---
title: "First Solar Inc FS-6395 Specs (395.0W, 215.4V Voc)"
url: https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-6395/
description: "CEC datasheet for First Solar Inc FS-6395: 395.0W STC, 215.4V Voc, 21-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# First Solar Inc FS-6395 — CEC Solar Module Specifications

Manufacturer: [**First Solar Inc**](https://epri-peac.com/solar-equipment/brands/first-solar-inc/) Registry: **CEC Verified Engineering Specification**

First Solar Inc FS-6395 is a 395.0 W STC (368.0 W PTC) CdTe solar module ranking #9,869 of 21,677 CEC listings (top 47.6%; higher than 52.4% of peers). It delivers 15.93% efficiency, 215.4 V Voc at 25 C, and 236.43 V cold Voc at -10 C (2 panels max per 600 V string).

- **STC Wattage** : 395.0 W

- **PTC Wattage** : 368.0 W

- **Voc @ 25C** : 215.4 V

- **Efficiency** : 15.93%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does First Solar Inc FS-6395 Compare Against Peer CEC Listings?

Solar engineering breakdown for First Solar Inc FS-6395: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 131 CdTe listings from First Solar Inc and peers, First Solar Inc FS-6395 stands 50.0 W below the 445.0 W CdTe median and strong 93.2% PTC-to-STC heat retention (#8,924 of 21,677). Sizing 6 kW (16 panels) to 10 kW (26 panels) yields $1,582-$2,570/yr in baseline US bill offset. Higher 215.4 V open-circuit voltage caps 600 V residential strings at 2 panels at 14 F (-10 C).

## Where Does First Solar Inc FS-6395 Fall Across Listed CEC Models?

Distribution marker showing First Solar Inc FS-6395 (395.0 W) relative to the 385.0 W all-CEC solar panel median.

## What Dataset Percentiles Define First Solar Inc FS-6395?

Dataset percentiles tracking First Solar Inc FS-6395 power output, thermal retention ratio, and aperture efficiency against 21,677 models.

## What Do the Dataset Ranks Show for First Solar Inc FS-6395?

Benchmark highlights for First Solar Inc FS-6395 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #9,869 / 21,677

### Top 47.6% STC Output

395.0 W STC (+10.0 W vs all-CEC median) vs 445.0 W CdTe median.

Eff #18,285

### 15.93% Aperture Efficiency

Power density 159.3 W/m2 (3.98 percentage points below 19.91% CEC median). PTC/STC ratio: 93.2% (rank #8,924).

NEC 690.7 Limit

### 2 Panels Max @ -10 C (600 V)

Cold Voc reaches 236.43 V at -10 C (472.9 V string) and 242.44 V at -20 C (2 max).

 8 kW Reference Array

### 21 Panels = 8,295 W STC

Occupies 52.1 m2 (561 sq ft) producing 7,728 W PTC; NEC 690.8 OCPD floor is 3.9 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 215.4 * (1 + (-0.279/100) * (-10 - 25)) = 236.43 V | OCPD = 1.56 * 2.5 = 3.9 A

Inputs from CEC Modules.csv for First Solar Inc FS-6395: Voc=215.4 V, beta_Voc=-0.279%/C, Isc=2.5 A, STC=395.0 W, Area=2.48 m2.

**Result:** 2 panels max on 600 V (472.9 V); 21 panels for 8 kW (561 sq ft).

## What Are the Published CEC Specifications for First Solar Inc FS-6395?

Official CEC datasheet figures for First Solar Inc FS-6395 (CdTe) used in utility interconnection and permit reviews. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Official California Energy Commission (NREL SAM) test parameters for First Solar Inc FS-6395.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 395.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 368.0 W (93.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 215.4 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 2.5 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 175.0 V / 2.26 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.279 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 15.93% (2.48 m2) | Array roof footprint density |
| **Cell Count & Technology** | 264 cells (CdTe) | Monofacial backsheet |

## How Many First Solar Inc FS-6395 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many First Solar Inc FS-6395 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 16 | 6.32 kW | 427 sq ft | $1,582 | $2,675 |
| **8 kW Class** | 21 | 8.29 kW | 561 sq ft | $2,075 | $3,509 |
| **10 kW Class** | 26 | 10.27 kW | 694 sq ft | $2,570 | $4,347 |

## How Many First Solar Inc FS-6395 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on First Solar Inc FS-6395 (236.43 V at 14 F).

