title: "Elin Energy (Sirius PV) Specs (440.0W, 41.12V Voc)"
url: https://epri-peac.com/solar-equipment/modules/elin-energy-sirius-pv/elin-energy-sirius-pv-elnsm60m-hc-440/
description: "CEC datasheet for Elin Energy (Sirius PV) ELNSM60M-HC-440: 440.0W STC, 41.12V Voc, 19-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# Elin Energy (Sirius PV) ELNSM60M-HC-440 — CEC Solar Module Specifications

Manufacturer: [**Elin Energy (Sirius PV)**](https://epri-peac.com/solar-equipment/brands/elin-energy-sirius-pv/) Registry: **CEC Verified Engineering Specification**

Elin Energy (Sirius PV) ELNSM60M-HC-440 is a 440.0 W STC (414.6 W PTC) Mono-c-Si solar module ranking #6,418 of 21,677 CEC listings (top 31.6%; higher than 68.4% of peers). It delivers 20.47% efficiency, 41.12 V Voc at 25 C, and 44.49 V cold Voc at -10 C (13 panels max per 600 V string).

- **STC Wattage** : 440.0 W

- **PTC Wattage** : 414.6 W

- **Voc @ 25C** : 41.12 V

- **Efficiency** : 20.47%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Elin Energy (Sirius PV) ELNSM60M-HC-440 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Elin Energy (Sirius PV) ELNSM60M-HC-440 (Mono-c-Si) residential solar systems.

Homeowners evaluating Elin Energy (Sirius PV) ELNSM60M-HC-440 need 14 panels for 6 kW or 19 panels (440 sq ft) for an 8 kW array—well-proportioned for residential pitched roofs needing 19 panels (440 sq ft) for an 8 kW array. Under NEC 690.7(A), beta_Voc (-0.234%/C) pushes open-circuit voltage to 44.49 V at 14 F and 45.45 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

## Where Does Elin Energy (Sirius PV) ELNSM60M-HC-440 Fall Across Listed CEC Models?

Comparison of Elin Energy (Sirius PV) ELNSM60M-HC-440 (440.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

## What Dataset Percentiles Define Elin Energy (Sirius PV) ELNSM60M-HC-440?

Relative ranking of Elin Energy (Sirius PV) ELNSM60M-HC-440 across nameplate watts, 94.2% PTC thermal ratio, and module aperture efficiency.

## What Do the Dataset Ranks Show for Elin Energy (Sirius PV) ELNSM60M-HC-440?

Summary of Elin Energy (Sirius PV) ELNSM60M-HC-440 output rank, 8 kW array size (19 panels), efficiency rating, and 600 V string limit.

Rank #6,418 / 21,677

### Top 31.6% STC Output

440.0 W STC (+55.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #8,713

### 20.47% Aperture Efficiency

Power density 204.7 W/m2 (0.56 percentage points above 19.91% CEC median). PTC/STC ratio: 94.2% (rank #3,689).

NEC 690.7 Limit

### 13 Panels Max @ -10 C (600 V)

Cold Voc reaches 44.49 V at -10 C (578.4 V string) and 45.45 V at -20 C (13 max).

 8 kW Reference Array

### 19 Panels = 8,360 W STC

Occupies 40.9 m2 (440 sq ft) producing 7,877 W PTC; NEC 690.8 OCPD floor is 21.15 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 41.12 * (1 + (-0.234/100) * (-10 - 25)) = 44.49 V | OCPD = 1.56 * 13.56 = 21.15 A

Inputs from CEC Modules.csv for Elin Energy (Sirius PV) ELNSM60M-HC-440: Voc=41.12 V, beta_Voc=-0.234%/C, Isc=13.56 A, STC=440.0 W, Area=2.15 m2.

**Result:** 13 panels max on 600 V (578.4 V); 19 panels for 8 kW (440 sq ft).

## What Are the Published CEC Specifications for Elin Energy (Sirius PV) ELNSM60M-HC-440?

Complete CEC test sheet for Elin Energy (Sirius PV) ELNSM60M-HC-440 including Isc (13.56 A), Voc (41.12 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Elin Energy (Sirius PV) ELNSM60M-HC-440.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 440.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 414.6 W (94.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 41.12 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 13.56 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 34.08 V / 12.92 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.234 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 20.47% (2.15 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Elin Energy (Sirius PV) ELNSM60M-HC-440 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Elin Energy (Sirius PV) ELNSM60M-HC-440.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 14 | 6.16 kW | 324 sq ft | $1,542 | $2,607 |
| **8 kW Class** | 19 | 8.36 kW | 440 sq ft | $2,092 | $3,538 |
| **10 kW Class** | 23 | 10.12 kW | 532 sq ft | $2,533 | $4,283 |

## Which Sibling Wattage & Trim Variants Belong to This Elin Energy (Sirius PV) Series?

Related Elin Energy (Sirius PV) power steps and black/silver trims consolidated into this Elin Energy (Sirius PV) ELNSM60M-HC-440 series guide.

