title: "First Solar Inc FS-385 Specs (85.0W, 61.0V Voc)"
url: https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-385/
description: "CEC datasheet for First Solar Inc FS-385: 85.0W STC, 61.0V Voc, 95-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# First Solar Inc FS-385 — CEC Solar Module Specifications

Manufacturer: [**First Solar Inc**](https://epri-peac.com/solar-equipment/brands/first-solar-inc/) Registry: **CEC Verified Engineering Specification**

First Solar Inc FS-385 is a 85.0 W STC (80.8 W PTC) Thin Film solar module ranking #21,602 of 21,677 CEC listings (below all-CEC median; higher than 0.3% of peers). It delivers 11.81% efficiency, 61.0 V Voc at 25 C, and 64.65 V cold Voc at -10 C (9 panels max per 600 V string).

- **STC Wattage** : 85.0 W

- **PTC Wattage** : 80.8 W

- **Voc @ 25C** : 61.0 V

- **Efficiency** : 11.81%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does First Solar Inc FS-385 Compare Against Peer CEC Listings?

Engineering position of First Solar Inc FS-385 (85.0 W STC) vs. Zhongshan Ruike New Energy Co Ltd RK-75-2 across 106 CEC Thin Film solar modules.

Ranking #21,602 across 21,677 CEC solar panels (below all-CEC median; higher than 0.3% of peers), First Solar Inc FS-385 operates as a compact residential or specialty off-grid module sitting 32.5 W below the 117.5 W Thin Film median. Higher 61.0 V open-circuit voltage caps 600 V residential strings at 9 panels at 14 F (-10 C). With strong 95.1% PTC-to-STC heat retention (#713 of 21,677), 95 panels occupy 736 sq ft and offset roughly $2,020/yr at average US rates (or $3,415/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

## Where Does First Solar Inc FS-385 Fall Across Listed CEC Models?

Plots First Solar Inc FS-385 at 85.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

## What Dataset Percentiles Define First Solar Inc FS-385?

Benchmarks First Solar Inc FS-385 on STC wattage, thermal PTC/STC retention, and 11.81 aperture conversion efficiency against CEC peers.

## What Do the Dataset Ranks Show for First Solar Inc FS-385?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for First Solar Inc FS-385 by First Solar Inc.

Rank #21,602 / 21,677

### 85.0 W STC · Higher Than 0.3%

85.0 W STC (-300.0 W vs all-CEC median) vs 117.5 W Thin Film median.

Eff #21,584

### 11.81% Aperture Efficiency

Power density 118.1 W/m2 (8.10 percentage points below 19.91% CEC median). PTC/STC ratio: 95.1% (rank #713).

NEC 690.7 Limit

### 9 Panels Max @ -10 C (600 V)

Cold Voc reaches 64.65 V at -10 C (581.9 V string) and 65.69 V at -20 C (9 max).

 8 kW Reference Array

### 95 Panels = 8,075 W STC

Occupies 68.4 m2 (736 sq ft) producing 7,676 W PTC; NEC 690.8 OCPD floor is 3.09 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 61.0 * (1 + (-0.171/100) * (-10 - 25)) = 64.65 V | OCPD = 1.56 * 1.98 = 3.09 A

Inputs from CEC Modules.csv for First Solar Inc FS-385: Voc=61.0 V, beta_Voc=-0.171%/C, Isc=1.98 A, STC=85.0 W, Area=0.72 m2.

**Result:** 9 panels max on 600 V (581.9 V); 95 panels for 8 kW (736 sq ft).

## What Are the Published CEC Specifications for First Solar Inc FS-385?

Laboratory test ratings recorded for First Solar Inc FS-385 (Thin Film) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for First Solar Inc FS-385.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 85.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 80.8 W (95.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 61.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 1.98 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 48.5 V / 1.76 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.171 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 11.81% (0.72 m2) | Array roof footprint density |
| **Cell Count & Technology** | 77 cells (Thin Film) | Monofacial backsheet |

## How Many First Solar Inc FS-385 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (736 sq ft at 8 kW), and estimated Year-1 electric bill offset for First Solar Inc FS-385.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 71 | 6.04 kW | 550 sq ft | $1,512 | $2,556 |
| **8 kW Class** | 95 | 8.07 kW | 736 sq ft | $2,020 | $3,415 |
| **10 kW Class** | 118 | 10.03 kW | 915 sq ft | $2,510 | $4,245 |

## Which Sibling Wattage & Trim Variants Belong to This First Solar Inc Series?

Sibling wattage bins and frame colors grouped with First Solar Inc FS-385 under First Solar Inc to prevent duplicate spec pages.