Computed from Voc=215.4V and beta_Voc=-0.279%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 242.44 V | 2 panels | 484.9 V | 4 panels |
| **-10 C (14 F)** | 236.43 V | 2 panels | 472.9 V | 4 panels |
| **0 C (32 F)** | 230.42 V | 2 panels | 460.8 V | 4 panels |
| **25 C (77 F STC)** | 215.4 V | 2 panels | 430.8 V | 4 panels |

## Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-6395?

Competing CEC solar panels closest to First Solar Inc FS-6395 in nameplate wattage and Voc, starting with CSI Solar Co Ltd CS1Y-390MS.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**CSI Solar Co Ltd CS1Y-390MS**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs1y-390ms/) CSI Solar Co Ltd | 390.0 W | -5.0 W | 51.9 V | 20.0% | 94.0% |
| [**BYD Company Limited BYD415MIK-36**](https://epri-peac.com/solar-equipment/modules/byd-company-limited/byd-company-limited-byd415mik-36/) BYD Company Limited | 395.0 W | Tie (0 W) | 50.06 V | 19.65% | 93.9% |
| [**ELITE Solar ET-M672BH395GL**](https://epri-peac.com/solar-equipment/modules/elite-solar/elite-solar-et-m672bh395gl/) ELITE Solar | 395.0 W | Tie (0 W) | 49.6 V | 19.36% | 93.2% |
| [**ELITE Solar ET-M672BH395WW**](https://epri-peac.com/solar-equipment/modules/elite-solar/elite-solar-et-m672bh395ww/) ELITE Solar | 395.0 W | Tie (0 W) | 49.5 V | 19.85% | 93.3% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-6395?

Evaluate First Solar Inc FS-6395 (395.0 W STC, 215.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-6395 reaches 242.44 V per panel—exceeding 2 panels in series voids 600 V inverter warranties.
- Footprint constraint: 21 panels for an 8 kW build require 561 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (561 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of First Solar Inc FS-6395 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### First Solar Inc FS-6395 8 kW Residential Fit

Needs 21 modules (561 sq ft) with a 15 A string OCPD, offsetting ~$2,075/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 2 panels (-10 C) or 2 panels (-20 C), or compare CSI Solar Co Ltd CS1Y-390MS.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 368.0 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for First Solar Inc FS-6395 by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for First Solar Inc FS-6395?

Multiplying First Solar Inc FS-6395's 2.5 A short-circuit current by 1.56 equals 3.9 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

### Can First Solar Inc FS-6395 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 236.43 V cold Voc at 14 F and handles 2.5 A Isc; string inverters cap First Solar Inc FS-6395 at 2 panels on 600 V.

### Is First Solar Inc FS-6395 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of First Solar Inc FS-6395 rely on utility bill offset (~$2,075/yr at 8 kW) rather than 25D.

## Related Pages

Compare First Solar Inc equipment, CSI Solar Co Ltd CS1Y-390MS specs, utility payback rates, and NEC string calculators alongside First Solar Inc FS-6395.

[All First Solar Inc Certified Solar Models](https://epri-peac.com/solar-equipment/brands/first-solar-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From First Solar Inc

- [All First Solar Inc Specs](https://epri-peac.com/solar-equipment/brands/first-solar-inc/)
- [First Solar Inc FS-7550A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7550a-ft1/)
- [First Solar Inc FS-7550A-TR1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7550a-tr1/)
- [First Solar Inc FS-7545A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7545a-ft1/)
- [First Solar Inc FS-7545A-TR1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7545a-tr1/)
- [First Solar Inc FS-7540A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7540a-ft1/)
