title: "First Solar Inc FS-6425A-P-B-2 Specs (425.0W, 224.83V Voc)"
url: https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-6425a-p-b-2/
description: "CEC datasheet for First Solar Inc FS-6425A-P-B-2: 425.0W STC, 224.83V Voc, 19-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# First Solar Inc FS-6425A-P-B-2 — CEC Solar Module Specifications

Manufacturer: [**First Solar Inc**](https://epri-peac.com/solar-equipment/brands/first-solar-inc/) Registry: **CEC Verified Engineering Specification**

First Solar Inc FS-6425A-P-B-2 is a 425.0 W STC (403.2 W PTC) Thin Film solar module ranking #7,622 of 21,677 CEC listings (top 36.5%; higher than 63.5% of peers). It delivers 16.87% efficiency, 224.83 V Voc at 25 C, and 242.61 V cold Voc at -10 C (2 panels max per 600 V string).

- **STC Wattage** : 425.0 W

- **PTC Wattage** : 403.2 W

- **Voc @ 25C** : 224.83 V

- **Efficiency** : 16.87%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does First Solar Inc FS-6425A-P-B-2 Compare Against Peer CEC Listings?

How First Solar Inc First Solar Inc FS-6425A-P-B-2 handles rooftop heat (403.2 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, First Solar Inc FS-6425A-P-B-2 exhibits 2.66 A short-circuit current, requiring a 4.15 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #7,622 of 21,677 (307.5 W above the 117.5 W Thin Film median), this modern high-density residential and light-commercial module covers 47.9 m2 for an 8 kW system (24 panels for 10 kW). Higher 224.83 V open-circuit voltage caps 600 V residential strings at 2 panels at 14 F (-10 C).

## Where Does First Solar Inc FS-6425A-P-B-2 Fall Across Listed CEC Models?

Where First Solar Inc FS-6425A-P-B-2 (425.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define First Solar Inc FS-6425A-P-B-2?

Percentile placement of First Solar Inc FS-6425A-P-B-2 across power density (168.7 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for First Solar Inc FS-6425A-P-B-2?

Four critical engineering numbers homeowners and solar installers check first when reviewing First Solar Inc FS-6425A-P-B-2 specifications. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Rank #7,622 / 21,677

### Top 36.5% STC Output

425.0 W STC (+40.0 W vs all-CEC median) vs 117.5 W Thin Film median.

Eff #16,673

### 16.87% Aperture Efficiency

Power density 168.7 W/m2 (3.04 percentage points below 19.91% CEC median). PTC/STC ratio: 94.9% (rank #1,466).

NEC 690.7 Limit

### 2 Panels Max @ -10 C (600 V)

Cold Voc reaches 242.61 V at -10 C (485.2 V string) and 247.7 V at -20 C (2 max).

 8 kW Reference Array

### 19 Panels = 8,075 W STC

Occupies 47.9 m2 (515 sq ft) producing 7,661 W PTC; NEC 690.8 OCPD floor is 4.15 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 224.83 * (1 + (-0.226/100) * (-10 - 25)) = 242.61 V | OCPD = 1.56 * 2.66 = 4.15 A

Inputs from CEC Modules.csv for First Solar Inc FS-6425A-P-B-2: Voc=224.83 V, beta_Voc=-0.226%/C, Isc=2.66 A, STC=425.0 W, Area=2.52 m2.

**Result:** 2 panels max on 600 V (485.2 V); 19 panels for 8 kW (515 sq ft).

## What Are the Published CEC Specifications for First Solar Inc FS-6425A-P-B-2?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for First Solar Inc FS-6425A-P-B-2.

Official California Energy Commission (NREL SAM) test parameters for First Solar Inc FS-6425A-P-B-2.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 425.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 403.2 W (94.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 224.83 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 2.66 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 175.44 V / 2.42 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.226 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 16.87% (2.52 m2) | Array roof footprint density |
| **Cell Count & Technology** | 268 cells (Thin Film) | Monofacial backsheet |

## How Many First Solar Inc FS-6425A-P-B-2 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using First Solar Inc FS-6425A-P-B-2 (425.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 15 | 6.38 kW | 407 sq ft | $1,597 | $2,700 |
| **8 kW Class** | 19 | 8.07 kW | 515 sq ft | $2,020 | $3,415 |
| **10 kW Class** | 24 | 10.2 kW | 651 sq ft | $2,553 | $4,317 |

