---
title: "Enphase Energy Inc Specs (300.0W, 40.1V Voc)"
url: https://epri-peac.com/solar-equipment/modules/enphase-energy-inc/enphase-energy-inc-xacm-iq7-lr6-60pb-300m/
description: "CEC datasheet for Enphase Energy Inc XACM-IQ7-LR6-60PB-300M: 300.0W STC, 40.1V Voc, 27-panel 8kW sizing, and NEC 690.7 limits."
---

CEC PV Module

# Enphase Energy Inc XACM-IQ7-LR6-60PB-300M — CEC Solar Module Specifications

Manufacturer: [**Enphase Energy Inc**](https://epri-peac.com/solar-equipment/brands/enphase-energy-inc/) Registry: **CEC Verified Engineering Specification**

Enphase Energy Inc XACM-IQ7-LR6-60PB-300M is a 300.0 W STC (273.2 W PTC) Mono-c-Si solar module ranking #16,498 of 21,677 CEC listings (below all-CEC median; higher than 22.1% of peers). It delivers 18.99% efficiency, 40.1 V Voc at 25 C, and 44.09 V cold Voc at -10 C (13 panels max per 600 V string).

- **STC Wattage** : 300.0 W

- **PTC Wattage** : 273.2 W

- **Voc @ 25C** : 40.1 V

- **Efficiency** : 18.99%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Enphase Energy Inc XACM-IQ7-LR6-60PB-300M Compare Against Peer CEC Listings?

How Enphase Energy Inc Enphase Energy Inc XACM-IQ7-LR6-60PB-300M handles rooftop heat (273.2 W PTC), 8 kW sizing, and cold winter string voltage.

Enphase Energy Inc builds the Enphase Energy Inc XACM-IQ7-LR6-60PB-300M (Mono-c-Si) as a compact residential or specialty off-grid module delivering 189.9 W/m2 (0.92 percentage points below 19.91% CEC median). Compared against CertainTeed CT300M10-03 (300.0 W), this model holds typical 91.1% PTC-to-STC thermal output (273.2 W real-world rating). Mid-range 40.1 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F, while NEC 690.8 sets a 15.3 A overcurrent floor served by a 20 A breaker.

## Where Does Enphase Energy Inc XACM-IQ7-LR6-60PB-300M Fall Across Listed CEC Models?

Where Enphase Energy Inc XACM-IQ7-LR6-60PB-300M (300.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Enphase Energy Inc XACM-IQ7-LR6-60PB-300M?

Percentile placement of Enphase Energy Inc XACM-IQ7-LR6-60PB-300M across power density (189.9 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for Enphase Energy Inc XACM-IQ7-LR6-60PB-300M?

Four critical engineering numbers homeowners and solar installers check first when reviewing Enphase Energy Inc XACM-IQ7-LR6-60PB-300M specifications. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Rank #16,498 / 21,677

### 300.0 W STC · Higher Than 22.1%

300.0 W STC (-85.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #13,479

### 18.99% Aperture Efficiency

Power density 189.9 W/m2 (0.92 percentage points below 19.91% CEC median). PTC/STC ratio: 91.1% (rank #16,462).

NEC 690.7 Limit

### 13 Panels Max @ -10 C (600 V)

Cold Voc reaches 44.09 V at -10 C (573.2 V string) and 45.22 V at -20 C (13 max).

 8 kW Reference Array

### 27 Panels = 8,100 W STC

Occupies 42.7 m2 (459 sq ft) producing 7,376 W PTC; NEC 690.8 OCPD floor is 15.3 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 40.1 * (1 + (-0.284/100) * (-10 - 25)) = 44.09 V | OCPD = 1.56 * 9.81 = 15.3 A

Inputs from CEC Modules.csv for Enphase Energy Inc XACM-IQ7-LR6-60PB-300M: Voc=40.1 V, beta_Voc=-0.284%/C, Isc=9.81 A, STC=300.0 W, Area=1.58 m2.

**Result:** 13 panels max on 600 V (573.2 V); 27 panels for 8 kW (459 sq ft).

## What Are the Published CEC Specifications for Enphase Energy Inc XACM-IQ7-LR6-60PB-300M?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Enphase Energy Inc XACM-IQ7-LR6-60PB-300M.

