title: "First Solar Inc FS-6410 Specs (410.0W, 217.4V Voc)"
url: https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-6410/
description: "CEC datasheet for First Solar Inc FS-6410: 410.0W STC, 217.4V Voc, 20-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# First Solar Inc FS-6410 — CEC Solar Module Specifications

Manufacturer: [**First Solar Inc**](https://epri-peac.com/solar-equipment/brands/first-solar-inc/) Registry: **CEC Verified Engineering Specification**

First Solar Inc FS-6410 is a 410.0 W STC (382.2 W PTC) CdTe solar module ranking #8,539 of 21,677 CEC listings (top 41.3%; higher than 58.7% of peers). It delivers 16.53% efficiency, 217.4 V Voc at 25 C, and 238.63 V cold Voc at -10 C (2 panels max per 600 V string).

- **STC Wattage** : 410.0 W

- **PTC Wattage** : 382.2 W

- **Voc @ 25C** : 217.4 V

- **Efficiency** : 16.53%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does First Solar Inc FS-6410 Compare Against Peer CEC Listings?

Solar engineering breakdown for First Solar Inc FS-6410: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 410.0 W STC and 382.2 W PTC, First Solar Inc FS-6410 sits +25.0 W vs all-CEC median (top 41.3%; higher than 58.7% of peers) among 21,677 listed modules. Power density reaches 165.3 W/m2 (3.38 percentage points below 19.91% CEC median). Higher 217.4 V open-circuit voltage caps 600 V residential strings at 2 panels at 14 F (-10 C), whereas 1,000 V commercial inverters handle up to 4 panels in series. Alternative peer Applied Materials Full Size Single Junction Version 10 rates 414.0 W.

## Where Does First Solar Inc FS-6410 Fall Across Listed CEC Models?

Distribution marker showing First Solar Inc FS-6410 (410.0 W) relative to the 385.0 W all-CEC solar panel median.

## What Dataset Percentiles Define First Solar Inc FS-6410?

Dataset percentiles tracking First Solar Inc FS-6410 power output, thermal retention ratio, and aperture efficiency against 21,677 models.

## What Do the Dataset Ranks Show for First Solar Inc FS-6410?

Benchmark highlights for First Solar Inc FS-6410 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #8,539 / 21,677

### Top 41.3% STC Output

410.0 W STC (+25.0 W vs all-CEC median) vs 445.0 W CdTe median.

Eff #17,241

### 16.53% Aperture Efficiency

Power density 165.3 W/m2 (3.38 percentage points below 19.91% CEC median). PTC/STC ratio: 93.2% (rank #8,924).

NEC 690.7 Limit

### 2 Panels Max @ -10 C (600 V)

Cold Voc reaches 238.63 V at -10 C (477.3 V string) and 244.69 V at -20 C (2 max).

 8 kW Reference Array

### 20 Panels = 8,200 W STC

Occupies 49.6 m2 (534 sq ft) producing 7,644 W PTC; NEC 690.8 OCPD floor is 3.93 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 217.4 * (1 + (-0.279/100) * (-10 - 25)) = 238.63 V | OCPD = 1.56 * 2.52 = 3.93 A

Inputs from CEC Modules.csv for First Solar Inc FS-6410: Voc=217.4 V, beta_Voc=-0.279%/C, Isc=2.52 A, STC=410.0 W, Area=2.48 m2.

**Result:** 2 panels max on 600 V (477.3 V); 20 panels for 8 kW (534 sq ft).

## What Are the Published CEC Specifications for First Solar Inc FS-6410?

Official CEC datasheet figures for First Solar Inc FS-6410 (CdTe) used in utility interconnection and permit reviews. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Official California Energy Commission (NREL SAM) test parameters for First Solar Inc FS-6410.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 410.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 382.2 W (93.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 217.4 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 2.52 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 178.3 V / 2.3 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.279 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 16.53% (2.48 m2) | Array roof footprint density |
| **Cell Count & Technology** | 264 cells (CdTe) | Monofacial backsheet |

## How Many First Solar Inc FS-6410 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many First Solar Inc FS-6410 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 15 | 6.15 kW | 400 sq ft | $1,539 | $2,603 |
| **8 kW Class** | 20 | 8.2 kW | 534 sq ft | $2,052 | $3,470 |
| **10 kW Class** | 25 | 10.25 kW | 667 sq ft | $2,565 | $4,338 |

## How Many First Solar Inc FS-6410 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on First Solar Inc FS-6410 (238.63 V at 14 F).

