title: "First Solar Inc FS-4102A Specs (102.5W, 88.0V Voc)"
url: https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-4102a/
description: "CEC datasheet for First Solar Inc FS-4102A: 102.5W STC, 88.0V Voc, 79-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# First Solar Inc FS-4102A — CEC Solar Module Specifications

Manufacturer: [**First Solar Inc**](https://epri-peac.com/solar-equipment/brands/first-solar-inc/) Registry: **CEC Verified Engineering Specification**

First Solar Inc FS-4102A is a 102.5 W STC (96.9 W PTC) Thin Film solar module ranking #21,557 of 21,677 CEC listings (below all-CEC median; higher than 0.5% of peers). It delivers 14.24% efficiency, 88.0 V Voc at 25 C, and 96.1 V cold Voc at -10 C (6 panels max per 600 V string).

- **STC Wattage** : 102.5 W

- **PTC Wattage** : 96.9 W

- **Voc @ 25C** : 88.0 V

- **Efficiency** : 14.24%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does First Solar Inc FS-4102A Compare Against Peer CEC Listings?

Engineering position of First Solar Inc FS-4102A (102.5 W STC) vs. Caterpillar Inc PVT112 across 106 CEC Thin Film solar modules.

Ranking #21,557 across 21,677 CEC solar panels (below all-CEC median; higher than 0.5% of peers), First Solar Inc FS-4102A operates as a compact residential or specialty off-grid module sitting 15.0 W below the 117.5 W Thin Film median. Higher 88.0 V open-circuit voltage caps 600 V residential strings at 6 panels at 14 F (-10 C). With strong 94.5% PTC-to-STC heat retention (#2,573 of 21,677), 79 panels occupy 612 sq ft and offset roughly $2,027/yr at average US rates (or $3,428/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

## Where Does First Solar Inc FS-4102A Fall Across Listed CEC Models?

Plots First Solar Inc FS-4102A at 102.5 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

## What Dataset Percentiles Define First Solar Inc FS-4102A?

Benchmarks First Solar Inc FS-4102A on STC wattage, thermal PTC/STC retention, and 14.24 aperture conversion efficiency against CEC peers.

## What Do the Dataset Ranks Show for First Solar Inc FS-4102A?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for First Solar Inc FS-4102A by First Solar Inc.

Rank #21,557 / 21,677

### 102.5 W STC · Higher Than 0.5%

102.5 W STC (-282.5 W vs all-CEC median) vs 117.5 W Thin Film median.

Eff #20,657

### 14.24% Aperture Efficiency

Power density 142.4 W/m2 (5.67 percentage points below 19.91% CEC median). PTC/STC ratio: 94.5% (rank #2,573).

NEC 690.7 Limit

### 6 Panels Max @ -10 C (600 V)

Cold Voc reaches 96.1 V at -10 C (576.6 V string) and 98.41 V at -20 C (6 max).

 8 kW Reference Array

### 79 Panels = 8,098 W STC

Occupies 56.9 m2 (612 sq ft) producing 7,655 W PTC; NEC 690.8 OCPD floor is 2.45 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 88.0 * (1 + (-0.263/100) * (-10 - 25)) = 96.1 V | OCPD = 1.56 * 1.57 = 2.45 A

Inputs from CEC Modules.csv for First Solar Inc FS-4102A: Voc=88.0 V, beta_Voc=-0.263%/C, Isc=1.57 A, STC=102.5 W, Area=0.72 m2.

**Result:** 6 panels max on 600 V (576.6 V); 79 panels for 8 kW (612 sq ft).

## What Are the Published CEC Specifications for First Solar Inc FS-4102A?

Laboratory test ratings recorded for First Solar Inc FS-4102A (Thin Film) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for First Solar Inc FS-4102A.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 102.5 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 96.9 W (94.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 88.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 1.57 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 70.0 V / 1.47 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.263 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 14.24% (0.72 m2) | Array roof footprint density |
| **Cell Count & Technology** | 216 cells (Thin Film) | Monofacial backsheet |

## How Many First Solar Inc FS-4102A Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (612 sq ft at 8 kW), and estimated Year-1 electric bill offset for First Solar Inc FS-4102A.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 59 | 6.05 kW | 457 sq ft | $1,514 | $2,561 |
| **8 kW Class** | 79 | 8.1 kW | 612 sq ft | $2,027 | $3,428 |
| **10 kW Class** | 98 | 10.04 kW | 760 sq ft | $2,513 | $4,249 |