Official California Energy Commission (NREL SAM) test parameters for Enphase Energy Inc XACM-IQ7-LR6-60PB-300M.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 300.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 273.2 W (91.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 40.1 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 9.81 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 32.8 V / 9.15 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.284 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 18.99% (1.58 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Enphase Energy Inc XACM-IQ7-LR6-60PB-300M Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Enphase Energy Inc XACM-IQ7-LR6-60PB-300M (300.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 20 | 6.0 kW | 340 sq ft | $1,502 | $2,539 |
| **8 kW Class** | 27 | 8.1 kW | 459 sq ft | $2,027 | $3,428 |
| **10 kW Class** | 34 | 10.2 kW | 578 sq ft | $2,553 | $4,317 |

## Which Sibling Wattage & Trim Variants Belong to This Enphase Energy Inc Series?

All closely matched Enphase Energy Inc wattages and cosmetic trims sharing the Enphase Energy Inc XACM-IQ7-LR6-60PB-300M architecture. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Sibling CEC listings grouped into the Enphase Energy Inc XACM-IQ7-LR6-60PB-300M wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Enphase Energy Inc XACM-IQ7-LR6-60PB-300M** | 300.0 W | 273.2 W | 40.1 V | 32.8 V | 18.99% |
| **Enphase Energy Inc XACM-IQ7-LR6-60PB-305M** | 305.0 W | 278.9 W | 40.2 V | 33.0 V | 19.3% |

## How Many Enphase Energy Inc XACM-IQ7-LR6-60PB-300M Modules Fit in a Cold-Weather String?

Maximum series module counts for Enphase Energy Inc XACM-IQ7-LR6-60PB-300M from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=40.1V and beta_Voc=-0.284%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 45.22 V | 13 panels | 587.9 V | 22 panels |
| **-10 C (14 F)** | 44.09 V | 13 panels | 573.2 V | 22 panels |
| **0 C (32 F)** | 42.95 V | 13 panels | 558.4 V | 23 panels |
| **25 C (77 F STC)** | 40.1 V | 14 panels | 561.4 V | 24 panels |

## Which Cross-Brand Solar Modules Compare Closest to Enphase Energy Inc XACM-IQ7-LR6-60PB-300M?

Alternative CEC solar modules from competing brands near Enphase Energy Inc XACM-IQ7-LR6-60PB-300M (300.0 W), including CertainTeed CT300M10-03. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**CertainTeed CT300M10-03**](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-ct300m10-03/) CertainTeed | 300.0 W | Tie (0 W) | 40.3 V | 18.55% | 92.4% |
| [**CertainTeed CT300M11-03**](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-ct300m11-03/) CertainTeed | 300.0 W | Tie (0 W) | 40.3 V | 18.68% | 92.1% |
| [**FreeVolt PV-GRAF-60M6-300/M**](https://epri-peac.com/solar-equipment/modules/freevolt/freevolt-pv-graf-60m6-300-m/) FreeVolt | 300.0 W | Tie (0 W) | 39.6 V | 18.29% | 91.1% |
| [**CertainTeed CT300M10-01**](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-ct300m10-01/) CertainTeed | 300.0 W | Tie (0 W) | 39.1 V | 18.33% | 91.0% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Enphase Energy Inc XACM-IQ7-LR6-60PB-300M?

Evaluate Enphase Energy Inc XACM-IQ7-LR6-60PB-300M (300.0 W STC, 40.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Enphase Energy Inc XACM-IQ7-LR6-60PB-300M reaches 45.22 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 27 panels for an 8 kW build require 459 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 27 panels (459 sq ft).
- 2026 tax credit baseline: cash residential installs of Enphase Energy Inc XACM-IQ7-LR6-60PB-300M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Enphase Energy Inc XACM-IQ7-LR6-60PB-300M 8 kW Residential Fit

Needs 27 modules (459 sq ft) with a 20 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare CertainTeed CT300M10-03.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 273.2 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Enphase Energy Inc XACM-IQ7-LR6-60PB-300M by Enphase Energy Inc grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Enphase Energy Inc XACM-IQ7-LR6-60PB-300M?

Multiplying Enphase Energy Inc XACM-IQ7-LR6-60PB-300M's 9.81 A short-circuit current by 1.56 equals 15.3 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

### Can Enphase Energy Inc XACM-IQ7-LR6-60PB-300M pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 44.09 V cold Voc at 14 F and handles 9.81 A Isc; string inverters cap Enphase Energy Inc XACM-IQ7-LR6-60PB-300M at 13 panels on 600 V.

### Is Enphase Energy Inc XACM-IQ7-LR6-60PB-300M eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Enphase Energy Inc XACM-IQ7-LR6-60PB-300M rely on utility bill offset (~$2,027/yr at 8 kW) rather than 25D.

## Related Pages

Compare Enphase Energy Inc equipment, CertainTeed CT300M10-03 specs, utility payback rates, and NEC string calculators alongside Enphase Energy Inc XACM-IQ7-LR6-60PB-300M.

[All Enphase Energy Inc Certified Solar Models](https://epri-peac.com/solar-equipment/brands/enphase-energy-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Enphase Energy Inc

- [All Enphase Energy Inc Specs](https://epri-peac.com/solar-equipment/brands/enphase-energy-inc/)
- [Enphase Energy Inc XACM-IQ7-LR6-60PB-305M](https://epri-peac.com/solar-equipment/modules/enphase-energy-inc/enphase-energy-inc-xacm-iq7-lr6-60pb-305m/)