Computed from Voc=217.4V and beta_Voc=-0.279%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 244.69 V | 2 panels | 489.4 V | 4 panels |
| **-10 C (14 F)** | 238.63 V | 2 panels | 477.3 V | 4 panels |
| **0 C (32 F)** | 232.56 V | 2 panels | 465.1 V | 4 panels |
| **25 C (77 F STC)** | 217.4 V | 2 panels | 434.8 V | 4 panels |

## Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-6410?

Competing CEC solar panels closest to First Solar Inc FS-6410 in nameplate wattage and Voc, starting with Applied Materials Full Size Single Junction Version 10.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Applied Materials Full Size Single Junction Version 10**](https://epri-peac.com/solar-equipment/modules/applied-materials/applied-materials-full-size-single-junction-version-10/) Applied Materials | 414.0 W | +4.0 W | 194.2 V | 7.24% | 92.9% |
| [**CSI Solar Co Ltd CS1Y-410MS**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs1y-410ms/) CSI Solar Co Ltd | 410.0 W | Tie (0 W) | 52.7 V | 21.03% | 94.1% |
| [**Auxin Solar AXNG1M410B**](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axng1m410b/) Auxin Solar | 410.0 W | Tie (0 W) | 49.47 V | 20.92% | 93.4% |
| [**Auxin Solar AXNG1M410W**](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axng1m410w/) Auxin Solar | 410.0 W | Tie (0 W) | 49.47 V | 20.92% | 93.3% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-6410?

Evaluate First Solar Inc FS-6410 (410.0 W STC, 217.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-6410 reaches 244.69 V per panel—exceeding 2 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 534 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (534 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of First Solar Inc FS-6410 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### First Solar Inc FS-6410 8 kW Residential Fit

Needs 20 modules (534 sq ft) with a 15 A string OCPD, offsetting ~$2,052/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 2 panels (-10 C) or 2 panels (-20 C), or compare Applied Materials Full Size Single Junction Version 10.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 382.2 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for First Solar Inc FS-6410 by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

### How many First Solar Inc FS-6410 panels fit on a 600 V winter solar string?

At -10 C (14 F), First Solar Inc FS-6410 cold Voc rises from 217.4 V to 238.63 V (beta_Voc -0.279%/C), capping a 600 V string at 2 panels (477.3 V).

### How much roof area does an 8 kW array of First Solar Inc FS-6410 need?

An 8 kW DC system uses 20 First Solar Inc FS-6410 modules (8,200 W STC / 7,644 W PTC), covering roughly 534 sq ft and saving ~$2,052/yr at 18.54 c/kWh.

### How does First Solar Inc FS-6410 compare against Applied Materials Full Size Single Junction Version 10?

First Solar Inc FS-6410 outputs 410.0 W STC (217.4 V Voc, rank #8,539 of 21,677), while Applied Materials Full Size Single Junction Version 10 delivers 414.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare First Solar Inc equipment, Applied Materials Full Size Single Junction Version 10 specs, utility payback rates, and NEC string calculators alongside First Solar Inc FS-6410.

[All First Solar Inc Certified Solar Models](https://epri-peac.com/solar-equipment/brands/first-solar-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From First Solar Inc

- [All First Solar Inc Specs](https://epri-peac.com/solar-equipment/brands/first-solar-inc/)
- [First Solar Inc FS-7550A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7550a-ft1/)
- [First Solar Inc FS-7550A-TR1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7550a-tr1/)
- [First Solar Inc FS-7545A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7545a-ft1/)
- [First Solar Inc FS-7545A-TR1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7545a-tr1/)
- [First Solar Inc FS-7540A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7540a-ft1/)