title: "First Solar Inc FS-370 Specs (70.0W, 60.6V Voc)"
url: https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-370/
description: "CEC datasheet for First Solar Inc FS-370: 70.0W STC, 60.6V Voc, 115-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# First Solar Inc FS-370 — CEC Solar Module Specifications

Manufacturer: [**First Solar Inc**](https://epri-peac.com/solar-equipment/brands/first-solar-inc/) Registry: **CEC Verified Engineering Specification**

First Solar Inc FS-370 is a 70.0 W STC (66.4 W PTC) Thin Film solar module ranking #21,637 of 21,677 CEC listings (below all-CEC median; higher than 0.2% of peers). It delivers 9.72% efficiency, 60.6 V Voc at 25 C, and 64.23 V cold Voc at -10 C (9 panels max per 600 V string).

- **STC Wattage** : 70.0 W

- **PTC Wattage** : 66.4 W

- **Voc @ 25C** : 60.6 V

- **Efficiency** : 9.72%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does First Solar Inc FS-370 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for First Solar Inc FS-370 (Thin Film) residential solar systems.

Homeowners evaluating First Solar Inc FS-370 need 86 panels for 6 kW or 115 panels (891 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 115 panels (891 sq ft). Under NEC 690.7(A), beta_Voc (-0.171%/C) pushes open-circuit voltage to 64.23 V at 14 F and 65.26 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

## Where Does First Solar Inc FS-370 Fall Across Listed CEC Models?

Comparison of First Solar Inc FS-370 (70.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

## What Dataset Percentiles Define First Solar Inc FS-370?

Relative ranking of First Solar Inc FS-370 across nameplate watts, 94.9% PTC thermal ratio, and module aperture efficiency.

## What Do the Dataset Ranks Show for First Solar Inc FS-370?

Summary of First Solar Inc FS-370 output rank, 8 kW array size (115 panels), efficiency rating, and 600 V string limit.

Rank #21,637 / 21,677

### 70.0 W STC · Higher Than 0.2%

70.0 W STC (-315.0 W vs all-CEC median) vs 117.5 W Thin Film median.

Eff #21,636

### 9.72% Aperture Efficiency

Power density 97.2 W/m2 (10.19 percentage points below 19.91% CEC median). PTC/STC ratio: 94.9% (rank #1,466).

NEC 690.7 Limit

### 9 Panels Max @ -10 C (600 V)

Cold Voc reaches 64.23 V at -10 C (578.1 V string) and 65.26 V at -20 C (9 max).

 8 kW Reference Array

### 115 Panels = 8,050 W STC

Occupies 82.8 m2 (891 sq ft) producing 7,636 W PTC; NEC 690.8 OCPD floor is 2.71 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 60.6 * (1 + (-0.171/100) * (-10 - 25)) = 64.23 V | OCPD = 1.56 * 1.74 = 2.71 A

Inputs from CEC Modules.csv for First Solar Inc FS-370: Voc=60.6 V, beta_Voc=-0.171%/C, Isc=1.74 A, STC=70.0 W, Area=0.72 m2.

**Result:** 9 panels max on 600 V (578.1 V); 115 panels for 8 kW (891 sq ft).

## What Are the Published CEC Specifications for First Solar Inc FS-370?

Complete CEC test sheet for First Solar Inc FS-370 including Isc (1.74 A), Voc (60.6 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for First Solar Inc FS-370.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 70.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 66.4 W (94.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 60.6 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 1.74 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 48.1 V / 1.46 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.171 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 9.72% (0.72 m2) | Array roof footprint density |
| **Cell Count & Technology** | 77 cells (Thin Film) | Monofacial backsheet |

## How Many First Solar Inc FS-370 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using First Solar Inc FS-370.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 86 | 6.02 kW | 667 sq ft | $1,507 | $2,548 |
| **8 kW Class** | 115 | 8.05 kW | 891 sq ft | $2,015 | $3,407 |
| **10 kW Class** | 143 | 10.01 kW | 1,108 sq ft | $2,505 | $4,236 |

## Which Sibling Wattage & Trim Variants Belong to This First Solar Inc Series?

Related First Solar Inc power steps and black/silver trims consolidated into this First Solar Inc FS-370 series guide.

