---
title: "First Solar Inc FS-4107A-2 Specs (107.5W, 86.6V Voc)"
url: https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-4107a-2/
description: "CEC datasheet for First Solar Inc FS-4107A-2: 107.5W STC, 86.6V Voc, 75-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# First Solar Inc FS-4107A-2 — CEC Solar Module Specifications

Manufacturer: [**First Solar Inc**](https://epri-peac.com/solar-equipment/brands/first-solar-inc/) Registry: **CEC Verified Engineering Specification**

First Solar Inc FS-4107A-2 is a 107.5 W STC (99.7 W PTC) Thin Film solar module ranking #21,537 of 21,677 CEC listings (below all-CEC median; higher than 0.6% of peers). It delivers 14.93% efficiency, 86.6 V Voc at 25 C, and 94.72 V cold Voc at -10 C (6 panels max per 600 V string).

- **STC Wattage** : 107.5 W

- **PTC Wattage** : 99.7 W

- **Voc @ 25C** : 86.6 V

- **Efficiency** : 14.93%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does First Solar Inc FS-4107A-2 Compare Against Peer CEC Listings?

Engineering position of First Solar Inc FS-4107A-2 (107.5 W STC) vs. Caterpillar Inc PVT112 across 106 CEC Thin Film solar modules.

Built with 216 Thin Film cells, First Solar Inc FS-4107A-2 pairs strong 92.7% PTC-to-STC heat retention (#11,468 of 21,677) with 86.6 V nominal Voc. An 8 kW residential build (8,062 W DC, 7,478 W PTC) saves ~$2,017/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Caterpillar Inc PVT112 offers a 112.5 W alternative.

## Where Does First Solar Inc FS-4107A-2 Fall Across Listed CEC Models?

Plots First Solar Inc FS-4107A-2 at 107.5 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

## What Dataset Percentiles Define First Solar Inc FS-4107A-2?

Benchmarks First Solar Inc FS-4107A-2 on STC wattage, thermal PTC/STC retention, and 14.93 aperture conversion efficiency against CEC peers.

## What Do the Dataset Ranks Show for First Solar Inc FS-4107A-2?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for First Solar Inc FS-4107A-2 by First Solar Inc.

Rank #21,537 / 21,677

### 107.5 W STC · Higher Than 0.6%

107.5 W STC (-277.5 W vs all-CEC median) vs 117.5 W Thin Film median.

Eff #19,866

### 14.93% Aperture Efficiency

Power density 149.3 W/m2 (4.98 percentage points below 19.91% CEC median). PTC/STC ratio: 92.7% (rank #11,468).

NEC 690.7 Limit

### 6 Panels Max @ -10 C (600 V)

Cold Voc reaches 94.72 V at -10 C (568.3 V string) and 97.04 V at -20 C (6 max).

 8 kW Reference Array

### 75 Panels = 8,062 W STC

Occupies 54.0 m2 (581 sq ft) producing 7,478 W PTC; NEC 690.8 OCPD floor is 2.73 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 86.6 * (1 + (-0.268/100) * (-10 - 25)) = 94.72 V | OCPD = 1.56 * 1.75 = 2.73 A

Inputs from CEC Modules.csv for First Solar Inc FS-4107A-2: Voc=86.6 V, beta_Voc=-0.268%/C, Isc=1.75 A, STC=107.5 W, Area=0.72 m2.

**Result:** 6 panels max on 600 V (568.3 V); 75 panels for 8 kW (581 sq ft).

## What Are the Published CEC Specifications for First Solar Inc FS-4107A-2?

Laboratory test ratings recorded for First Solar Inc FS-4107A-2 (Thin Film) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for First Solar Inc FS-4107A-2.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 107.5 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 99.7 W (92.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 86.6 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 1.75 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 68.6 V / 1.57 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.268 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 14.93% (0.72 m2) | Array roof footprint density |
| **Cell Count & Technology** | 216 cells (Thin Film) | Monofacial backsheet |

