title: "Enp Sonne Solar Technikk Specs (170.0W, 44.2V Voc)"
url: https://epri-peac.com/solar-equipment/modules/enp-sonne-solar-technikk/enp-sonne-solar-technikk-enp-m170mo/
description: "CEC datasheet for Enp Sonne Solar Technikk ENP-M170MO: 170.0W STC, 44.2V Voc, 48-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# Enp Sonne Solar Technikk ENP-M170MO — CEC Solar Module Specifications

Manufacturer: [**Enp Sonne Solar Technikk**](https://epri-peac.com/solar-equipment/brands/enp-sonne-solar-technikk/) Registry: **CEC Verified Engineering Specification**

Enp Sonne Solar Technikk ENP-M170MO is a 170.0 W STC (151.8 W PTC) Mono-c-Si solar module ranking #21,323 of 21,677 CEC listings (below all-CEC median; higher than 1.5% of peers). It delivers 13.29% efficiency, 44.2 V Voc at 25 C, and 50.06 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 170.0 W

- **PTC Wattage** : 151.8 W

- **Voc @ 25C** : 44.2 V

- **Efficiency** : 13.29%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Enp Sonne Solar Technikk ENP-M170MO Compare Against Peer CEC Listings?

How Enp Sonne Solar Technikk Enp Sonne Solar Technikk ENP-M170MO handles rooftop heat (151.8 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Enp Sonne Solar Technikk ENP-M170MO exhibits 5.15 A short-circuit current, requiring a 8.03 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #21,323 of 21,677 (240.0 W below the 410.0 W Mono-c-Si median), this compact residential or specialty off-grid module covers 61.4 m2 for an 8 kW system (59 panels for 10 kW). Mid-range 44.2 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F.

## Where Does Enp Sonne Solar Technikk ENP-M170MO Fall Across Listed CEC Models?

Where Enp Sonne Solar Technikk ENP-M170MO (170.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Enp Sonne Solar Technikk ENP-M170MO?

Percentile placement of Enp Sonne Solar Technikk ENP-M170MO across power density (132.9 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for Enp Sonne Solar Technikk ENP-M170MO?

Four critical engineering numbers homeowners and solar installers check first when reviewing Enp Sonne Solar Technikk ENP-M170MO specifications.

Rank #21,323 / 21,677

### 170.0 W STC · Higher Than 1.5%

170.0 W STC (-215.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #21,324

### 13.29% Aperture Efficiency

Power density 132.9 W/m2 (6.62 percentage points below 19.91% CEC median). PTC/STC ratio: 89.3% (rank #20,205).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 50.06 V at -10 C (550.7 V string) and 51.74 V at -20 C (11 max).

 8 kW Reference Array

### 48 Panels = 8,160 W STC

Occupies 61.4 m2 (661 sq ft) producing 7,286 W PTC; NEC 690.8 OCPD floor is 8.03 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 44.2 * (1 + (-0.379/100) * (-10 - 25)) = 50.06 V | OCPD = 1.56 * 5.15 = 8.03 A

Inputs from CEC Modules.csv for Enp Sonne Solar Technikk ENP-M170MO: Voc=44.2 V, beta_Voc=-0.379%/C, Isc=5.15 A, STC=170.0 W, Area=1.279 m2.

**Result:** 11 panels max on 600 V (550.7 V); 48 panels for 8 kW (661 sq ft).

## What Are the Published CEC Specifications for Enp Sonne Solar Technikk ENP-M170MO?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Enp Sonne Solar Technikk ENP-M170MO.

Official California Energy Commission (NREL SAM) test parameters for Enp Sonne Solar Technikk ENP-M170MO.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 170.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 151.8 W (89.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 44.2 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 5.15 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 35.0 V / 4.78 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.379 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 13.29% (1.279 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Enp Sonne Solar Technikk ENP-M170MO Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Enp Sonne Solar Technikk ENP-M170MO (170.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 36 | 6.12 kW | 496 sq ft | $1,532 | $2,590 |
| **8 kW Class** | 48 | 8.16 kW | 661 sq ft | $2,042 | $3,454 |
| **10 kW Class** | 59 | 10.03 kW | 812 sq ft | $2,510 | $4,245 |

## Which Sibling Wattage & Trim Variants Belong to This Enp Sonne Solar Technikk Series?

All closely matched Enp Sonne Solar Technikk wattages and cosmetic trims sharing the Enp Sonne Solar Technikk ENP-M170MO architecture.

