CEC PV Module

# First Solar Inc FS-270 — CEC Solar Module Specifications

Manufacturer: [**First Solar Inc**](https://epri-peac.com/solar-equipment/brands/first-solar-inc/) Registry: **CEC Verified Engineering Specification**

First Solar Inc FS-270 is a 70.0 W STC (67.2 W PTC) Thin Film solar module ranking #21,637 of 21,677 CEC listings (below all-CEC median; higher than 0.2% of peers). It delivers 9.72% efficiency, 89.0 V Voc at 25 C, and 96.85 V cold Voc at -10 C (6 panels max per 600 V string).

- **STC Wattage** : 70.0 W

- **PTC Wattage** : 67.2 W

- **Voc @ 25C** : 89.0 V

- **Efficiency** : 9.72%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does First Solar Inc FS-270 Compare Against Peer CEC Listings?

How First Solar Inc First Solar Inc FS-270 handles rooftop heat (67.2 W PTC), 8 kW sizing, and cold winter string voltage.

First Solar Inc builds the First Solar Inc FS-270 (Thin Film) as a compact residential or specialty off-grid module delivering 97.2 W/m2 (10.19 percentage points below 19.91% CEC median). Compared against T-Solar Global TS97 (97.5 W), this model holds strong 96.0% PTC-to-STC heat retention (#21 of 21,677). Higher 89.0 V open-circuit voltage caps 600 V residential strings at 6 panels at 14 F (-10 C), while NEC 690.8 sets a 1.86 A overcurrent floor served by a 15 A breaker.

## Where Does First Solar Inc FS-270 Fall Across Listed CEC Models?

Where First Solar Inc FS-270 (70.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define First Solar Inc FS-270?

Percentile placement of First Solar Inc FS-270 across power density (97.2 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for First Solar Inc FS-270?

Four critical engineering numbers homeowners and solar installers check first when reviewing First Solar Inc FS-270 specifications. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Rank #21,637 / 21,677

### 70.0 W STC · Higher Than 0.2%

70.0 W STC (-315.0 W vs all-CEC median) vs 117.5 W Thin Film median.

Eff #21,636

### 9.72% Aperture Efficiency

Power density 97.2 W/m2 (10.19 percentage points below 19.91% CEC median). PTC/STC ratio: 96.0% (rank #21).

NEC 690.7 Limit

### 6 Panels Max @ -10 C (600 V)

Cold Voc reaches 96.85 V at -10 C (581.1 V string) and 99.09 V at -20 C (6 max).

 8 kW Reference Array

### 115 Panels = 8,050 W STC

Occupies 82.8 m2 (891 sq ft) producing 7,728 W PTC; NEC 690.8 OCPD floor is 1.86 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 89.0 * (1 + (-0.252/100) * (-10 - 25)) = 96.85 V | OCPD = 1.56 * 1.19 = 1.86 A

Inputs from CEC Modules.csv for First Solar Inc FS-270: Voc=89.0 V, beta_Voc=-0.252%/C, Isc=1.19 A, STC=70.0 W, Area=0.72 m2.

**Result:** 6 panels max on 600 V (581.1 V); 115 panels for 8 kW (891 sq ft).

## What Are the Published CEC Specifications for First Solar Inc FS-270?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for First Solar Inc FS-270.

Official California Energy Commission (NREL SAM) test parameters for First Solar Inc FS-270.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 70.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 67.2 W (96.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 89.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 1.19 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 67.9 V / 1.07 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.252 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 9.72% (0.72 m2) | Array roof footprint density |
| **Cell Count & Technology** | 116 cells (Thin Film) | Monofacial backsheet |

## How Many First Solar Inc FS-270 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using First Solar Inc FS-270 (70.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 86 | 6.02 kW | 667 sq ft | $1,507 | $2,548 |
| **8 kW Class** | 115 | 8.05 kW | 891 sq ft | $2,015 | $3,407 |
| **10 kW Class** | 143 | 10.01 kW | 1,108 sq ft | $2,505 | $4,236 |

