title: "First Solar Inc FS-6390A Specs (390.0W, 214.8V Voc)"
url: https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-6390a/
description: "CEC datasheet for First Solar Inc FS-6390A: 390.0W STC, 214.8V Voc, 21-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# First Solar Inc FS-6390A — CEC Solar Module Specifications

Manufacturer: [**First Solar Inc**](https://epri-peac.com/solar-equipment/brands/first-solar-inc/) Registry: **CEC Verified Engineering Specification**

First Solar Inc FS-6390A is a 390.0 W STC (365.6 W PTC) CdTe solar module ranking #10,321 of 21,677 CEC listings (top 49.5%; higher than 50.5% of peers). It delivers 15.73% efficiency, 214.8 V Voc at 25 C, and 235.62 V cold Voc at -10 C (2 panels max per 600 V string).

- **STC Wattage** : 390.0 W

- **PTC Wattage** : 365.6 W

- **Voc @ 25C** : 214.8 V

- **Efficiency** : 15.73%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does First Solar Inc FS-6390A Compare Against Peer CEC Listings?

Solar engineering breakdown for First Solar Inc FS-6390A: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 390.0 W STC and 365.6 W PTC, First Solar Inc FS-6390A sits +5.0 W vs all-CEC median (top 49.5%; higher than 50.5% of peers) among 21,677 listed modules. Power density reaches 157.3 W/m2 (4.18 percentage points below 19.91% CEC median). Higher 214.8 V open-circuit voltage caps 600 V residential strings at 2 panels at 14 F (-10 C), whereas 1,000 V commercial inverters handle up to 4 panels in series. Alternative peer CSI Solar Co Ltd CS1Y-390MS rates 390.0 W.

## Where Does First Solar Inc FS-6390A Fall Across Listed CEC Models?

Distribution marker showing First Solar Inc FS-6390A (390.0 W) relative to the 385.0 W all-CEC solar panel median.

## What Dataset Percentiles Define First Solar Inc FS-6390A?

Dataset percentiles tracking First Solar Inc FS-6390A power output, thermal retention ratio, and aperture efficiency against 21,677 models.

## What Do the Dataset Ranks Show for First Solar Inc FS-6390A?

Benchmark highlights for First Solar Inc FS-6390A covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #10,321 / 21,677

### Top 49.5% STC Output

390.0 W STC (+5.0 W vs all-CEC median) vs 445.0 W CdTe median.

Eff #18,566

### 15.73% Aperture Efficiency

Power density 157.3 W/m2 (4.18 percentage points below 19.91% CEC median). PTC/STC ratio: 93.7% (rank #6,162).

NEC 690.7 Limit

### 2 Panels Max @ -10 C (600 V)

Cold Voc reaches 235.62 V at -10 C (471.2 V string) and 241.57 V at -20 C (2 max).

 8 kW Reference Array

### 21 Panels = 8,190 W STC

Occupies 52.1 m2 (561 sq ft) producing 7,678 W PTC; NEC 690.8 OCPD floor is 3.88 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 214.8 * (1 + (-0.277/100) * (-10 - 25)) = 235.62 V | OCPD = 1.56 * 2.49 = 3.88 A

Inputs from CEC Modules.csv for First Solar Inc FS-6390A: Voc=214.8 V, beta_Voc=-0.277%/C, Isc=2.49 A, STC=390.0 W, Area=2.48 m2.

**Result:** 2 panels max on 600 V (471.2 V); 21 panels for 8 kW (561 sq ft).

## What Are the Published CEC Specifications for First Solar Inc FS-6390A?

Official CEC datasheet figures for First Solar Inc FS-6390A (CdTe) used in utility interconnection and permit reviews. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Official California Energy Commission (NREL SAM) test parameters for First Solar Inc FS-6390A.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 390.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 365.6 W (93.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 214.8 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 2.49 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 173.9 V / 2.24 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.277 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 15.73% (2.48 m2) | Array roof footprint density |
| **Cell Count & Technology** | 264 cells (CdTe) | Monofacial backsheet |

## How Many First Solar Inc FS-6390A Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many First Solar Inc FS-6390A modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 16 | 6.24 kW | 427 sq ft | $1,562 | $2,641 |
| **8 kW Class** | 21 | 8.19 kW | 561 sq ft | $2,050 | $3,466 |
| **10 kW Class** | 26 | 10.14 kW | 694 sq ft | $2,538 | $4,292 |

## How Many First Solar Inc FS-6390A Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on First Solar Inc FS-6390A (235.62 V at 14 F).