Sibling CEC listings grouped into the Enp Sonne Solar Technikk ENP-M170MO wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Enp Sonne Solar Technikk ENP-M165MO** | 165.0 W | 147.3 W | 43.6 V | 35.4 V | 12.9% |
| **Enp Sonne Solar Technikk ENP-M170MO** | 170.0 W | 151.8 W | 44.2 V | 35.0 V | 13.29% |

## How Many Enp Sonne Solar Technikk ENP-M170MO Modules Fit in a Cold-Weather String?

Maximum series module counts for Enp Sonne Solar Technikk ENP-M170MO from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=44.2V and beta_Voc=-0.379%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 51.74 V | 11 panels | 569.1 V | 19 panels |
| **-10 C (14 F)** | 50.06 V | 11 panels | 550.7 V | 19 panels |
| **0 C (32 F)** | 48.39 V | 12 panels | 580.7 V | 20 panels |
| **25 C (77 F STC)** | 44.2 V | 13 panels | 574.6 V | 22 panels |

## Which Cross-Brand Solar Modules Compare Closest to Enp Sonne Solar Technikk ENP-M170MO?

Alternative CEC solar modules from competing brands near Enp Sonne Solar Technikk ENP-M170MO (170.0 W), including Hanwha Qcells (Qidong) Co Ltd SF160-24-P170.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Hanwha Qcells (Qidong) Co Ltd SF160-24-P170**](https://epri-peac.com/solar-equipment/modules/hanwha-qcells-qidong-co-ltd/hanwha-qcells-qidong-co-ltd-sf160-24-p170/) Hanwha Qcells (Qidong) Co Ltd | 170.0 W | Tie (0 W) | 44.1 V | 13.32% | 88.2% |
| [**Jiangyin Hareon Power HR-170W/24V**](https://epri-peac.com/solar-equipment/modules/jiangyin-hareon-power/jiangyin-hareon-power-hr-170w-24v/) Jiangyin Hareon Power | 170.0 W | Tie (0 W) | 43.8 V | 13.32% | 89.8% |
| [**Suntech Power STP170S-24/Ad+**](https://epri-peac.com/solar-equipment/modules/suntech-power/suntech-power-stp170s-24-ad/) Suntech Power | 170.0 W | Tie (0 W) | 43.8 V | 13.32% | 89.1% |
| [**Suntech Power STP170S-24/Adb+**](https://epri-peac.com/solar-equipment/modules/suntech-power/suntech-power-stp170s-24-adb/) Suntech Power | 170.0 W | Tie (0 W) | 43.8 V | 13.32% | 89.9% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Enp Sonne Solar Technikk ENP-M170MO?

Evaluate Enp Sonne Solar Technikk ENP-M170MO (170.0 W STC, 44.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Enp Sonne Solar Technikk ENP-M170MO reaches 51.74 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 48 panels for an 8 kW build require 661 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 48 panels (661 sq ft).
- 2026 tax credit baseline: cash residential installs of Enp Sonne Solar Technikk ENP-M170MO carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Enp Sonne Solar Technikk ENP-M170MO 8 kW Residential Fit

Needs 48 modules (661 sq ft) with a 15 A string OCPD, offsetting ~$2,042/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Hanwha Qcells (Qidong) Co Ltd SF160-24-P170.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 151.8 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Enp Sonne Solar Technikk ENP-M170MO by Enp Sonne Solar Technikk grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is Enp Sonne Solar Technikk ENP-M170MO PTC wattage (151.8 W) lower than STC (170.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 151.8 W PTC (89.3% retention) across Enp Sonne Solar Technikk ENP-M170MO's 1.279 m2 aperture.

### Who should skip Enp Sonne Solar Technikk ENP-M170MO on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 48 Enp Sonne Solar Technikk ENP-M170MO panels (661 sq ft) leave unusable roof gaps vs. Hanwha Qcells (Qidong) Co Ltd SF160-24-P170.

### What is the 1,000 V commercial string limit for Enp Sonne Solar Technikk ENP-M170MO?

On 1,000 V commercial inverters at -10 C (50.06 V cold Voc), Enp Sonne Solar Technikk ENP-M170MO fits up to 19 panels per series string.

## Related Pages

Compare Enp Sonne Solar Technikk equipment, Hanwha Qcells (Qidong) Co Ltd SF160-24-P170 specs, utility payback rates, and NEC string calculators alongside Enp Sonne Solar Technikk ENP-M170MO.

[All Enp Sonne Solar Technikk Certified Solar Models](https://epri-peac.com/solar-equipment/brands/enp-sonne-solar-technikk/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Enp Sonne Solar Technikk

- [All Enp Sonne Solar Technikk Specs](https://epri-peac.com/solar-equipment/brands/enp-sonne-solar-technikk/)