title: "First Solar Inc FS-277 Specs (77.5W, 93.0V Voc)"
url: https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-277/
description: "CEC datasheet for First Solar Inc FS-277: 77.5W STC, 93.0V Voc, 104-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# First Solar Inc FS-277 — CEC Solar Module Specifications

Manufacturer: [**First Solar Inc**](https://epri-peac.com/solar-equipment/brands/first-solar-inc/) Registry: **CEC Verified Engineering Specification**

First Solar Inc FS-277 is a 77.5 W STC (74.6 W PTC) Thin Film solar module ranking #21,610 of 21,677 CEC listings (below all-CEC median; higher than 0.3% of peers). It delivers 10.76% efficiency, 93.0 V Voc at 25 C, and 100.75 V cold Voc at -10 C (5 panels max per 600 V string).

- **STC Wattage** : 77.5 W

- **PTC Wattage** : 74.6 W

- **Voc @ 25C** : 93.0 V

- **Efficiency** : 10.76%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does First Solar Inc FS-277 Compare Against Peer CEC Listings?

Engineering position of First Solar Inc FS-277 (77.5 W STC) vs. T-Solar Global TS97 across 106 CEC Thin Film solar modules.

Ranking #21,610 across 21,677 CEC solar panels (below all-CEC median; higher than 0.3% of peers), First Solar Inc FS-277 operates as a compact residential or specialty off-grid module sitting 40.0 W below the 117.5 W Thin Film median. Higher 93.0 V open-circuit voltage caps 600 V residential strings at 5 panels at 14 F (-10 C). With strong 96.3% PTC-to-STC heat retention (#14 of 21,677), 104 panels occupy 806 sq ft and offset roughly $2,017/yr at average US rates (or $3,411/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

## Where Does First Solar Inc FS-277 Fall Across Listed CEC Models?

Plots First Solar Inc FS-277 at 77.5 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

## What Dataset Percentiles Define First Solar Inc FS-277?

Benchmarks First Solar Inc FS-277 on STC wattage, thermal PTC/STC retention, and 10.76 aperture conversion efficiency against CEC peers.

## What Do the Dataset Ranks Show for First Solar Inc FS-277?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for First Solar Inc FS-277 by First Solar Inc.

Rank #21,610 / 21,677

### 77.5 W STC · Higher Than 0.3%

77.5 W STC (-307.5 W vs all-CEC median) vs 117.5 W Thin Film median.

Eff #21,603

### 10.76% Aperture Efficiency

Power density 107.6 W/m2 (9.15 percentage points below 19.91% CEC median). PTC/STC ratio: 96.3% (rank #14).

NEC 690.7 Limit

### 5 Panels Max @ -10 C (600 V)

Cold Voc reaches 100.75 V at -10 C (503.8 V string) and 102.96 V at -20 C (5 max).

 8 kW Reference Array

### 104 Panels = 8,060 W STC

Occupies 74.9 m2 (806 sq ft) producing 7,758 W PTC; NEC 690.8 OCPD floor is 1.89 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 93.0 * (1 + (-0.238/100) * (-10 - 25)) = 100.75 V | OCPD = 1.56 * 1.21 = 1.89 A

Inputs from CEC Modules.csv for First Solar Inc FS-277: Voc=93.0 V, beta_Voc=-0.238%/C, Isc=1.21 A, STC=77.5 W, Area=0.72 m2.

**Result:** 5 panels max on 600 V (503.8 V); 104 panels for 8 kW (806 sq ft).

## What Are the Published CEC Specifications for First Solar Inc FS-277?

Laboratory test ratings recorded for First Solar Inc FS-277 (Thin Film) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for First Solar Inc FS-277.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 77.5 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 74.6 W (96.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 93.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 1.21 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 70.9 V / 1.09 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.238 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 10.76% (0.72 m2) | Array roof footprint density |
| **Cell Count & Technology** | 116 cells (Thin Film) | Monofacial backsheet |

## How Many First Solar Inc FS-277 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (806 sq ft at 8 kW), and estimated Year-1 electric bill offset for First Solar Inc FS-277.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 78 | 6.04 kW | 605 sq ft | $1,512 | $2,556 |
| **8 kW Class** | 104 | 8.06 kW | 806 sq ft | $2,017 | $3,411 |
| **10 kW Class** | 130 | 10.07 kW | 1,008 sq ft | $2,520 | $4,262 |

## Which Sibling Wattage & Trim Variants Belong to This First Solar Inc Series?

Sibling wattage bins and frame colors grouped with First Solar Inc FS-277 under First Solar Inc to prevent duplicate spec pages.

