title: "First Solar Inc FS-4110-3 Specs (110.0W, 86.4V Voc)"
url: https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-4110-3/
description: "CEC datasheet for First Solar Inc FS-4110-3: 110.0W STC, 86.4V Voc, 73-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# First Solar Inc FS-4110-3 — CEC Solar Module Specifications

Manufacturer: [**First Solar Inc**](https://epri-peac.com/solar-equipment/brands/first-solar-inc/) Registry: **CEC Verified Engineering Specification**

First Solar Inc FS-4110-3 is a 110.0 W STC (102.6 W PTC) Thin Film solar module ranking #21,527 of 21,677 CEC listings (below all-CEC median; higher than 0.7% of peers). It delivers 15.28% efficiency, 86.4 V Voc at 25 C, and 97.26 V cold Voc at -10 C (6 panels max per 600 V string).

- **STC Wattage** : 110.0 W

- **PTC Wattage** : 102.6 W

- **Voc @ 25C** : 86.4 V

- **Efficiency** : 15.28%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does First Solar Inc FS-4110-3 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for First Solar Inc FS-4110-3 (Thin Film) residential solar systems.

First Solar Inc FS-4110-3 delivers 152.8 W/m2 (4.63 percentage points below 19.91% CEC median) and strong 93.3% PTC-to-STC heat retention (#8,323 of 21,677), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 73 panels (566 sq ft). At -4 F (-20 C), string voltage climbs to 100.36 V per unit, capping 600 V circuits at 5 panels. Compare specs directly with Caterpillar Inc PVT112 (112.5 W).

## Where Does First Solar Inc FS-4110-3 Fall Across Listed CEC Models?

Comparison of First Solar Inc FS-4110-3 (110.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

## What Dataset Percentiles Define First Solar Inc FS-4110-3?

Relative ranking of First Solar Inc FS-4110-3 across nameplate watts, 93.3% PTC thermal ratio, and module aperture efficiency.

## What Do the Dataset Ranks Show for First Solar Inc FS-4110-3?

Summary of First Solar Inc FS-4110-3 output rank, 8 kW array size (73 panels), efficiency rating, and 600 V string limit.

Rank #21,527 / 21,677

### 110.0 W STC · Higher Than 0.7%

110.0 W STC (-275.0 W vs all-CEC median) vs 117.5 W Thin Film median.

Eff #19,278

### 15.28% Aperture Efficiency

Power density 152.8 W/m2 (4.63 percentage points below 19.91% CEC median). PTC/STC ratio: 93.3% (rank #8,323).

NEC 690.7 Limit

### 6 Panels Max @ -10 C (600 V)

Cold Voc reaches 97.26 V at -10 C (583.6 V string) and 100.36 V at -20 C (5 max).

 8 kW Reference Array

### 73 Panels = 8,030 W STC

Occupies 52.6 m2 (566 sq ft) producing 7,490 W PTC; NEC 690.8 OCPD floor is 2.84 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 86.4 * (1 + (-0.359/100) * (-10 - 25)) = 97.26 V | OCPD = 1.56 * 1.82 = 2.84 A

Inputs from CEC Modules.csv for First Solar Inc FS-4110-3: Voc=86.4 V, beta_Voc=-0.359%/C, Isc=1.82 A, STC=110.0 W, Area=0.72 m2.

**Result:** 6 panels max on 600 V (583.6 V); 73 panels for 8 kW (566 sq ft).

## What Are the Published CEC Specifications for First Solar Inc FS-4110-3?

Complete CEC test sheet for First Solar Inc FS-4110-3 including Isc (1.82 A), Voc (86.4 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for First Solar Inc FS-4110-3.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 110.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 102.6 W (93.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 86.4 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 1.82 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 67.8 V / 1.62 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.359 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 15.28% (0.72 m2) | Array roof footprint density |
| **Cell Count & Technology** | 216 cells (Thin Film) | Monofacial backsheet |

## How Many First Solar Inc FS-4110-3 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using First Solar Inc FS-4110-3.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 55 | 6.05 kW | 426 sq ft | $1,514 | $2,561 |
| **8 kW Class** | 73 | 8.03 kW | 566 sq ft | $2,010 | $3,398 |
| **10 kW Class** | 91 | 10.01 kW | 705 sq ft | $2,505 | $4,236 |

