title: "First Solar Inc FS-6385 Specs (385.0W, 214.3V Voc)"
url: https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-6385/
description: "CEC datasheet for First Solar Inc FS-6385: 385.0W STC, 214.3V Voc, 21-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# First Solar Inc FS-6385 — CEC Solar Module Specifications

Manufacturer: [**First Solar Inc**](https://epri-peac.com/solar-equipment/brands/first-solar-inc/) Registry: **CEC Verified Engineering Specification**

First Solar Inc FS-6385 is a 385.0 W STC (358.5 W PTC) CdTe solar module ranking #10,723 of 21,677 CEC listings (at all-CEC median; higher than 49.1% of peers). It delivers 15.52% efficiency, 214.3 V Voc at 25 C, and 235.23 V cold Voc at -10 C (2 panels max per 600 V string).

- **STC Wattage** : 385.0 W

- **PTC Wattage** : 358.5 W

- **Voc @ 25C** : 214.3 V

- **Efficiency** : 15.52%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does First Solar Inc FS-6385 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for First Solar Inc FS-6385 (CdTe) residential solar systems.

First Solar Inc FS-6385 delivers 155.2 W/m2 (4.39 percentage points below 19.91% CEC median) and strong 93.1% PTC-to-STC heat retention (#9,420 of 21,677), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 21 panels (561 sq ft). At -4 F (-20 C), string voltage climbs to 241.21 V per unit, capping 600 V circuits at 2 panels. Compare specs directly with CSI Solar Co Ltd CS1Y-390MS (390.0 W).

## Where Does First Solar Inc FS-6385 Fall Across Listed CEC Models?

Comparison of First Solar Inc FS-6385 (385.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

## What Dataset Percentiles Define First Solar Inc FS-6385?

Relative ranking of First Solar Inc FS-6385 across nameplate watts, 93.1% PTC thermal ratio, and module aperture efficiency.

## What Do the Dataset Ranks Show for First Solar Inc FS-6385?

Summary of First Solar Inc FS-6385 output rank, 8 kW array size (21 panels), efficiency rating, and 600 V string limit.

Rank #10,723 / 21,677

### 385.0 W STC · Higher Than 49.1%

385.0 W STC (equal to all-CEC median) vs 445.0 W CdTe median.

Eff #18,879

### 15.52% Aperture Efficiency

Power density 155.2 W/m2 (4.39 percentage points below 19.91% CEC median). PTC/STC ratio: 93.1% (rank #9,420).

NEC 690.7 Limit

### 2 Panels Max @ -10 C (600 V)

Cold Voc reaches 235.23 V at -10 C (470.5 V string) and 241.21 V at -20 C (2 max).

 8 kW Reference Array

### 21 Panels = 8,085 W STC

Occupies 52.1 m2 (561 sq ft) producing 7,528 W PTC; NEC 690.8 OCPD floor is 3.88 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 214.3 * (1 + (-0.279/100) * (-10 - 25)) = 235.23 V | OCPD = 1.56 * 2.49 = 3.88 A

Inputs from CEC Modules.csv for First Solar Inc FS-6385: Voc=214.3 V, beta_Voc=-0.279%/C, Isc=2.49 A, STC=385.0 W, Area=2.48 m2.

**Result:** 2 panels max on 600 V (470.5 V); 21 panels for 8 kW (561 sq ft).

## What Are the Published CEC Specifications for First Solar Inc FS-6385?

Complete CEC test sheet for First Solar Inc FS-6385 including Isc (2.49 A), Voc (214.3 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for First Solar Inc FS-6385.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 385.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 358.5 W (93.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 214.3 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 2.49 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 172.8 V / 2.23 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.279 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 15.52% (2.48 m2) | Array roof footprint density |
| **Cell Count & Technology** | 264 cells (CdTe) | Monofacial backsheet |

## How Many First Solar Inc FS-6385 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using First Solar Inc FS-6385.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 16 | 6.16 kW | 427 sq ft | $1,542 | $2,607 |
| **8 kW Class** | 21 | 8.09 kW | 561 sq ft | $2,025 | $3,424 |
| **10 kW Class** | 26 | 10.01 kW | 694 sq ft | $2,505 | $4,236 |

## How Many First Solar Inc FS-6385 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for First Solar Inc FS-6385 (214.3 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=214.3V and beta_Voc=-0.279%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 241.21 V | 2 panels | 482.4 V | 4 panels |
| **-10 C (14 F)** | 235.23 V | 2 panels | 470.5 V | 4 panels |
| **0 C (32 F)** | 229.25 V | 2 panels | 458.5 V | 4 panels |
| **25 C (77 F STC)** | 214.3 V | 2 panels | 428.6 V | 4 panels |

## Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-6385?