## How Many First Solar Inc FS-6425A-P-B-2 Modules Fit in a Cold-Weather String?

Maximum series module counts for First Solar Inc FS-6425A-P-B-2 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=224.83V and beta_Voc=-0.226%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 247.7 V | 2 panels | 495.4 V | 4 panels |
| **-10 C (14 F)** | 242.61 V | 2 panels | 485.2 V | 4 panels |
| **0 C (32 F)** | 237.53 V | 2 panels | 475.1 V | 4 panels |
| **25 C (77 F STC)** | 224.83 V | 2 panels | 449.7 V | 4 panels |

## Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-6425A-P-B-2?

Alternative CEC solar modules from competing brands near First Solar Inc FS-6425A-P-B-2 (425.0 W), including Applied Materials Full Size Single Junction Version 10.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Applied Materials Full Size Single Junction Version 10**](https://epri-peac.com/solar-equipment/modules/applied-materials/applied-materials-full-size-single-junction-version-10/) Applied Materials | 414.0 W | -11.0 W | 194.2 V | 7.24% | 92.9% |
| [**CSI Solar Co Ltd CS1Y-410MS**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs1y-410ms/) CSI Solar Co Ltd | 410.0 W | -15.0 W | 52.7 V | 21.03% | 94.1% |
| [**DualSun SAS DualSun 420M-144-01**](https://epri-peac.com/solar-equipment/modules/dualsun-sas/dualsun-sas-dualsun-420m-144-01/) DualSun SAS | 420.0 W | -5.0 W | 48.8 V | 19.44% | 93.8% |
| [**Aptos Solar Technology LLC DNA-144-MF26-435W {Blk}**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-144-mf26-435w-blk/) Aptos Solar Technology LLC | 435.0 W | +10.0 W | 49.7 V | 20.71% | 91.8% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-6425A-P-B-2?

Evaluate First Solar Inc FS-6425A-P-B-2 (425.0 W STC, 224.83 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-6425A-P-B-2 reaches 247.7 V per panel—exceeding 2 panels in series voids 600 V inverter warranties.
- Footprint constraint: 19 panels for an 8 kW build require 515 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (515 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of First Solar Inc FS-6425A-P-B-2 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### First Solar Inc FS-6425A-P-B-2 8 kW Residential Fit

Needs 19 modules (515 sq ft) with a 15 A string OCPD, offsetting ~$2,020/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 2 panels (-10 C) or 2 panels (-20 C), or compare Applied Materials Full Size Single Junction Version 10.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 403.2 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for First Solar Inc FS-6425A-P-B-2 by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is First Solar Inc FS-6425A-P-B-2 PTC wattage (403.2 W) lower than STC (425.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 403.2 W PTC (94.9% retention) across First Solar Inc FS-6425A-P-B-2's 2.52 m2 aperture.

### Who should skip First Solar Inc FS-6425A-P-B-2 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 19 First Solar Inc FS-6425A-P-B-2 panels (515 sq ft) leave unusable roof gaps vs. Applied Materials Full Size Single Junction Version 10.

### What is the 1,000 V commercial string limit for First Solar Inc FS-6425A-P-B-2?

On 1,000 V commercial inverters at -10 C (242.61 V cold Voc), First Solar Inc FS-6425A-P-B-2 fits up to 4 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting First Solar Inc FS-6425A-P-B-2.

## Related Pages

Compare First Solar Inc equipment, Applied Materials Full Size Single Junction Version 10 specs, utility payback rates, and NEC string calculators alongside First Solar Inc FS-6425A-P-B-2.

[All First Solar Inc Certified Solar Models](https://epri-peac.com/solar-equipment/brands/first-solar-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From First Solar Inc

- [All First Solar Inc Specs](https://epri-peac.com/solar-equipment/brands/first-solar-inc/)
- [First Solar Inc FS-7550A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7550a-ft1/)
- [First Solar Inc FS-7550A-TR1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7550a-tr1/)
- [First Solar Inc FS-7545A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7545a-ft1/)
- [First Solar Inc FS-7545A-TR1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7545a-tr1/)
- [First Solar Inc FS-7540A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7540a-ft1/)