## How Many First Solar Inc FS-4110-3 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for First Solar Inc FS-4110-3 (86.4 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=86.4V and beta_Voc=-0.359%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 100.36 V | 5 panels | 501.8 V | 9 panels |
| **-10 C (14 F)** | 97.26 V | 6 panels | 583.6 V | 10 panels |
| **0 C (32 F)** | 94.15 V | 6 panels | 564.9 V | 10 panels |
| **25 C (77 F STC)** | 86.4 V | 6 panels | 518.4 V | 11 panels |

## Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-4110-3?

Four comparable CEC modules such as Caterpillar Inc PVT112 (112.5 W) for side-by-side solar quote checks. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Caterpillar Inc PVT112**](https://epri-peac.com/solar-equipment/modules/caterpillar-inc/caterpillar-inc-pvt112/) Caterpillar Inc | 112.5 W | +2.5 W | 87.7 V | 15.62% | 92.9% |
| [**Caterpillar Inc PVT112 ARC**](https://epri-peac.com/solar-equipment/modules/caterpillar-inc/caterpillar-inc-pvt112-arc/) Caterpillar Inc | 112.5 W | +2.5 W | 87.7 V | 15.62% | 92.9% |
| [**Toledo Solar Inc TS1**](https://epri-peac.com/solar-equipment/modules/toledo-solar-inc/toledo-solar-inc-ts1/) Toledo Solar Inc | 115.0 W | +5.0 W | 87.1 V | 15.97% | 92.9% |
| [**T-Solar Global TS102**](https://epri-peac.com/solar-equipment/modules/t-solar-global/t-solar-global-ts102/) T-Solar Global | 102.5 W | -7.5 W | 93.0 V | 7.19% | 93.0% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-4110-3?

Evaluate First Solar Inc FS-4110-3 (110.0 W STC, 86.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-4110-3 reaches 100.36 V per panel—exceeding 5 panels in series voids 600 V inverter warranties.
- Footprint constraint: 73 panels for an 8 kW build require 566 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 73 panels (566 sq ft).
- 2026 tax credit baseline: cash residential installs of First Solar Inc FS-4110-3 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### First Solar Inc FS-4110-3 8 kW Residential Fit

Needs 73 modules (566 sq ft) with a 15 A string OCPD, offsetting ~$2,010/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 6 panels (-10 C) or 5 panels (-20 C), or compare Caterpillar Inc PVT112.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 102.6 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for First Solar Inc FS-4110-3 by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

### How many First Solar Inc FS-4110-3 panels fit on a 600 V winter solar string?

At -10 C (14 F), First Solar Inc FS-4110-3 cold Voc rises from 86.4 V to 97.26 V (beta_Voc -0.359%/C), capping a 600 V string at 6 panels (583.6 V).

### How much roof area does an 8 kW array of First Solar Inc FS-4110-3 need?

An 8 kW DC system uses 73 First Solar Inc FS-4110-3 modules (8,030 W STC / 7,490 W PTC), covering roughly 566 sq ft and saving ~$2,010/yr at 18.54 c/kWh.

### How does First Solar Inc FS-4110-3 compare against Caterpillar Inc PVT112?

First Solar Inc FS-4110-3 outputs 110.0 W STC (86.4 V Voc, rank #21,527 of 21,677), while Caterpillar Inc PVT112 delivers 112.5 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare First Solar Inc equipment, Caterpillar Inc PVT112 specs, utility payback rates, and NEC string calculators alongside First Solar Inc FS-4110-3.

[All First Solar Inc Certified Solar Models](https://epri-peac.com/solar-equipment/brands/first-solar-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From First Solar Inc

- [All First Solar Inc Specs](https://epri-peac.com/solar-equipment/brands/first-solar-inc/)
- [First Solar Inc FS-7550A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7550a-ft1/)
- [First Solar Inc FS-7550A-TR1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7550a-tr1/)
- [First Solar Inc FS-7545A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7545a-ft1/)
- [First Solar Inc FS-7545A-TR1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7545a-tr1/)
- [First Solar Inc FS-7540A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7540a-ft1/)