title: "Eoplly New Energy Technology Specs #3 | WireAndSun"
url: https://epri-peac.com/solar-equipment/modules/eoplly-new-energy-technology/eoplly-new-energy-technology-ep156mb-60-240s-ac/
description: "CEC datasheet for Eoplly New Energy Technology EP156MB/60-240S AC: 240.0W STC, 36.9V Voc, 34-panel 8kW sizing, and NEC 690.7 limits."
---

CEC PV Module

# Eoplly New Energy Technology EP156MB/60-240S AC — CEC Solar Module Specifications

Manufacturer: [**Eoplly New Energy Technology**](https://epri-peac.com/solar-equipment/brands/eoplly-new-energy-technology/) Registry: **CEC Verified Engineering Specification**

Eoplly New Energy Technology EP156MB/60-240S AC is a 240.0 W STC (214.7 W PTC) Mono-c-Si solar module ranking #20,160 of 21,677 CEC listings (below all-CEC median; higher than 6.1% of peers). It delivers 14.83% efficiency, 36.9 V Voc at 25 C, and 41.42 V cold Voc at -10 C (14 panels max per 600 V string).

- **STC Wattage** : 240.0 W

- **PTC Wattage** : 214.7 W

- **Voc @ 25C** : 36.9 V

- **Efficiency** : 14.83%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Eoplly New Energy Technology EP156MB/60-240S AC Compare Against Peer CEC Listings?

Solar engineering breakdown for Eoplly New Energy Technology EP156MB/60-240S AC: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 240.0 W STC and 214.7 W PTC, Eoplly New Energy Technology EP156MB/60-240S AC sits -145.0 W vs all-CEC median (below all-CEC median; higher than 6.1% of peers) among 21,677 listed modules. Power density reaches 148.3 W/m2 (5.08 percentage points below 19.91% CEC median). Lower 36.9 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, whereas 1,000 V commercial inverters handle up to 24 panels in series. Alternative peer Centrosolar America DM60 240 rates 240.0 W.

## Where Does Eoplly New Energy Technology EP156MB/60-240S AC Fall Across Listed CEC Models?

Distribution marker showing Eoplly New Energy Technology EP156MB/60-240S AC (240.0 W) relative to the 385.0 W all-CEC solar panel median.

## What Dataset Percentiles Define Eoplly New Energy Technology EP156MB/60-240S AC?

Dataset percentiles tracking Eoplly New Energy Technology EP156MB/60-240S AC power output, thermal retention ratio, and aperture efficiency against 21,677 models.

## What Do the Dataset Ranks Show for Eoplly New Energy Technology EP156MB/60-240S AC?

Benchmark highlights for Eoplly New Energy Technology EP156MB/60-240S AC covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #20,160 / 21,677

### 240.0 W STC · Higher Than 6.1%

240.0 W STC (-145.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #19,987

### 14.83% Aperture Efficiency

Power density 148.3 W/m2 (5.08 percentage points below 19.91% CEC median). PTC/STC ratio: 89.5% (rank #19,939).

NEC 690.7 Limit

### 14 Panels Max @ -10 C (600 V)

Cold Voc reaches 41.42 V at -10 C (579.9 V string) and 42.71 V at -20 C (14 max).

 8 kW Reference Array

### 34 Panels = 8,160 W STC

Occupies 55.0 m2 (592 sq ft) producing 7,300 W PTC; NEC 690.8 OCPD floor is 13.54 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 36.9 * (1 + (-0.35/100) * (-10 - 25)) = 41.42 V | OCPD = 1.56 * 8.68 = 13.54 A

Inputs from CEC Modules.csv for Eoplly New Energy Technology EP156MB/60-240S AC: Voc=36.9 V, beta_Voc=-0.35%/C, Isc=8.68 A, STC=240.0 W, Area=1.618 m2.

**Result:** 14 panels max on 600 V (579.9 V); 34 panels for 8 kW (592 sq ft).

## What Are the Published CEC Specifications for Eoplly New Energy Technology EP156MB/60-240S AC?

Official CEC datasheet figures for Eoplly New Energy Technology EP156MB/60-240S AC (Mono-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for Eoplly New Energy Technology EP156MB/60-240S AC.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 240.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 214.7 W (89.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 36.9 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.68 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 30.01 V / 8.01 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.35 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 14.83% (1.618 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Eoplly New Energy Technology EP156MB/60-240S AC Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Eoplly New Energy Technology EP156MB/60-240S AC modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 25 | 6.0 kW | 435 sq ft | $1,502 | $2,539 |
| **8 kW Class** | 34 | 8.16 kW | 592 sq ft | $2,042 | $3,454 |
| **10 kW Class** | 42 | 10.08 kW | 731 sq ft | $2,523 | $4,266 |

## Which Sibling Wattage & Trim Variants Belong to This Eoplly New Energy Technology Series?

Consolidated Eoplly New Energy Technology wattage variants sharing the Eoplly New Energy Technology EP156MB/60-240S AC mechanical and cell layout.

Sibling CEC listings grouped into the Eoplly New Energy Technology EP156MB/60-240S AC wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Eoplly New Energy Technology EP156MB/60-230S AC** | 230.0 W | 205.5 W | 36.55 V | 29.24 V | 14.21% |
| **Eoplly New Energy Technology EP156MB/60-235S AC** | 235.0 W | 210.1 W | 36.72 V | 29.6 V | 14.52% |
| **Eoplly New Energy Technology EP156MB/60-240S AC** | 240.0 W | 214.7 W | 36.9 V | 30.01 V | 14.83% |
| **Eoplly New Energy Technology EP156MB/60-245S AC** | 245.0 W | 219.3 W | 37.08 V | 30.42 V | 15.14% |

## How Many Eoplly New Energy Technology EP156MB/60-240S AC Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Eoplly New Energy Technology EP156MB/60-240S AC (41.42 V at 14 F).

