title: "First Solar Inc FS-6435 Specs (435.0W, 219.6V Voc)"
url: https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-6435/
description: "CEC datasheet for First Solar Inc FS-6435: 435.0W STC, 219.6V Voc, 19-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# First Solar Inc FS-6435 — CEC Solar Module Specifications

Manufacturer: [**First Solar Inc**](https://epri-peac.com/solar-equipment/brands/first-solar-inc/) Registry: **CEC Verified Engineering Specification**

First Solar Inc FS-6435 is a 435.0 W STC (409.4 W PTC) CdTe solar module ranking #6,850 of 21,677 CEC listings (top 33.5%; higher than 66.5% of peers). It delivers 17.58% efficiency, 219.6 V Voc at 25 C, and 240.66 V cold Voc at -10 C (2 panels max per 600 V string).

- **STC Wattage** : 435.0 W

- **PTC Wattage** : 409.4 W

- **Voc @ 25C** : 219.6 V

- **Efficiency** : 17.58%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does First Solar Inc FS-6435 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for First Solar Inc FS-6435 (CdTe) residential solar systems.

Homeowners evaluating First Solar Inc FS-6435 need 14 panels for 6 kW or 19 panels (506 sq ft) for an 8 kW array—well-proportioned for residential pitched roofs needing 19 panels (506 sq ft) for an 8 kW array. Under NEC 690.7(A), beta_Voc (-0.274%/C) pushes open-circuit voltage to 240.66 V at 14 F and 246.68 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

## Where Does First Solar Inc FS-6435 Fall Across Listed CEC Models?

Comparison of First Solar Inc FS-6435 (435.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

## What Dataset Percentiles Define First Solar Inc FS-6435?

Relative ranking of First Solar Inc FS-6435 across nameplate watts, 94.1% PTC thermal ratio, and module aperture efficiency.

## What Do the Dataset Ranks Show for First Solar Inc FS-6435?

Summary of First Solar Inc FS-6435 output rank, 8 kW array size (19 panels), efficiency rating, and 600 V string limit.

Rank #6,850 / 21,677

### Top 33.5% STC Output

435.0 W STC (+50.0 W vs all-CEC median) vs 445.0 W CdTe median.

Eff #15,678

### 17.58% Aperture Efficiency

Power density 175.8 W/m2 (2.33 percentage points below 19.91% CEC median). PTC/STC ratio: 94.1% (rank #4,203).

NEC 690.7 Limit

### 2 Panels Max @ -10 C (600 V)

Cold Voc reaches 240.66 V at -10 C (481.3 V string) and 246.68 V at -20 C (2 max).

 8 kW Reference Array

### 19 Panels = 8,265 W STC

Occupies 47.0 m2 (506 sq ft) producing 7,779 W PTC; NEC 690.8 OCPD floor is 3.98 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 219.6 * (1 + (-0.274/100) * (-10 - 25)) = 240.66 V | OCPD = 1.56 * 2.55 = 3.98 A

Inputs from CEC Modules.csv for First Solar Inc FS-6435: Voc=219.6 V, beta_Voc=-0.274%/C, Isc=2.55 A, STC=435.0 W, Area=2.475 m2.

**Result:** 2 panels max on 600 V (481.3 V); 19 panels for 8 kW (506 sq ft).

## What Are the Published CEC Specifications for First Solar Inc FS-6435?

Complete CEC test sheet for First Solar Inc FS-6435 including Isc (2.55 A), Voc (219.6 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for First Solar Inc FS-6435.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 435.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 409.4 W (94.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 219.6 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 2.55 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 183.6 V / 2.37 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.274 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 17.58% (2.475 m2) | Array roof footprint density |
| **Cell Count & Technology** | 264 cells (CdTe) | Monofacial backsheet |