Sibling CEC listings grouped into the Elin Energy (Sirius PV) ELNSM60M-HC-440 wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Elin Energy (Sirius PV) ELNSM60M-HC-435** | 435.0 W | 410.3 W | 41.02 V | 33.98 V | 20.23% |
| **Elin Energy (Sirius PV) ELNSM60M-HC-440** | 440.0 W | 414.6 W | 41.12 V | 34.08 V | 20.47% |
| **Elin Energy (Sirius PV) ELNSM60M-HC-445** | 445.0 W | 419.4 W | 41.22 V | 34.18 V | 20.7% |

## How Many Elin Energy (Sirius PV) ELNSM60M-HC-440 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Elin Energy (Sirius PV) ELNSM60M-HC-440 (41.12 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=41.12V and beta_Voc=-0.234%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 45.45 V | 13 panels | 590.9 V | 22 panels |
| **-10 C (14 F)** | 44.49 V | 13 panels | 578.4 V | 22 panels |
| **0 C (32 F)** | 43.53 V | 13 panels | 565.9 V | 22 panels |
| **25 C (77 F STC)** | 41.12 V | 14 panels | 575.7 V | 24 panels |

## Which Cross-Brand Solar Modules Compare Closest to Elin Energy (Sirius PV) ELNSM60M-HC-440?

Four comparable CEC modules such as Aptos Solar Technology LLC DNA-120-MF10-440W-USAptos1 (440.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Aptos Solar Technology LLC DNA-120-MF10-440W-USAptos1**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-120-mf10-440w-usaptos1/) Aptos Solar Technology LLC | 440.0 W | Tie (0 W) | 41.18 V | 20.56% | 94.3% |
| [**Aptos Solar Technology LLC DNA-120-MF10-440W-USAptos2**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-120-mf10-440w-usaptos2/) Aptos Solar Technology LLC | 440.0 W | Tie (0 W) | 41.18 V | 20.56% | 94.3% |
| [**CertainTeed CTM10440HC11-06**](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-ctm10440hc11-06/) CertainTeed | 440.0 W | Tie (0 W) | 41.02 V | 20.37% | 93.7% |
| [**Changzhou EGing Photovoltaic Technology Co Ltd EG-440M60-HLV**](https://epri-peac.com/solar-equipment/modules/changzhou-eging-photovoltaic-technology-co-ltd/changzhou-eging-photovoltaic-technology-co-ltd-eg-440m60-hlv/) Changzhou EGing Photovoltaic Technology Co Ltd | 440.0 W | Tie (0 W) | 41.0 V | 20.37% | 93.7% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Elin Energy (Sirius PV) ELNSM60M-HC-440?

Evaluate Elin Energy (Sirius PV) ELNSM60M-HC-440 (440.0 W STC, 41.12 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Elin Energy (Sirius PV) ELNSM60M-HC-440 reaches 45.45 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 19 panels for an 8 kW build require 440 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (440 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Elin Energy (Sirius PV) ELNSM60M-HC-440 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Elin Energy (Sirius PV) ELNSM60M-HC-440 8 kW Residential Fit

Needs 19 modules (440 sq ft) with a 25 A string OCPD, offsetting ~$2,092/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Aptos Solar Technology LLC DNA-120-MF10-440W-USAptos1.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 414.6 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Elin Energy (Sirius PV) ELNSM60M-HC-440 by Elin Energy (Sirius PV) grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is Elin Energy (Sirius PV) ELNSM60M-HC-440 PTC wattage (414.6 W) lower than STC (440.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 414.6 W PTC (94.2% retention) across Elin Energy (Sirius PV) ELNSM60M-HC-440's 2.15 m2 aperture.

### Who should skip Elin Energy (Sirius PV) ELNSM60M-HC-440 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 19 Elin Energy (Sirius PV) ELNSM60M-HC-440 panels (440 sq ft) leave unusable roof gaps vs. Aptos Solar Technology LLC DNA-120-MF10-440W-USAptos1.

### What is the 1,000 V commercial string limit for Elin Energy (Sirius PV) ELNSM60M-HC-440?

On 1,000 V commercial inverters at -10 C (44.49 V cold Voc), Elin Energy (Sirius PV) ELNSM60M-HC-440 fits up to 22 panels per series string.

## Related Pages

Compare Elin Energy (Sirius PV) equipment, Aptos Solar Technology LLC DNA-120-MF10-440W-USAptos1 specs, utility payback rates, and NEC string calculators alongside Elin Energy (Sirius PV) ELNSM60M-HC-440.

[All Elin Energy (Sirius PV) Certified Solar Models](https://epri-peac.com/solar-equipment/brands/elin-energy-sirius-pv/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Elin Energy (Sirius PV)

- [All Elin Energy (Sirius PV) Specs](https://epri-peac.com/solar-equipment/brands/elin-energy-sirius-pv/)
- [Elin Energy (Sirius PV) ELNSM78M-HC-610](https://epri-peac.com/solar-equipment/modules/elin-energy-sirius-pv/elin-energy-sirius-pv-elnsm78m-hc-610/)
- [Elin Energy (Sirius PV) ELNSM78M-HC-BF-610](https://epri-peac.com/solar-equipment/modules/elin-energy-sirius-pv/elin-energy-sirius-pv-elnsm78m-hc-bf-610/)
- [Elin Energy (Sirius PV) ELNSM78M-HC-LV-610](https://epri-peac.com/solar-equipment/modules/elin-energy-sirius-pv/elin-energy-sirius-pv-elnsm78m-hc-lv-610/)
- [Elin Energy (Sirius PV) ELNSM78M-HC-590](https://epri-peac.com/solar-equipment/modules/elin-energy-sirius-pv/elin-energy-sirius-pv-elnsm78m-hc-590/)
- [Elin Energy (Sirius PV) ELNSM78M-HC-BF-590](https://epri-peac.com/solar-equipment/modules/elin-energy-sirius-pv/elin-energy-sirius-pv-elnsm78m-hc-bf-590/)