Sibling CEC listings grouped into the First Solar Inc FS-277 wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **First Solar Inc FS-275** | 75.0 W | 72.2 W | 92.0 V | 69.4 V | 10.42% |
| **First Solar Inc FS-277** | 77.5 W | 74.6 W | 93.0 V | 70.9 V | 10.76% |
| **First Solar Inc FS-280** | 80.0 W | 76.9 W | 91.5 V | 71.2 V | 11.11% |

## How Many First Solar Inc FS-277 Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for First Solar Inc FS-277 (beta_Voc -0.238%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=93.0V and beta_Voc=-0.238%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 102.96 V | 5 panels | 514.8 V | 9 panels |
| **-10 C (14 F)** | 100.75 V | 5 panels | 503.8 V | 9 panels |
| **0 C (32 F)** | 98.53 V | 6 panels | 591.2 V | 10 panels |
| **25 C (77 F STC)** | 93.0 V | 6 panels | 558.0 V | 10 panels |

## Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-277?

Closest cross-brand CEC competitors to First Solar Inc FS-277 matched near 77.5 W STC and 93.0 V Voc, led by T-Solar Global TS97.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**T-Solar Global TS97**](https://epri-peac.com/solar-equipment/modules/t-solar-global/t-solar-global-ts97/) T-Solar Global | 97.5 W | +20.0 W | 93.0 V | 6.84% | 92.9% |
| [**T-Solar Global TS102**](https://epri-peac.com/solar-equipment/modules/t-solar-global/t-solar-global-ts102/) T-Solar Global | 102.5 W | +25.0 W | 93.0 V | 7.19% | 93.0% |
| [**Du Pont Apollo DA095-A2**](https://epri-peac.com/solar-equipment/modules/du-pont-apollo/du-pont-apollo-da095-a2/) Du Pont Apollo | 95.0 W | +17.5 W | 100.0 V | 6.17% | 90.8% |
| [**Applied Materials 1/4 Size Single Junction Version 10**](https://epri-peac.com/solar-equipment/modules/applied-materials/applied-materials-1-4-size-single-junction-version-10/) Applied Materials | 116.0 W | +38.5 W | 96.2 V | 8.11% | 93.0% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-277?

Evaluate First Solar Inc FS-277 (77.5 W STC, 93.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-277 reaches 102.96 V per panel—exceeding 5 panels in series voids 600 V inverter warranties.
- Footprint constraint: 104 panels for an 8 kW build require 806 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 104 panels (806 sq ft).
- 2026 tax credit baseline: cash residential installs of First Solar Inc FS-277 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### First Solar Inc FS-277 8 kW Residential Fit

Needs 104 modules (806 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 5 panels (-10 C) or 5 panels (-20 C), or compare T-Solar Global TS97.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 74.6 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for First Solar Inc FS-277 by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

### How many First Solar Inc FS-277 panels fit on a 600 V winter solar string?

At -10 C (14 F), First Solar Inc FS-277 cold Voc rises from 93.0 V to 100.75 V (beta_Voc -0.238%/C), capping a 600 V string at 5 panels (503.8 V).

### How much roof area does an 8 kW array of First Solar Inc FS-277 need?

An 8 kW DC system uses 104 First Solar Inc FS-277 modules (8,060 W STC / 7,758 W PTC), covering roughly 806 sq ft and saving ~$2,017/yr at 18.54 c/kWh.

### How does First Solar Inc FS-277 compare against T-Solar Global TS97?

First Solar Inc FS-277 outputs 77.5 W STC (93.0 V Voc, rank #21,610 of 21,677), while T-Solar Global TS97 delivers 97.5 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare First Solar Inc equipment, T-Solar Global TS97 specs, utility payback rates, and NEC string calculators alongside First Solar Inc FS-277.

[All First Solar Inc Certified Solar Models](https://epri-peac.com/solar-equipment/brands/first-solar-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From First Solar Inc

- [All First Solar Inc Specs](https://epri-peac.com/solar-equipment/brands/first-solar-inc/)
- [First Solar Inc FS-7550A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7550a-ft1/)
- [First Solar Inc FS-7550A-TR1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7550a-tr1/)
- [First Solar Inc FS-7545A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7545a-ft1/)
- [First Solar Inc FS-7545A-TR1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7545a-tr1/)
- [First Solar Inc FS-7540A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7540a-ft1/)