title: "First Solar Inc FS-4115-2 Specs (115.0W, 87.8V Voc)"
url: https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-4115-2/
description: "CEC datasheet for First Solar Inc FS-4115-2: 115.0W STC, 87.8V Voc, 70-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# First Solar Inc FS-4115-2 — CEC Solar Module Specifications

Manufacturer: [**First Solar Inc**](https://epri-peac.com/solar-equipment/brands/first-solar-inc/) Registry: **CEC Verified Engineering Specification**

First Solar Inc FS-4115-2 is a 115.0 W STC (105.2 W PTC) Thin Film solar module ranking #21,511 of 21,677 CEC listings (below all-CEC median; higher than 0.7% of peers). It delivers 15.97% efficiency, 87.8 V Voc at 25 C, and 98.71 V cold Voc at -10 C (6 panels max per 600 V string).

- **STC Wattage** : 115.0 W

- **PTC Wattage** : 105.2 W

- **Voc @ 25C** : 87.8 V

- **Efficiency** : 15.97%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does First Solar Inc FS-4115-2 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for First Solar Inc FS-4115-2 (Thin Film) residential solar systems.

Homeowners evaluating First Solar Inc FS-4115-2 need 53 panels for 6 kW or 70 panels (543 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 70 panels (543 sq ft). Under NEC 690.7(A), beta_Voc (-0.355%/C) pushes open-circuit voltage to 98.71 V at 14 F and 101.83 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

## Where Does First Solar Inc FS-4115-2 Fall Across Listed CEC Models?

Comparison of First Solar Inc FS-4115-2 (115.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

## What Dataset Percentiles Define First Solar Inc FS-4115-2?

Relative ranking of First Solar Inc FS-4115-2 across nameplate watts, 91.5% PTC thermal ratio, and module aperture efficiency.

## What Do the Dataset Ranks Show for First Solar Inc FS-4115-2?

Summary of First Solar Inc FS-4115-2 output rank, 8 kW array size (70 panels), efficiency rating, and 600 V string limit.

Rank #21,511 / 21,677

### 115.0 W STC · Higher Than 0.7%

115.0 W STC (-270.0 W vs all-CEC median) vs 117.5 W Thin Film median.

Eff #18,237

### 15.97% Aperture Efficiency

Power density 159.7 W/m2 (3.94 percentage points below 19.91% CEC median). PTC/STC ratio: 91.5% (rank #15,584).

NEC 690.7 Limit

### 6 Panels Max @ -10 C (600 V)

Cold Voc reaches 98.71 V at -10 C (592.3 V string) and 101.83 V at -20 C (5 max).

 8 kW Reference Array

### 70 Panels = 8,050 W STC

Occupies 50.4 m2 (543 sq ft) producing 7,364 W PTC; NEC 690.8 OCPD floor is 2.78 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 87.8 * (1 + (-0.355/100) * (-10 - 25)) = 98.71 V | OCPD = 1.56 * 1.78 = 2.78 A

Inputs from CEC Modules.csv for First Solar Inc FS-4115-2: Voc=87.8 V, beta_Voc=-0.355%/C, Isc=1.78 A, STC=115.0 W, Area=0.72 m2.

**Result:** 6 panels max on 600 V (592.3 V); 70 panels for 8 kW (543 sq ft).

## What Are the Published CEC Specifications for First Solar Inc FS-4115-2?

Complete CEC test sheet for First Solar Inc FS-4115-2 including Isc (1.78 A), Voc (87.8 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for First Solar Inc FS-4115-2.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 115.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 105.2 W (91.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 87.8 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 1.78 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 70.5 V / 1.63 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.355 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 15.97% (0.72 m2) | Array roof footprint density |
| **Cell Count & Technology** | 216 cells (Thin Film) | Monofacial backsheet |

## How Many First Solar Inc FS-4115-2 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using First Solar Inc FS-4115-2.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 53 | 6.09 kW | 411 sq ft | $1,524 | $2,577 |
| **8 kW Class** | 70 | 8.05 kW | 543 sq ft | $2,015 | $3,407 |
| **10 kW Class** | 87 | 10.01 kW | 674 sq ft | $2,505 | $4,236 |