## How Many First Solar Inc FS-6435 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using First Solar Inc FS-6435.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 14 | 6.09 kW | 373 sq ft | $1,524 | $2,577 |
| **8 kW Class** | 19 | 8.27 kW | 506 sq ft | $2,070 | $3,500 |
| **10 kW Class** | 23 | 10.01 kW | 613 sq ft | $2,505 | $4,236 |

## How Many First Solar Inc FS-6435 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for First Solar Inc FS-6435 (219.6 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=219.6V and beta_Voc=-0.274%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 246.68 V | 2 panels | 493.4 V | 4 panels |
| **-10 C (14 F)** | 240.66 V | 2 panels | 481.3 V | 4 panels |
| **0 C (32 F)** | 234.64 V | 2 panels | 469.3 V | 4 panels |
| **25 C (77 F STC)** | 219.6 V | 2 panels | 439.2 V | 4 panels |

## Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-6435?

Four comparable CEC modules such as Applied Materials Full Size Single Junction Version 10 (414.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Applied Materials Full Size Single Junction Version 10**](https://epri-peac.com/solar-equipment/modules/applied-materials/applied-materials-full-size-single-junction-version-10/) Applied Materials | 414.0 W | -21.0 W | 194.2 V | 7.24% | 92.9% |
| [**Aptos Solar Technology LLC DNA-144-MF26-435W {Blk}**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-144-mf26-435w-blk/) Aptos Solar Technology LLC | 435.0 W | Tie (0 W) | 49.7 V | 20.71% | 91.8% |
| [**Aptos Solar Technology LLC DNA-144-MF26-435W {Wht}**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-144-mf26-435w-wht/) Aptos Solar Technology LLC | 435.0 W | Tie (0 W) | 49.7 V | 20.71% | 92.8% |
| [**CertainTeed CT435HC11-06**](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-ct435hc11-06/) CertainTeed | 435.0 W | Tie (0 W) | 49.7 V | 20.71% | 91.8% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-6435?

Evaluate First Solar Inc FS-6435 (435.0 W STC, 219.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-6435 reaches 246.68 V per panel—exceeding 2 panels in series voids 600 V inverter warranties.
- Footprint constraint: 19 panels for an 8 kW build require 506 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (506 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of First Solar Inc FS-6435 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### First Solar Inc FS-6435 8 kW Residential Fit

Needs 19 modules (506 sq ft) with a 15 A string OCPD, offsetting ~$2,070/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 2 panels (-10 C) or 2 panels (-20 C), or compare Applied Materials Full Size Single Junction Version 10.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 409.4 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for First Solar Inc FS-6435 by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is First Solar Inc FS-6435 PTC wattage (409.4 W) lower than STC (435.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 409.4 W PTC (94.1% retention) across First Solar Inc FS-6435's 2.475 m2 aperture.

### Who should skip First Solar Inc FS-6435 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 19 First Solar Inc FS-6435 panels (506 sq ft) leave unusable roof gaps vs. Applied Materials Full Size Single Junction Version 10.

### What is the 1,000 V commercial string limit for First Solar Inc FS-6435?

On 1,000 V commercial inverters at -10 C (240.66 V cold Voc), First Solar Inc FS-6435 fits up to 4 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting First Solar Inc FS-6435.

## Related Pages

Compare First Solar Inc equipment, Applied Materials Full Size Single Junction Version 10 specs, utility payback rates, and NEC string calculators alongside First Solar Inc FS-6435.

[All First Solar Inc Certified Solar Models](https://epri-peac.com/solar-equipment/brands/first-solar-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From First Solar Inc

- [All First Solar Inc Specs](https://epri-peac.com/solar-equipment/brands/first-solar-inc/)
- [First Solar Inc FS-7550A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7550a-ft1/)
- [First Solar Inc FS-7550A-TR1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7550a-tr1/)
- [First Solar Inc FS-7545A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7545a-ft1/)
- [First Solar Inc FS-7545A-TR1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7545a-tr1/)
- [First Solar Inc FS-7540A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7540a-ft1/)