Four comparable CEC modules such as CSI Solar Co Ltd CS1Y-390MS (390.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**CSI Solar Co Ltd CS1Y-390MS**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs1y-390ms/) CSI Solar Co Ltd | 390.0 W | +5.0 W | 51.9 V | 20.0% | 94.0% |
| [**EMMVEE Photovoltaic Power Private Limited E385M72**](https://epri-peac.com/solar-equipment/modules/emmvee-photovoltaic-power-private-limited/emmvee-photovoltaic-power-private-limited-e385m72/) EMMVEE Photovoltaic Power Private Limited | 385.0 W | Tie (0 W) | 48.9 V | 19.32% | 92.0% |
| [**Boviet Solar Technology Co Ltd BVM6612M-385-H**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6612m-385-h/) Boviet Solar Technology Co Ltd | 385.0 W | Tie (0 W) | 48.5 V | 19.85% | 93.1% |
| [**Boviet Solar Technology Co Ltd BVM6612M-W5-385-H**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6612m-w5-385-h/) Boviet Solar Technology Co Ltd | 385.0 W | Tie (0 W) | 48.5 V | 19.85% | 93.1% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-6385?

Evaluate First Solar Inc FS-6385 (385.0 W STC, 214.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-6385 reaches 241.21 V per panel—exceeding 2 panels in series voids 600 V inverter warranties.
- Footprint constraint: 21 panels for an 8 kW build require 561 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 21 panels (561 sq ft).
- 2026 tax credit baseline: cash residential installs of First Solar Inc FS-6385 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### First Solar Inc FS-6385 8 kW Residential Fit

Needs 21 modules (561 sq ft) with a 15 A string OCPD, offsetting ~$2,025/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 2 panels (-10 C) or 2 panels (-20 C), or compare CSI Solar Co Ltd CS1Y-390MS.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 358.5 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for First Solar Inc FS-6385 by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

### How many First Solar Inc FS-6385 panels fit on a 600 V winter solar string?

At -10 C (14 F), First Solar Inc FS-6385 cold Voc rises from 214.3 V to 235.23 V (beta_Voc -0.279%/C), capping a 600 V string at 2 panels (470.5 V).

### How much roof area does an 8 kW array of First Solar Inc FS-6385 need?

An 8 kW DC system uses 21 First Solar Inc FS-6385 modules (8,085 W STC / 7,528 W PTC), covering roughly 561 sq ft and saving ~$2,025/yr at 18.54 c/kWh.

### How does First Solar Inc FS-6385 compare against CSI Solar Co Ltd CS1Y-390MS?

First Solar Inc FS-6385 outputs 385.0 W STC (214.3 V Voc, rank #10,723 of 21,677), while CSI Solar Co Ltd CS1Y-390MS delivers 390.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare First Solar Inc equipment, CSI Solar Co Ltd CS1Y-390MS specs, utility payback rates, and NEC string calculators alongside First Solar Inc FS-6385.

[All First Solar Inc Certified Solar Models](https://epri-peac.com/solar-equipment/brands/first-solar-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From First Solar Inc

- [All First Solar Inc Specs](https://epri-peac.com/solar-equipment/brands/first-solar-inc/)
- [First Solar Inc FS-7550A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7550a-ft1/)
- [First Solar Inc FS-7550A-TR1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7550a-tr1/)
- [First Solar Inc FS-7545A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7545a-ft1/)
- [First Solar Inc FS-7545A-TR1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7545a-tr1/)
- [First Solar Inc FS-7540A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7540a-ft1/)