Computed from Voc=36.9V and beta_Voc=-0.35%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 42.71 V | 14 panels | 597.9 V | 23 panels |
| **-10 C (14 F)** | 41.42 V | 14 panels | 579.9 V | 24 panels |
| **0 C (32 F)** | 40.13 V | 14 panels | 561.8 V | 24 panels |
| **25 C (77 F STC)** | 36.9 V | 16 panels | 590.4 V | 27 panels |

## Which Cross-Brand Solar Modules Compare Closest to Eoplly New Energy Technology EP156MB/60-240S AC?

Competing CEC solar panels closest to Eoplly New Energy Technology EP156MB/60-240S AC in nameplate wattage and Voc, starting with Centrosolar America DM60 240.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Centrosolar America DM60 240**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-dm60-240/) Centrosolar America | 240.0 W | Tie (0 W) | 36.8 V | 14.64% | 90.6% |
| [**Heliene 60M240**](https://epri-peac.com/solar-equipment/modules/heliene/heliene-60m240/) Heliene | 240.0 W | Tie (0 W) | 36.8 V | 14.43% | 90.1% |
| [**Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-0-240T**](https://epri-peac.com/solar-equipment/modules/hanwha-qcells-qidong-co-ltd/hanwha-qcells-qidong-co-ltd-hsl60p6-pa-0-240t/) Hanwha Qcells (Qidong) Co Ltd | 240.0 W | Tie (0 W) | 37.1 V | 14.53% | 88.9% |
| [**Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-0-240TB**](https://epri-peac.com/solar-equipment/modules/hanwha-qcells-qidong-co-ltd/hanwha-qcells-qidong-co-ltd-hsl60p6-pa-0-240tb/) Hanwha Qcells (Qidong) Co Ltd | 240.0 W | Tie (0 W) | 37.1 V | 14.53% | 90.0% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Eoplly New Energy Technology EP156MB/60-240S AC?

Evaluate Eoplly New Energy Technology EP156MB/60-240S AC (240.0 W STC, 36.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Eoplly New Energy Technology EP156MB/60-240S AC reaches 42.71 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 34 panels for an 8 kW build require 592 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 34 panels (592 sq ft).
- 2026 tax credit baseline: cash residential installs of Eoplly New Energy Technology EP156MB/60-240S AC carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Eoplly New Energy Technology EP156MB/60-240S AC 8 kW Residential Fit

Needs 34 modules (592 sq ft) with a 15 A string OCPD, offsetting ~$2,042/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Centrosolar America DM60 240.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 214.7 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Eoplly New Energy Technology EP156MB/60-240S AC by Eoplly New Energy Technology grounded in CEC test data and NEC 690.7/690.8 limits.

### How many Eoplly New Energy Technology EP156MB/60-240S AC panels fit on a 600 V winter solar string?

At -10 C (14 F), Eoplly New Energy Technology EP156MB/60-240S AC cold Voc rises from 36.9 V to 41.42 V (beta_Voc -0.35%/C), capping a 600 V string at 14 panels (579.9 V).

### How much roof area does an 8 kW array of Eoplly New Energy Technology EP156MB/60-240S AC need?

An 8 kW DC system uses 34 Eoplly New Energy Technology EP156MB/60-240S AC modules (8,160 W STC / 7,300 W PTC), covering roughly 592 sq ft and saving ~$2,042/yr at 18.54 c/kWh.

### How does Eoplly New Energy Technology EP156MB/60-240S AC compare against Centrosolar America DM60 240?

Eoplly New Energy Technology EP156MB/60-240S AC outputs 240.0 W STC (36.9 V Voc, rank #20,160 of 21,677), while Centrosolar America DM60 240 delivers 240.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare Eoplly New Energy Technology equipment, Centrosolar America DM60 240 specs, utility payback rates, and NEC string calculators alongside Eoplly New Energy Technology EP156MB/60-240S AC.

[All Eoplly New Energy Technology Certified Solar Models](https://epri-peac.com/solar-equipment/brands/eoplly-new-energy-technology/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Eoplly New Energy Technology

- [All Eoplly New Energy Technology Specs](https://epri-peac.com/solar-equipment/brands/eoplly-new-energy-technology/)
- [Eoplly New Energy Technology EP156M/60-255 AC](https://epri-peac.com/solar-equipment/modules/eoplly-new-energy-technology/eoplly-new-energy-technology-ep156m-60-255-ac/)
- [Eoplly New Energy Technology EP156M/60-255S AC](https://epri-peac.com/solar-equipment/modules/eoplly-new-energy-technology/eoplly-new-energy-technology-ep156m-60-255s-ac/)
- [Eoplly New Energy Technology EP156P/60-255S AC](https://epri-peac.com/solar-equipment/modules/eoplly-new-energy-technology/eoplly-new-energy-technology-ep156p-60-255s-ac/)
- [Eoplly New Energy Technology EP156MB/60-250S AC](https://epri-peac.com/solar-equipment/modules/eoplly-new-energy-technology/eoplly-new-energy-technology-ep156mb-60-250s-ac/)
- [Eoplly New Energy Technology EP156MB/60-245 AC](https://epri-peac.com/solar-equipment/modules/eoplly-new-energy-technology/eoplly-new-energy-technology-ep156mb-60-245-ac/)