## How Many First Solar Inc FS-4115-2 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for First Solar Inc FS-4115-2 (87.8 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=87.8V and beta_Voc=-0.355%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 101.83 V | 5 panels | 509.1 V | 9 panels |
| **-10 C (14 F)** | 98.71 V | 6 panels | 592.3 V | 10 panels |
| **0 C (32 F)** | 95.59 V | 6 panels | 573.5 V | 10 panels |
| **25 C (77 F STC)** | 87.8 V | 6 panels | 526.8 V | 11 panels |

## Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-4115-2?

Four comparable CEC modules such as Toledo Solar Inc TS1 (115.0 W) for side-by-side solar quote checks. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Toledo Solar Inc TS1**](https://epri-peac.com/solar-equipment/modules/toledo-solar-inc/toledo-solar-inc-ts1/) Toledo Solar Inc | 115.0 W | Tie (0 W) | 87.1 V | 15.97% | 92.9% |
| [**Caterpillar Inc PVT112**](https://epri-peac.com/solar-equipment/modules/caterpillar-inc/caterpillar-inc-pvt112/) Caterpillar Inc | 112.5 W | -2.5 W | 87.7 V | 15.62% | 92.9% |
| [**Caterpillar Inc PVT112 ARC**](https://epri-peac.com/solar-equipment/modules/caterpillar-inc/caterpillar-inc-pvt112-arc/) Caterpillar Inc | 112.5 W | -2.5 W | 87.7 V | 15.62% | 92.9% |
| [**T-Solar Global TS102**](https://epri-peac.com/solar-equipment/modules/t-solar-global/t-solar-global-ts102/) T-Solar Global | 102.5 W | -12.5 W | 93.0 V | 7.19% | 93.0% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-4115-2?

Evaluate First Solar Inc FS-4115-2 (115.0 W STC, 87.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-4115-2 reaches 101.83 V per panel—exceeding 5 panels in series voids 600 V inverter warranties.
- Footprint constraint: 70 panels for an 8 kW build require 543 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 70 panels (543 sq ft).
- 2026 tax credit baseline: cash residential installs of First Solar Inc FS-4115-2 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### First Solar Inc FS-4115-2 8 kW Residential Fit

Needs 70 modules (543 sq ft) with a 15 A string OCPD, offsetting ~$2,015/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 6 panels (-10 C) or 5 panels (-20 C), or compare Toledo Solar Inc TS1.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 105.2 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for First Solar Inc FS-4115-2 by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is First Solar Inc FS-4115-2 PTC wattage (105.2 W) lower than STC (115.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 105.2 W PTC (91.5% retention) across First Solar Inc FS-4115-2's 0.72 m2 aperture.

### Who should skip First Solar Inc FS-4115-2 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 70 First Solar Inc FS-4115-2 panels (543 sq ft) leave unusable roof gaps vs. Toledo Solar Inc TS1.

### What is the 1,000 V commercial string limit for First Solar Inc FS-4115-2?

On 1,000 V commercial inverters at -10 C (98.71 V cold Voc), First Solar Inc FS-4115-2 fits up to 10 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting First Solar Inc FS-4115-2.

## Related Pages

Compare First Solar Inc equipment, Toledo Solar Inc TS1 specs, utility payback rates, and NEC string calculators alongside First Solar Inc FS-4115-2.

[All First Solar Inc Certified Solar Models](https://epri-peac.com/solar-equipment/brands/first-solar-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From First Solar Inc

- [All First Solar Inc Specs](https://epri-peac.com/solar-equipment/brands/first-solar-inc/)
- [First Solar Inc FS-7550A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7550a-ft1/)
- [First Solar Inc FS-7550A-TR1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7550a-tr1/)
- [First Solar Inc FS-7545A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7545a-ft1/)
- [First Solar Inc FS-7545A-TR1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7545a-tr1/)
- [First Solar Inc FS-7540A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7540a-ft1/)