## How Many First Solar Inc FS-4107A-2 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (581 sq ft at 8 kW), and estimated Year-1 electric bill offset for First Solar Inc FS-4107A-2.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 56 | 6.02 kW | 434 sq ft | $1,507 | $2,548 |
| **8 kW Class** | 75 | 8.06 kW | 581 sq ft | $2,017 | $3,411 |
| **10 kW Class** | 94 | 10.11 kW | 729 sq ft | $2,530 | $4,279 |

## How Many First Solar Inc FS-4107A-2 Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for First Solar Inc FS-4107A-2 (beta_Voc -0.268%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=86.6V and beta_Voc=-0.268%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 97.04 V | 6 panels | 582.2 V | 10 panels |
| **-10 C (14 F)** | 94.72 V | 6 panels | 568.3 V | 10 panels |
| **0 C (32 F)** | 92.4 V | 6 panels | 554.4 V | 10 panels |
| **25 C (77 F STC)** | 86.6 V | 6 panels | 519.6 V | 11 panels |

## Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-4107A-2?

Closest cross-brand CEC competitors to First Solar Inc FS-4107A-2 matched near 107.5 W STC and 86.6 V Voc, led by Caterpillar Inc PVT112.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Caterpillar Inc PVT112**](https://epri-peac.com/solar-equipment/modules/caterpillar-inc/caterpillar-inc-pvt112/) Caterpillar Inc | 112.5 W | +5.0 W | 87.7 V | 15.62% | 92.9% |
| [**Caterpillar Inc PVT112 ARC**](https://epri-peac.com/solar-equipment/modules/caterpillar-inc/caterpillar-inc-pvt112-arc/) Caterpillar Inc | 112.5 W | +5.0 W | 87.7 V | 15.62% | 92.9% |
| [**Toledo Solar Inc TS1**](https://epri-peac.com/solar-equipment/modules/toledo-solar-inc/toledo-solar-inc-ts1/) Toledo Solar Inc | 115.0 W | +7.5 W | 87.1 V | 15.97% | 92.9% |
| [**T-Solar Global TS102**](https://epri-peac.com/solar-equipment/modules/t-solar-global/t-solar-global-ts102/) T-Solar Global | 102.5 W | -5.0 W | 93.0 V | 7.19% | 93.0% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-4107A-2?

Evaluate First Solar Inc FS-4107A-2 (107.5 W STC, 86.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-4107A-2 reaches 97.04 V per panel—exceeding 6 panels in series voids 600 V inverter warranties.
- Footprint constraint: 75 panels for an 8 kW build require 581 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 75 panels (581 sq ft).
- 2026 tax credit baseline: cash residential installs of First Solar Inc FS-4107A-2 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### First Solar Inc FS-4107A-2 8 kW Residential Fit

Needs 75 modules (581 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 6 panels (-10 C) or 6 panels (-20 C), or compare Caterpillar Inc PVT112.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 99.7 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for First Solar Inc FS-4107A-2 by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for First Solar Inc FS-4107A-2?

Multiplying First Solar Inc FS-4107A-2's 1.75 A short-circuit current by 1.56 equals 2.73 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

### Can First Solar Inc FS-4107A-2 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 94.72 V cold Voc at 14 F and handles 1.75 A Isc; string inverters cap First Solar Inc FS-4107A-2 at 6 panels on 600 V.

### Is First Solar Inc FS-4107A-2 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of First Solar Inc FS-4107A-2 rely on utility bill offset (~$2,017/yr at 8 kW) rather than 25D.

## Related Pages

Compare First Solar Inc equipment, Caterpillar Inc PVT112 specs, utility payback rates, and NEC string calculators alongside First Solar Inc FS-4107A-2.

[All First Solar Inc Certified Solar Models](https://epri-peac.com/solar-equipment/brands/first-solar-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From First Solar Inc

- [All First Solar Inc Specs](https://epri-peac.com/solar-equipment/brands/first-solar-inc/)
- [First Solar Inc FS-7550A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7550a-ft1/)
- [First Solar Inc FS-7550A-TR1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7550a-tr1/)
- [First Solar Inc FS-7545A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7545a-ft1/)
- [First Solar Inc FS-7545A-TR1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7545a-tr1/)
- [First Solar Inc FS-7540A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7540a-ft1/)