Computed from Voc=214.8V and beta_Voc=-0.277%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 241.57 V | 2 panels | 483.1 V | 4 panels |
| **-10 C (14 F)** | 235.62 V | 2 panels | 471.2 V | 4 panels |
| **0 C (32 F)** | 229.67 V | 2 panels | 459.3 V | 4 panels |
| **25 C (77 F STC)** | 214.8 V | 2 panels | 429.6 V | 4 panels |

## Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-6390A?

Competing CEC solar panels closest to First Solar Inc FS-6390A in nameplate wattage and Voc, starting with CSI Solar Co Ltd CS1Y-390MS.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**CSI Solar Co Ltd CS1Y-390MS**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs1y-390ms/) CSI Solar Co Ltd | 390.0 W | Tie (0 W) | 51.9 V | 20.0% | 94.0% |
| [**BYD Company Limited BYD415MIK-36**](https://epri-peac.com/solar-equipment/modules/byd-company-limited/byd-company-limited-byd415mik-36/) BYD Company Limited | 395.0 W | +5.0 W | 50.06 V | 19.65% | 93.9% |
| [**ELITE Solar ET-M672BH395GL**](https://epri-peac.com/solar-equipment/modules/elite-solar/elite-solar-et-m672bh395gl/) ELITE Solar | 395.0 W | +5.0 W | 49.6 V | 19.36% | 93.2% |
| [**ELITE Solar ET-M672BH395WW**](https://epri-peac.com/solar-equipment/modules/elite-solar/elite-solar-et-m672bh395ww/) ELITE Solar | 395.0 W | +5.0 W | 49.5 V | 19.85% | 93.3% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-6390A?

Evaluate First Solar Inc FS-6390A (390.0 W STC, 214.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-6390A reaches 241.57 V per panel—exceeding 2 panels in series voids 600 V inverter warranties.
- Footprint constraint: 21 panels for an 8 kW build require 561 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (561 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of First Solar Inc FS-6390A carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### First Solar Inc FS-6390A 8 kW Residential Fit

Needs 21 modules (561 sq ft) with a 15 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 2 panels (-10 C) or 2 panels (-20 C), or compare CSI Solar Co Ltd CS1Y-390MS.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 365.6 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for First Solar Inc FS-6390A by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

### How many First Solar Inc FS-6390A panels fit on a 600 V winter solar string?

At -10 C (14 F), First Solar Inc FS-6390A cold Voc rises from 214.8 V to 235.62 V (beta_Voc -0.277%/C), capping a 600 V string at 2 panels (471.2 V).

### How much roof area does an 8 kW array of First Solar Inc FS-6390A need?

An 8 kW DC system uses 21 First Solar Inc FS-6390A modules (8,190 W STC / 7,678 W PTC), covering roughly 561 sq ft and saving ~$2,050/yr at 18.54 c/kWh.

### How does First Solar Inc FS-6390A compare against CSI Solar Co Ltd CS1Y-390MS?

First Solar Inc FS-6390A outputs 390.0 W STC (214.8 V Voc, rank #10,321 of 21,677), while CSI Solar Co Ltd CS1Y-390MS delivers 390.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare First Solar Inc equipment, CSI Solar Co Ltd CS1Y-390MS specs, utility payback rates, and NEC string calculators alongside First Solar Inc FS-6390A.

[All First Solar Inc Certified Solar Models](https://epri-peac.com/solar-equipment/brands/first-solar-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From First Solar Inc

- [All First Solar Inc Specs](https://epri-peac.com/solar-equipment/brands/first-solar-inc/)
- [First Solar Inc FS-7550A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7550a-ft1/)
- [First Solar Inc FS-7550A-TR1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7550a-tr1/)
- [First Solar Inc FS-7545A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7545a-ft1/)
- [First Solar Inc FS-7545A-TR1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7545a-tr1/)
- [First Solar Inc FS-7540A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7540a-ft1/)