---
title: "First Solar Inc FS-4117-3 Specs (117.5W, 88.1V Voc)"
url: https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-4117-3/
description: "CEC datasheet for First Solar Inc FS-4117-3: 117.5W STC, 88.1V Voc, 69-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# First Solar Inc FS-4117-3 — CEC Solar Module Specifications

Manufacturer: [**First Solar Inc**](https://epri-peac.com/solar-equipment/brands/first-solar-inc/) Registry: **CEC Verified Engineering Specification**

First Solar Inc FS-4117-3 is a 117.5 W STC (109.7 W PTC) Thin Film solar module ranking #21,501 of 21,677 CEC listings (below all-CEC median; higher than 0.8% of peers). It delivers 16.32% efficiency, 88.1 V Voc at 25 C, and 99.17 V cold Voc at -10 C (6 panels max per 600 V string).

- **STC Wattage** : 117.5 W

- **PTC Wattage** : 109.7 W

- **Voc @ 25C** : 88.1 V

- **Efficiency** : 16.32%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does First Solar Inc FS-4117-3 Compare Against Peer CEC Listings?

How First Solar Inc First Solar Inc FS-4117-3 handles rooftop heat (109.7 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, First Solar Inc FS-4117-3 exhibits 1.83 A short-circuit current, requiring a 2.85 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #21,501 of 21,677 (equal to the 117.5 W Thin Film median), this compact residential or specialty off-grid module covers 49.7 m2 for an 8 kW system (86 panels for 10 kW). Higher 88.1 V open-circuit voltage caps 600 V residential strings at 6 panels at 14 F (-10 C).

## Where Does First Solar Inc FS-4117-3 Fall Across Listed CEC Models?

Where First Solar Inc FS-4117-3 (117.5 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define First Solar Inc FS-4117-3?

Percentile placement of First Solar Inc FS-4117-3 across power density (163.2 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for First Solar Inc FS-4117-3?

Four critical engineering numbers homeowners and solar installers check first when reviewing First Solar Inc FS-4117-3 specifications. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Rank #21,501 / 21,677

### 117.5 W STC · Higher Than 0.8%

117.5 W STC (-267.5 W vs all-CEC median) vs 117.5 W Thin Film median.

Eff #17,631

### 16.32% Aperture Efficiency

Power density 163.2 W/m2 (3.59 percentage points below 19.91% CEC median). PTC/STC ratio: 93.4% (rank #7,716).

NEC 690.7 Limit

### 6 Panels Max @ -10 C (600 V)

Cold Voc reaches 99.17 V at -10 C (595.0 V string) and 102.33 V at -20 C (5 max).

 8 kW Reference Array

### 69 Panels = 8,108 W STC

Occupies 49.7 m2 (535 sq ft) producing 7,569 W PTC; NEC 690.8 OCPD floor is 2.85 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 88.1 * (1 + (-0.359/100) * (-10 - 25)) = 99.17 V | OCPD = 1.56 * 1.83 = 2.85 A

Inputs from CEC Modules.csv for First Solar Inc FS-4117-3: Voc=88.1 V, beta_Voc=-0.359%/C, Isc=1.83 A, STC=117.5 W, Area=0.72 m2.

**Result:** 6 panels max on 600 V (595.0 V); 69 panels for 8 kW (535 sq ft).

## What Are the Published CEC Specifications for First Solar Inc FS-4117-3?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for First Solar Inc FS-4117-3.

Official California Energy Commission (NREL SAM) test parameters for First Solar Inc FS-4117-3.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 117.5 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 109.7 W (93.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 88.1 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 1.83 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 70.1 V / 1.68 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.359 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 16.32% (0.72 m2) | Array roof footprint density |
| **Cell Count & Technology** | 216 cells (Thin Film) | Monofacial backsheet |

## How Many First Solar Inc FS-4117-3 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using First Solar Inc FS-4117-3 (117.5 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 52 | 6.11 kW | 403 sq ft | $1,529 | $2,586 |
| **8 kW Class** | 69 | 8.11 kW | 535 sq ft | $2,030 | $3,432 |
| **10 kW Class** | 86 | 10.11 kW | 667 sq ft | $2,530 | $4,279 |