## Which Sibling Wattage & Trim Variants Belong to This First Solar Inc Series?

All closely matched First Solar Inc wattages and cosmetic trims sharing the First Solar Inc FS-270 architecture. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Sibling CEC listings grouped into the First Solar Inc FS-270 wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **First Solar Inc FS-267** | 67.5 W | 64.8 W | 87.0 V | 64.2 V | 9.38% |
| **First Solar Inc FS-270** | 70.0 W | 67.2 W | 89.0 V | 67.9 V | 9.72% |
| **First Solar Inc FS-272** | 72.5 W | 69.8 W | 90.0 V | 67.9 V | 10.07% |

## How Many First Solar Inc FS-270 Modules Fit in a Cold-Weather String?

Maximum series module counts for First Solar Inc FS-270 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=89.0V and beta_Voc=-0.252%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 99.09 V | 6 panels | 594.5 V | 10 panels |
| **-10 C (14 F)** | 96.85 V | 6 panels | 581.1 V | 10 panels |
| **0 C (32 F)** | 94.61 V | 6 panels | 567.7 V | 10 panels |
| **25 C (77 F STC)** | 89.0 V | 6 panels | 534.0 V | 11 panels |

## Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-270?

Alternative CEC solar modules from competing brands near First Solar Inc FS-270 (70.0 W), including T-Solar Global TS97.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**T-Solar Global TS97**](https://epri-peac.com/solar-equipment/modules/t-solar-global/t-solar-global-ts97/) T-Solar Global | 97.5 W | +27.5 W | 93.0 V | 6.84% | 92.9% |
| [**Caterpillar Inc PVT112**](https://epri-peac.com/solar-equipment/modules/caterpillar-inc/caterpillar-inc-pvt112/) Caterpillar Inc | 112.5 W | +42.5 W | 87.7 V | 15.62% | 92.9% |
| [**Caterpillar Inc PVT112 ARC**](https://epri-peac.com/solar-equipment/modules/caterpillar-inc/caterpillar-inc-pvt112-arc/) Caterpillar Inc | 112.5 W | +42.5 W | 87.7 V | 15.62% | 92.9% |
| [**T-Solar Global TS102**](https://epri-peac.com/solar-equipment/modules/t-solar-global/t-solar-global-ts102/) T-Solar Global | 102.5 W | +32.5 W | 93.0 V | 7.19% | 93.0% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-270?

Evaluate First Solar Inc FS-270 (70.0 W STC, 89.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-270 reaches 99.09 V per panel—exceeding 6 panels in series voids 600 V inverter warranties.
- Footprint constraint: 115 panels for an 8 kW build require 891 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 115 panels (891 sq ft).
- 2026 tax credit baseline: cash residential installs of First Solar Inc FS-270 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### First Solar Inc FS-270 8 kW Residential Fit

Needs 115 modules (891 sq ft) with a 15 A string OCPD, offsetting ~$2,015/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 6 panels (-10 C) or 6 panels (-20 C), or compare T-Solar Global TS97.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 67.2 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for First Solar Inc FS-270 by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for First Solar Inc FS-270?

Multiplying First Solar Inc FS-270's 1.19 A short-circuit current by 1.56 equals 1.86 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

### Can First Solar Inc FS-270 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 96.85 V cold Voc at 14 F and handles 1.19 A Isc; string inverters cap First Solar Inc FS-270 at 6 panels on 600 V.

### Is First Solar Inc FS-270 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of First Solar Inc FS-270 rely on utility bill offset (~$2,015/yr at 8 kW) rather than 25D.

## Related Pages

Compare First Solar Inc equipment, T-Solar Global TS97 specs, utility payback rates, and NEC string calculators alongside First Solar Inc FS-270.

[All First Solar Inc Certified Solar Models](https://epri-peac.com/solar-equipment/brands/first-solar-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From First Solar Inc

- [All First Solar Inc Specs](https://epri-peac.com/solar-equipment/brands/first-solar-inc/)
- [First Solar Inc FS-7550A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7550a-ft1/)
- [First Solar Inc FS-7550A-TR1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7550a-tr1/)
- [First Solar Inc FS-7545A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7545a-ft1/)
- [First Solar Inc FS-7545A-TR1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7545a-tr1/)
- [First Solar Inc FS-7540A-FT1](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-7540a-ft1/)