title: "ES Foundry Corp ES-DP8-H72-560 Specs (560.0W, 50.2V Voc)"
url: https://epri-peac.com/solar-equipment/modules/es-foundry-corp/es-foundry-corp-es-dp8-h72-560/
description: "CEC datasheet for ES Foundry Corp ES-DP8-H72-560: 560.0W STC, 50.2V Voc, 15-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# ES Foundry Corp ES-DP8-H72-560 — CEC Solar Module Specifications

Manufacturer: [**ES Foundry Corp**](https://epri-peac.com/solar-equipment/brands/es-foundry-corp/) Registry: **CEC Verified Engineering Specification**

ES Foundry Corp ES-DP8-H72-560 is a 560.0 W STC (525.8 W PTC) Mono-c-Si solar module ranking #2,404 of 21,677 CEC listings (top 11.8%; higher than 88.2% of peers). It delivers 21.88% efficiency, 50.2 V Voc at 25 C, and 54.61 V cold Voc at -10 C (10 panels max per 600 V string).

- **STC Wattage** : 560.0 W

- **PTC Wattage** : 525.8 W

- **Voc @ 25C** : 50.2 V

- **Efficiency** : 21.88%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does ES Foundry Corp ES-DP8-H72-560 Compare Against Peer CEC Listings?

How ES Foundry Corp ES Foundry Corp ES-DP8-H72-560 handles rooftop heat (525.8 W PTC), 8 kW sizing, and cold winter string voltage.

ES Foundry Corp builds the ES Foundry Corp ES-DP8-H72-560 (Mono-c-Si) as a large-format commercial and ground-mount module delivering 218.8 W/m2 (1.97 percentage points above 19.91% CEC median). Compared against Bila Solar Inc AA560US-6x24GG (560.0 W), this model holds strong 93.9% PTC-to-STC heat retention (#5,210 of 21,677). Higher 50.2 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C), while NEC 690.8 sets a 22.06 A overcurrent floor served by a 25 A breaker.

## Where Does ES Foundry Corp ES-DP8-H72-560 Fall Across Listed CEC Models?

Where ES Foundry Corp ES-DP8-H72-560 (560.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define ES Foundry Corp ES-DP8-H72-560?

Percentile placement of ES Foundry Corp ES-DP8-H72-560 across power density (218.8 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for ES Foundry Corp ES-DP8-H72-560?

Four critical engineering numbers homeowners and solar installers check first when reviewing ES Foundry Corp ES-DP8-H72-560 specifications. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Rank #2,404 / 21,677

### Top 11.8% STC Output

560.0 W STC (+175.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #3,395

### 21.88% Aperture Efficiency

Power density 218.8 W/m2 (1.97 percentage points above 19.91% CEC median). PTC/STC ratio: 93.9% (rank #5,210).

NEC 690.7 Limit

### 10 Panels Max @ -10 C (600 V)

Cold Voc reaches 54.61 V at -10 C (546.1 V string) and 55.87 V at -20 C (10 max).

 8 kW Reference Array

### 15 Panels = 8,400 W STC

Occupies 38.4 m2 (413 sq ft) producing 7,887 W PTC; NEC 690.8 OCPD floor is 22.06 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 50.2 * (1 + (-0.251/100) * (-10 - 25)) = 54.61 V | OCPD = 1.56 * 14.14 = 22.06 A

Inputs from CEC Modules.csv for ES Foundry Corp ES-DP8-H72-560: Voc=50.2 V, beta_Voc=-0.251%/C, Isc=14.14 A, STC=560.0 W, Area=2.56 m2.

**Result:** 10 panels max on 600 V (546.1 V); 15 panels for 8 kW (413 sq ft).

## What Are the Published CEC Specifications for ES Foundry Corp ES-DP8-H72-560?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for ES Foundry Corp ES-DP8-H72-560.

Official California Energy Commission (NREL SAM) test parameters for ES Foundry Corp ES-DP8-H72-560.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 560.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 525.8 W (93.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 50.2 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 14.14 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 42.28 V / 13.25 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.251 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 21.88% (2.56 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Bifacial glass-glass |

## How Many ES Foundry Corp ES-DP8-H72-560 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using ES Foundry Corp ES-DP8-H72-560 (560.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 11 | 6.16 kW | 303 sq ft | $1,542 | $2,607 |
| **8 kW Class** | 15 | 8.4 kW | 413 sq ft | $2,102 | $3,555 |
| **10 kW Class** | 18 | 10.08 kW | 496 sq ft | $2,523 | $4,266 |

## Which Sibling Wattage & Trim Variants Belong to This ES Foundry Corp Series?

All closely matched ES Foundry Corp wattages and cosmetic trims sharing the ES Foundry Corp ES-DP8-H72-560 architecture. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Sibling CEC listings grouped into the ES Foundry Corp ES-DP8-H72-560 wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **ES Foundry Corp ES-DP8-H72-550** | 550.0 W | 516.2 W | 49.9 V | 41.96 V | 21.48% |
| **ES Foundry Corp ES-DP8-H72-555** | 555.0 W | 521.0 W | 50.05 V | 42.12 V | 21.68% |
| **ES Foundry Corp ES-DP8-H72-560** | 560.0 W | 525.8 W | 50.2 V | 42.28 V | 21.88% |
| **ES Foundry Corp ES-DP8-H72-565** | 565.0 W | 530.7 W | 50.33 V | 42.42 V | 22.07% |