Sibling CEC listings grouped into the First Solar Inc FS-385 wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **First Solar Inc FS-375** | 75.0 W | 71.2 W | 61.6 V | 49.8 V | 10.42% |
| **First Solar Inc FS-377** | 77.0 W | 73.1 W | 61.7 V | 50.4 V | 10.69% |
| **First Solar Inc FS-380** | 80.0 W | 76.0 W | 61.7 V | 50.7 V | 11.11% |
| **First Solar Inc FS-382** | 82.5 W | 78.4 W | 62.0 V | 51.0 V | 11.46% |
| **First Solar Inc FS-385** | 85.0 W | 80.8 W | 61.0 V | 48.5 V | 11.81% |
| **First Solar Inc FS-387** | 87.5 W | 83.4 W | 61.0 V | 49.2 V | 12.15% |
| **First Solar Inc FS-390** | 90.0 W | 85.8 W | 61.0 V | 49.2 V | 12.5% |
| **First Solar Inc FS-392** | 92.5 W | 88.5 W | 61.0 V | 49.5 V | 12.85% |
| **First Solar Inc FS-395** | 95.0 W | 90.9 W | 60.5 V | 47.5 V | 13.19% |

## How Many First Solar Inc FS-385 Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for First Solar Inc FS-385 (beta_Voc -0.171%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=61.0V and beta_Voc=-0.171%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 65.69 V | 9 panels | 591.2 V | 15 panels |
| **-10 C (14 F)** | 64.65 V | 9 panels | 581.9 V | 15 panels |
| **0 C (32 F)** | 63.61 V | 9 panels | 572.5 V | 15 panels |
| **25 C (77 F STC)** | 61.0 V | 9 panels | 549.0 V | 16 panels |

## Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-385?

Closest cross-brand CEC competitors to First Solar Inc FS-385 matched near 85.0 W STC and 61.0 V Voc, led by Zhongshan Ruike New Energy Co Ltd RK-75-2.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Zhongshan Ruike New Energy Co Ltd RK-75-2**](https://epri-peac.com/solar-equipment/modules/zhongshan-ruike-new-energy-co-ltd/zhongshan-ruike-new-energy-co-ltd-rk-75-2/) Zhongshan Ruike New Energy Co Ltd | 75.0 W | -10.0 W | 58.5 V | 10.42% | 93.9% |
| [**Centrosolar America VS-140C1**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-vs-140c1/) Centrosolar America | 140.0 W | +55.0 W | 60.6 V | 12.89% | 92.7% |
| [**Miasole FLEX-03 120N**](https://epri-peac.com/solar-equipment/modules/miasole/miasole-flex-03-120n/) Miasole | 115.1 W | +30.1 W | 37.8 V | 12.82% | 90.9% |
| [**Centrosolar America VS-140C2**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-vs-140c2/) Centrosolar America | 140.0 W | +55.0 W | 79.95 V | 12.89% | 92.9% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-385?

Evaluate First Solar Inc FS-385 (85.0 W STC, 61.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-385 reaches 65.69 V per panel—exceeding 9 panels in series voids 600 V inverter warranties.
- Footprint constraint: 95 panels for an 8 kW build require 736 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 95 panels (736 sq ft).
- 2026 tax credit baseline: cash residential installs of First Solar Inc FS-385 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### First Solar Inc FS-385 8 kW Residential Fit

Needs 95 modules (736 sq ft) with a 15 A string OCPD, offsetting ~$2,020/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 9 panels (-10 C) or 9 panels (-20 C), or compare Zhongshan Ruike New Energy Co Ltd RK-75-2.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 80.8 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for First Solar Inc FS-385 by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

### How many First Solar Inc FS-385 panels fit on a 600 V winter solar string?

At -10 C (14 F), First Solar Inc FS-385 cold Voc rises from 61.0 V to 64.65 V (beta_Voc -0.171%/C), capping a 600 V string at 9 panels (581.9 V).

### How much roof area does an 8 kW array of First Solar Inc FS-385 need?

An 8 kW DC system uses 95 First Solar Inc FS-385 modules (8,075 W STC / 7,676 W PTC), covering roughly 736 sq ft and saving ~$2,020/yr at 18.54 c/kWh.

### How does First Solar Inc FS-385 compare against Zhongshan Ruike New Energy Co Ltd RK-75-2?

First Solar Inc FS-385 outputs 85.0 W STC (61.0 V Voc, rank #21,602 of 21,677), while Zhongshan Ruike New Energy Co Ltd RK-75-2 delivers 75.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare First Solar Inc equipment, Zhongshan Ruike New Energy Co Ltd RK-75-2 specs, utility payback rates, and NEC string calculators alongside First Solar Inc FS-385.

[All First Solar Inc Certified Solar Models](https://epri-peac.com/solar-equipment/brands/first-solar-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From First Solar Inc

- [All First Solar Inc Specs](https://epri-peac.com/solar-equipment/brands/first-solar-inc/)
- [First Solar Inc FS-7550A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7550a-ft1/)
- [First Solar Inc FS-7550A-TR1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7550a-tr1/)
- [First Solar Inc FS-7545A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7545a-ft1/)
- [First Solar Inc FS-7545A-TR1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7545a-tr1/)
- [First Solar Inc FS-7540A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7540a-ft1/)