thin Film) | Monofacial backsheet |

## How Many First Solar Inc FS-6445-P-B-2 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using First Solar Inc FS-6445-P-B-2.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 14 | 6.23 kW | 380 sq ft | $1,559 | $2,637 |
| **8 kW Class** | 18 | 8.01 kW | 488 sq ft | $2,005 | $3,390 |
| **10 kW Class** | 23 | 10.23 kW | 624 sq ft | $2,560 | $4,330 |

## How Many First Solar Inc FS-6445-P-B-2 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for First Solar Inc FS-6445-P-B-2 (227.42 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=227.42V and beta_Voc=-0.226%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 250.55 V | 2 panels | 501.1 V | 3 panels |
| **-10 C (14 F)** | 245.41 V | 2 panels | 490.8 V | 4 panels |
| **0 C (32 F)** | 240.27 V | 2 panels | 480.5 V | 4 panels |
| **25 C (77 F STC)** | 227.42 V | 2 panels | 454.8 V | 4 panels |

## Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-6445-P-B-2?

Four comparable CEC modules such as Applied Materials Full Size Single Junction Version 10 (414.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Applied Materials Full Size Single Junction Version 10**](https://epri-peac.com/solar-equipment/modules/applied-materials/applied-materials-full-size-single-junction-version-10/) Applied Materials | 414.0 W | -31.0 W | 194.2 V | 7.24% | 92.9% |
| [**CSI Solar Co Ltd CS3Y-445P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs3y-445p/) CSI Solar Co Ltd | 445.0 W | Tie (0 W) | 51.4 V | 19.43% | 93.0% |
| [**Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-440W**](https://epri-peac.com/solar-equipment/modules/amerisolar-worldwide-energy-and-manufacturing-usa-co-ltd/amerisolar-worldwide-energy-and-manufacturing-usa-co-ltd-as-6m144-hc-440w/) Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd | 440.0 W | -5.0 W | 49.6 V | 20.75% | 92.4% |
| [**Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-BHC-440W**](https://epri-peac.com/solar-equipment/modules/amerisolar-worldwide-energy-and-manufacturing-usa-co-ltd/amerisolar-worldwide-energy-and-manufacturing-usa-co-ltd-as-6m144-bhc-440w/) Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd | 440.0 W | -5.0 W | 49.3 V | 20.56% | 92.6% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-6445-P-B-2?

Evaluate First Solar Inc FS-6445-P-B-2 (445.0 W STC, 227.42 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-6445-P-B-2 reaches 250.55 V per panel—exceeding 2 panels in series voids 600 V inverter warranties.
- Footprint constraint: 18 panels for an 8 kW build require 488 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (488 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of First Solar Inc FS-6445-P-B-2 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### First Solar Inc FS-6445-P-B-2 8 kW Residential Fit

Needs 18 modules (488 sq ft) with a 15 A string OCPD, offsetting ~$2,005/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 2 panels (-10 C) or 2 panels (-20 C), or compare Applied Materials Full Size Single Junction Version 10.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 422.6 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for First Solar Inc FS-6445-P-B-2 by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

### How many First Solar Inc FS-6445-P-B-2 panels fit on a 600 V winter solar string?

At -10 C (14 F), First Solar Inc FS-6445-P-B-2 cold Voc rises from 227.42 V to 245.41 V (beta_Voc -0.226%/C), capping a 600 V string at 2 panels (490.8 V).

### How much roof area does an 8 kW array of First Solar Inc FS-6445-P-B-2 need?

An 8 kW DC system uses 18 First Solar Inc FS-6445-P-B-2 modules (8,010 W STC / 7,607 W PTC), covering roughly 488 sq ft and saving ~$2,005/yr at 18.54 c/kWh.

### How does First Solar Inc FS-6445-P-B-2 compare against Applied Materials Full Size Single Junction Version 10?

First Solar Inc FS-6445-P-B-2 outputs 445.0 W STC (227.42 V Voc, rank #6,028 of 21,677), while Applied Materials Full Size Single Junction Version 10 delivers 414.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare First Solar Inc equipment, Applied Materials Full Size Single Junction Version 10 specs, utility payback rates, and NEC string calculators alongside First Solar Inc FS-6445-P-B-2.

[All First Solar Inc Certified Solar Models](https://epri-peac.com/solar-equipment/brands/first-solar-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From First Solar Inc

- [All First Solar Inc Specs](https://epri-peac.com/solar-equipment/brands/first-solar-inc/)
- [First Solar Inc FS-7550A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7550a-ft1/)
- [First Solar Inc FS-7550A-TR1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7550a-tr1/)
- [First Solar Inc FS-7545A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7545a-ft1/)
- [First Solar Inc FS-7545A-TR1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7545a-tr1/)
- [First Solar Inc FS-7540A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7540a-ft1/)