Sibling CEC listings grouped into the First Solar Inc FS-370 wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **First Solar Inc FS-367** | 67.5 W | 64.0 W | 60.5 V | 47.8 V | 9.38% |
| **First Solar Inc FS-370** | 70.0 W | 66.4 W | 60.6 V | 48.1 V | 9.72% |
| **First Solar Inc FS-372** | 72.5 W | 68.8 W | 61.4 V | 49.5 V | 10.07% |

## How Many First Solar Inc FS-370 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for First Solar Inc FS-370 (60.6 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=60.6V and beta_Voc=-0.171%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 65.26 V | 9 panels | 587.3 V | 15 panels |
| **-10 C (14 F)** | 64.23 V | 9 panels | 578.1 V | 15 panels |
| **0 C (32 F)** | 63.19 V | 9 panels | 568.7 V | 15 panels |
| **25 C (77 F STC)** | 60.6 V | 9 panels | 545.4 V | 16 panels |

## Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-370?

Four comparable CEC modules such as Zhongshan Ruike New Energy Co Ltd RK-75-2 (75.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Zhongshan Ruike New Energy Co Ltd RK-75-2**](https://epri-peac.com/solar-equipment/modules/zhongshan-ruike-new-energy-co-ltd/zhongshan-ruike-new-energy-co-ltd-rk-75-2/) Zhongshan Ruike New Energy Co Ltd | 75.0 W | +5.0 W | 58.5 V | 10.42% | 93.9% |
| [**Centrosolar America VS-140C1**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-vs-140c1/) Centrosolar America | 140.0 W | +70.0 W | 60.6 V | 12.89% | 92.7% |
| [**Miasole FLEX-03 120N**](https://epri-peac.com/solar-equipment/modules/miasole/miasole-flex-03-120n/) Miasole | 115.1 W | +45.1 W | 37.8 V | 12.82% | 90.9% |
| [**Centrosolar America VS-140C2**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-vs-140c2/) Centrosolar America | 140.0 W | +70.0 W | 79.95 V | 12.89% | 92.9% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-370?

Evaluate First Solar Inc FS-370 (70.0 W STC, 60.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-370 reaches 65.26 V per panel—exceeding 9 panels in series voids 600 V inverter warranties.
- Footprint constraint: 115 panels for an 8 kW build require 891 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 115 panels (891 sq ft).
- 2026 tax credit baseline: cash residential installs of First Solar Inc FS-370 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### First Solar Inc FS-370 8 kW Residential Fit

Needs 115 modules (891 sq ft) with a 15 A string OCPD, offsetting ~$2,015/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 9 panels (-10 C) or 9 panels (-20 C), or compare Zhongshan Ruike New Energy Co Ltd RK-75-2.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 66.4 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for First Solar Inc FS-370 by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is First Solar Inc FS-370 PTC wattage (66.4 W) lower than STC (70.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 66.4 W PTC (94.9% retention) across First Solar Inc FS-370's 0.72 m2 aperture.

### Who should skip First Solar Inc FS-370 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 115 First Solar Inc FS-370 panels (891 sq ft) leave unusable roof gaps vs. Zhongshan Ruike New Energy Co Ltd RK-75-2.

### What is the 1,000 V commercial string limit for First Solar Inc FS-370?

On 1,000 V commercial inverters at -10 C (64.23 V cold Voc), First Solar Inc FS-370 fits up to 15 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting First Solar Inc FS-370.

## Related Pages

Compare First Solar Inc equipment, Zhongshan Ruike New Energy Co Ltd RK-75-2 specs, utility payback rates, and NEC string calculators alongside First Solar Inc FS-370.

[All First Solar Inc Certified Solar Models](https://epri-peac.com/solar-equipment/brands/first-solar-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From First Solar Inc

- [All First Solar Inc Specs](https://epri-peac.com/solar-equipment/brands/first-solar-inc/)
- [First Solar Inc FS-7550A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7550a-ft1/)
- [First Solar Inc FS-7550A-TR1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7550a-tr1/)
- [First Solar Inc FS-7545A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7545a-ft1/)
- [First Solar Inc FS-7545A-TR1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7545a-tr1/)
- [First Solar Inc FS-7540A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7540a-ft1/)