title: "First Solar Inc FS-4120-3 Specs (120.0W, 88.7V Voc)"
url: https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-4120-3/
description: "CEC datasheet for First Solar Inc FS-4120-3: 120.0W STC, 88.7V Voc, 67-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# First Solar Inc FS-4120-3 — CEC Solar Module Specifications

Manufacturer: [**First Solar Inc**](https://epri-peac.com/solar-equipment/brands/first-solar-inc/) Registry: **CEC Verified Engineering Specification**

First Solar Inc FS-4120-3 is a 120.0 W STC (112.1 W PTC) Thin Film solar module ranking #21,493 of 21,677 CEC listings (below all-CEC median; higher than 0.8% of peers). It delivers 16.67% efficiency, 88.7 V Voc at 25 C, and 99.85 V cold Voc at -10 C (6 panels max per 600 V string).

- **STC Wattage** : 120.0 W

- **PTC Wattage** : 112.1 W

- **Voc @ 25C** : 88.7 V

- **Efficiency** : 16.67%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does First Solar Inc FS-4120-3 Compare Against Peer CEC Listings?

Solar engineering breakdown for First Solar Inc FS-4120-3: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 106 Thin Film listings from First Solar Inc and peers, First Solar Inc FS-4120-3 stands 2.5 W above the 117.5 W Thin Film median and strong 93.4% PTC-to-STC heat retention (#7,716 of 21,677). Sizing 6 kW (50 panels) to 10 kW (84 panels) yields $1,502-$2,523/yr in baseline US bill offset. Higher 88.7 V open-circuit voltage caps 600 V residential strings at 6 panels at 14 F (-10 C).

## Where Does First Solar Inc FS-4120-3 Fall Across Listed CEC Models?

Distribution marker showing First Solar Inc FS-4120-3 (120.0 W) relative to the 385.0 W all-CEC solar panel median.

## What Dataset Percentiles Define First Solar Inc FS-4120-3?

Dataset percentiles tracking First Solar Inc FS-4120-3 power output, thermal retention ratio, and aperture efficiency against 21,677 models.

## What Do the Dataset Ranks Show for First Solar Inc FS-4120-3?

Benchmark highlights for First Solar Inc FS-4120-3 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #21,493 / 21,677

### 120.0 W STC · Higher Than 0.8%

120.0 W STC (-265.0 W vs all-CEC median) vs 117.5 W Thin Film median.

Eff #17,034

### 16.67% Aperture Efficiency

Power density 166.7 W/m2 (3.24 percentage points below 19.91% CEC median). PTC/STC ratio: 93.4% (rank #7,716).

NEC 690.7 Limit

### 6 Panels Max @ -10 C (600 V)

Cold Voc reaches 99.85 V at -10 C (599.1 V string) and 103.03 V at -20 C (5 max).

 8 kW Reference Array

### 67 Panels = 8,040 W STC

Occupies 48.2 m2 (519 sq ft) producing 7,511 W PTC; NEC 690.8 OCPD floor is 2.87 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 88.7 * (1 + (-0.359/100) * (-10 - 25)) = 99.85 V | OCPD = 1.56 * 1.84 = 2.87 A

Inputs from CEC Modules.csv for First Solar Inc FS-4120-3: Voc=88.7 V, beta_Voc=-0.359%/C, Isc=1.84 A, STC=120.0 W, Area=0.72 m2.

**Result:** 6 panels max on 600 V (599.1 V); 67 panels for 8 kW (519 sq ft).

## What Are the Published CEC Specifications for First Solar Inc FS-4120-3?

Official CEC datasheet figures for First Solar Inc FS-4120-3 (Thin Film) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for First Solar Inc FS-4120-3.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 120.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 112.1 W (93.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 88.7 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 1.84 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 70.8 V / 1.7 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.359 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 16.67% (0.72 m2) | Array roof footprint density |
| **Cell Count & Technology** | 216 cells (Thin Film) | Monofacial backsheet |

## How Many First Solar Inc FS-4120-3 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many First Solar Inc FS-4120-3 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 50 | 6.0 kW | 388 sq ft | $1,502 | $2,539 |
| **8 kW Class** | 67 | 8.04 kW | 519 sq ft | $2,012 | $3,403 |
| **10 kW Class** | 84 | 10.08 kW | 651 sq ft | $2,523 | $4,266 |

## How Many First Solar Inc FS-4120-3 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on First Solar Inc FS-4120-3 (99.85 V at 14 F).