## How Many First Solar Inc FS-4102A Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for First Solar Inc FS-4102A (beta_Voc -0.263%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=88.0V and beta_Voc=-0.263%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 98.41 V | 6 panels | 590.5 V | 10 panels |
| **-10 C (14 F)** | 96.1 V | 6 panels | 576.6 V | 10 panels |
| **0 C (32 F)** | 93.79 V | 6 panels | 562.7 V | 10 panels |
| **25 C (77 F STC)** | 88.0 V | 6 panels | 528.0 V | 11 panels |

## Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-4102A?

Closest cross-brand CEC competitors to First Solar Inc FS-4102A matched near 102.5 W STC and 88.0 V Voc, led by Caterpillar Inc PVT112.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Caterpillar Inc PVT112**](https://epri-peac.com/solar-equipment/modules/caterpillar-inc/caterpillar-inc-pvt112/) Caterpillar Inc | 112.5 W | +10.0 W | 87.7 V | 15.62% | 92.9% |
| [**Caterpillar Inc PVT112 ARC**](https://epri-peac.com/solar-equipment/modules/caterpillar-inc/caterpillar-inc-pvt112-arc/) Caterpillar Inc | 112.5 W | +10.0 W | 87.7 V | 15.62% | 92.9% |
| [**Toledo Solar Inc TS1**](https://epri-peac.com/solar-equipment/modules/toledo-solar-inc/toledo-solar-inc-ts1/) Toledo Solar Inc | 115.0 W | +12.5 W | 87.1 V | 15.97% | 92.9% |
| [**T-Solar Global TS102**](https://epri-peac.com/solar-equipment/modules/t-solar-global/t-solar-global-ts102/) T-Solar Global | 102.5 W | Tie (0 W) | 93.0 V | 7.19% | 93.0% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-4102A?

Evaluate First Solar Inc FS-4102A (102.5 W STC, 88.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-4102A reaches 98.41 V per panel—exceeding 6 panels in series voids 600 V inverter warranties.
- Footprint constraint: 79 panels for an 8 kW build require 612 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 79 panels (612 sq ft).
- 2026 tax credit baseline: cash residential installs of First Solar Inc FS-4102A carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### First Solar Inc FS-4102A 8 kW Residential Fit

Needs 79 modules (612 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 6 panels (-10 C) or 6 panels (-20 C), or compare Caterpillar Inc PVT112.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 96.9 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for First Solar Inc FS-4102A by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

### How many First Solar Inc FS-4102A panels fit on a 600 V winter solar string?

At -10 C (14 F), First Solar Inc FS-4102A cold Voc rises from 88.0 V to 96.1 V (beta_Voc -0.263%/C), capping a 600 V string at 6 panels (576.6 V).

### How much roof area does an 8 kW array of First Solar Inc FS-4102A need?

An 8 kW DC system uses 79 First Solar Inc FS-4102A modules (8,098 W STC / 7,655 W PTC), covering roughly 612 sq ft and saving ~$2,027/yr at 18.54 c/kWh.

### How does First Solar Inc FS-4102A compare against Caterpillar Inc PVT112?

First Solar Inc FS-4102A outputs 102.5 W STC (88.0 V Voc, rank #21,557 of 21,677), while Caterpillar Inc PVT112 delivers 112.5 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare First Solar Inc equipment, Caterpillar Inc PVT112 specs, utility payback rates, and NEC string calculators alongside First Solar Inc FS-4102A.

[All First Solar Inc Certified Solar Models](https://epri-peac.com/solar-equipment/brands/first-solar-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From First Solar Inc

- [All First Solar Inc Specs](https://epri-peac.com/solar-equipment/brands/first-solar-inc/)
- [First Solar Inc FS-7550A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7550a-ft1/)
- [First Solar Inc FS-7550A-TR1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7550a-tr1/)
- [First Solar Inc FS-7545A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7545a-ft1/)
- [First Solar Inc FS-7545A-TR1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7545a-tr1/)
- [First Solar Inc FS-7540A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7540a-ft1/)