## How Many First Solar Inc FS-4117-3 Modules Fit in a Cold-Weather String?

Maximum series module counts for First Solar Inc FS-4117-3 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=88.1V and beta_Voc=-0.359%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 102.33 V | 5 panels | 511.6 V | 9 panels |
| **-10 C (14 F)** | 99.17 V | 6 panels | 595.0 V | 10 panels |
| **0 C (32 F)** | 96.01 V | 6 panels | 576.1 V | 10 panels |
| **25 C (77 F STC)** | 88.1 V | 6 panels | 528.6 V | 11 panels |

## Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-4117-3?

Alternative CEC solar modules from competing brands near First Solar Inc FS-4117-3 (117.5 W), including Toledo Solar Inc TS1.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Toledo Solar Inc TS1**](https://epri-peac.com/solar-equipment/modules/toledo-solar-inc/toledo-solar-inc-ts1/) Toledo Solar Inc | 115.0 W | -2.5 W | 87.1 V | 15.97% | 92.9% |
| [**Caterpillar Inc PVT112**](https://epri-peac.com/solar-equipment/modules/caterpillar-inc/caterpillar-inc-pvt112/) Caterpillar Inc | 112.5 W | -5.0 W | 87.7 V | 15.62% | 92.9% |
| [**Caterpillar Inc PVT112 ARC**](https://epri-peac.com/solar-equipment/modules/caterpillar-inc/caterpillar-inc-pvt112-arc/) Caterpillar Inc | 112.5 W | -5.0 W | 87.7 V | 15.62% | 92.9% |
| [**Applied Materials 1/4 Size Single Junction Version 10**](https://epri-peac.com/solar-equipment/modules/applied-materials/applied-materials-1-4-size-single-junction-version-10/) Applied Materials | 116.0 W | -1.5 W | 96.2 V | 8.11% | 93.0% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-4117-3?

Evaluate First Solar Inc FS-4117-3 (117.5 W STC, 88.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-4117-3 reaches 102.33 V per panel—exceeding 5 panels in series voids 600 V inverter warranties.
- Footprint constraint: 69 panels for an 8 kW build require 535 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 69 panels (535 sq ft).
- 2026 tax credit baseline: cash residential installs of First Solar Inc FS-4117-3 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### First Solar Inc FS-4117-3 8 kW Residential Fit

Needs 69 modules (535 sq ft) with a 15 A string OCPD, offsetting ~$2,030/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 6 panels (-10 C) or 5 panels (-20 C), or compare Toledo Solar Inc TS1.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 109.7 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for First Solar Inc FS-4117-3 by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is First Solar Inc FS-4117-3 PTC wattage (109.7 W) lower than STC (117.5 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 109.7 W PTC (93.4% retention) across First Solar Inc FS-4117-3's 0.72 m2 aperture.

### Who should skip First Solar Inc FS-4117-3 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 69 First Solar Inc FS-4117-3 panels (535 sq ft) leave unusable roof gaps vs. Toledo Solar Inc TS1.

### What is the 1,000 V commercial string limit for First Solar Inc FS-4117-3?

On 1,000 V commercial inverters at -10 C (99.17 V cold Voc), First Solar Inc FS-4117-3 fits up to 10 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting First Solar Inc FS-4117-3.

## Related Pages

Compare First Solar Inc equipment, Toledo Solar Inc TS1 specs, utility payback rates, and NEC string calculators alongside First Solar Inc FS-4117-3.

[All First Solar Inc Certified Solar Models](https://epri-peac.com/solar-equipment/brands/first-solar-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From First Solar Inc

- [All First Solar Inc Specs](https://epri-peac.com/solar-equipment/brands/first-solar-inc/)
- [First Solar Inc FS-7550A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7550a-ft1/)
- [First Solar Inc FS-7550A-TR1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7550a-tr1/)
- [First Solar Inc FS-7545A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7545a-ft1/)
- [First Solar Inc FS-7545A-TR1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7545a-tr1/)
- [First Solar Inc FS-7540A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7540a-ft1/)