Computed from Voc=88.7V and beta_Voc=-0.359%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 103.03 V | 5 panels | 515.1 V | 9 panels |
| **-10 C (14 F)** | 99.85 V | 6 panels | 599.1 V | 10 panels |
| **0 C (32 F)** | 96.66 V | 6 panels | 580.0 V | 10 panels |
| **25 C (77 F STC)** | 88.7 V | 6 panels | 532.2 V | 11 panels |

## Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-4120-3?

Competing CEC solar panels closest to First Solar Inc FS-4120-3 in nameplate wattage and Voc, starting with Toledo Solar Inc TS1.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Toledo Solar Inc TS1**](https://epri-peac.com/solar-equipment/modules/toledo-solar-inc/toledo-solar-inc-ts1/) Toledo Solar Inc | 115.0 W | -5.0 W | 87.1 V | 15.97% | 92.9% |
| [**Caterpillar Inc PVT112**](https://epri-peac.com/solar-equipment/modules/caterpillar-inc/caterpillar-inc-pvt112/) Caterpillar Inc | 112.5 W | -7.5 W | 87.7 V | 15.62% | 92.9% |
| [**Caterpillar Inc PVT112 ARC**](https://epri-peac.com/solar-equipment/modules/caterpillar-inc/caterpillar-inc-pvt112-arc/) Caterpillar Inc | 112.5 W | -7.5 W | 87.7 V | 15.62% | 92.9% |
| [**Applied Materials 1/4 Size Single Junction Version 10**](https://epri-peac.com/solar-equipment/modules/applied-materials/applied-materials-1-4-size-single-junction-version-10/) Applied Materials | 116.0 W | -4.0 W | 96.2 V | 8.11% | 93.0% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-4120-3?

Evaluate First Solar Inc FS-4120-3 (120.0 W STC, 88.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-4120-3 reaches 103.03 V per panel—exceeding 5 panels in series voids 600 V inverter warranties.
- Footprint constraint: 67 panels for an 8 kW build require 519 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 67 panels (519 sq ft).
- 2026 tax credit baseline: cash residential installs of First Solar Inc FS-4120-3 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### First Solar Inc FS-4120-3 8 kW Residential Fit

Needs 67 modules (519 sq ft) with a 15 A string OCPD, offsetting ~$2,012/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 6 panels (-10 C) or 5 panels (-20 C), or compare Toledo Solar Inc TS1.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 112.1 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for First Solar Inc FS-4120-3 by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for First Solar Inc FS-4120-3?

Multiplying First Solar Inc FS-4120-3's 1.84 A short-circuit current by 1.56 equals 2.87 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

### Can First Solar Inc FS-4120-3 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 99.85 V cold Voc at 14 F and handles 1.84 A Isc; string inverters cap First Solar Inc FS-4120-3 at 6 panels on 600 V.

### Is First Solar Inc FS-4120-3 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of First Solar Inc FS-4120-3 rely on utility bill offset (~$2,012/yr at 8 kW) rather than 25D.

## Related Pages

Compare First Solar Inc equipment, Toledo Solar Inc TS1 specs, utility payback rates, and NEC string calculators alongside First Solar Inc FS-4120-3.

[All First Solar Inc Certified Solar Models](https://epri-peac.com/solar-equipment/brands/first-solar-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From First Solar Inc

- [All First Solar Inc Specs](https://epri-peac.com/solar-equipment/brands/first-solar-inc/)
- [First Solar Inc FS-7550A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7550a-ft1/)
- [First Solar Inc FS-7550A-TR1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7550a-tr1/)
- [First Solar Inc FS-7545A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7545a-ft1/)
- [First Solar Inc FS-7545A-TR1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7545a-tr1/)
- [First Solar Inc FS-7540A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7540a-ft1/)