## How Many ES Foundry Corp ES-DP8-H72-560 Modules Fit in a Cold-Weather String?

Maximum series module counts for ES Foundry Corp ES-DP8-H72-560 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=50.2V and beta_Voc=-0.251%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 55.87 V | 10 panels | 558.7 V | 17 panels |
| **-10 C (14 F)** | 54.61 V | 10 panels | 546.1 V | 18 panels |
| **0 C (32 F)** | 53.35 V | 11 panels | 586.9 V | 18 panels |
| **25 C (77 F STC)** | 50.2 V | 11 panels | 552.2 V | 19 panels |

## Which Cross-Brand Solar Modules Compare Closest to ES Foundry Corp ES-DP8-H72-560?

Alternative CEC solar modules from competing brands near ES Foundry Corp ES-DP8-H72-560 (560.0 W), including Bila Solar Inc AA560US-6x24GG.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Bila Solar Inc AA560US-6x24GG**](https://epri-peac.com/solar-equipment/modules/bila-solar-inc/bila-solar-inc-aa560us-6x24gg/) Bila Solar Inc | 560.0 W | Tie (0 W) | 50.2 V | 22.31% | 92.9% |
| [**Gautam Solar Pvt Ltd G2G1680-HAD**](https://epri-peac.com/solar-equipment/modules/gautam-solar-pvt-ltd/gautam-solar-pvt-ltd-g2g1680-had/) Gautam Solar Pvt Ltd | 560.0 W | Tie (0 W) | 50.44 V | 21.81% | 95.1% |
| [**Gautam Solar Pvt Ltd G2X1680N-UHAD**](https://epri-peac.com/solar-equipment/modules/gautam-solar-pvt-ltd/gautam-solar-pvt-ltd-g2x1680n-uhad/) Gautam Solar Pvt Ltd | 560.0 W | Tie (0 W) | 50.44 V | 21.79% | 94.8% |
| [**Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-560**](https://epri-peac.com/solar-equipment/modules/chint-new-energy-technology-co-ltd/chint-new-energy-technology-co-ltd-chsm72n-dg-f-bh-560/) Chint New Energy Technology Co Ltd | 560.0 W | Tie (0 W) | 50.5 V | 21.71% | 94.6% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for ES Foundry Corp ES-DP8-H72-560?

Evaluate ES Foundry Corp ES-DP8-H72-560 (560.0 W STC, 50.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), ES Foundry Corp ES-DP8-H72-560 reaches 55.87 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 15 panels for an 8 kW build require 413 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of ES Foundry Corp ES-DP8-H72-560 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### ES Foundry Corp ES-DP8-H72-560 8 kW Residential Fit

Needs 15 modules (413 sq ft) with a 25 A string OCPD, offsetting ~$2,102/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Bila Solar Inc AA560US-6x24GG.

### Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 525.8 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for ES Foundry Corp ES-DP8-H72-560 by ES Foundry Corp grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for ES Foundry Corp ES-DP8-H72-560?

Multiplying ES Foundry Corp ES-DP8-H72-560's 14.14 A short-circuit current by 1.56 equals 22.06 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

### Can ES Foundry Corp ES-DP8-H72-560 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 54.61 V cold Voc at 14 F and handles 14.14 A Isc; string inverters cap ES Foundry Corp ES-DP8-H72-560 at 10 panels on 600 V.

### Is ES Foundry Corp ES-DP8-H72-560 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of ES Foundry Corp ES-DP8-H72-560 rely on utility bill offset (~$2,102/yr at 8 kW) rather than 25D.

## Related Pages

Compare ES Foundry Corp equipment, Bila Solar Inc AA560US-6x24GG specs, utility payback rates, and NEC string calculators alongside ES Foundry Corp ES-DP8-H72-560.

[All ES Foundry Corp Certified Solar Models](https://epri-peac.com/solar-equipment/brands/es-foundry-corp/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From ES Foundry Corp

- [All ES Foundry Corp Specs](https://epri-peac.com/solar-equipment/brands/es-foundry-corp/)
- [ES Foundry Corp ES-DP8-H72L-560W](https://epri-peac.com/solar-equipment/modules/es-foundry-corp/es-foundry-corp-es-dp8-h72l-560w/)
- [ES Foundry Corp ES-DP8-H72-535](https://epri-peac.com/solar-equipment/modules/es-foundry-corp/es-foundry-corp-es-dp8-h72-535/)
- [ES Foundry Corp ES-DP8-H72L-535W](https://epri-peac.com/solar-equipment/modules/es-foundry-corp/es-foundry-corp-es-dp8-h72l-535w/)
- [ES Foundry Corp ES-DP8-H72L-520W](https://epri-peac.com/solar-equipment/modules/es-foundry-corp/es-foundry-corp-es-dp8-h72l-520w/)
- [ES Foundry Corp ES-DN8-H54B-450](https://epri-peac.com/solar-equipment/modules/es-foundry-corp/es-foundry-corp-es-dn8-h54b-450/)