# DualSun SAS DualSun 435M-144-01 — CEC Solar Module Specifications

Manufacturer: [**DualSun SAS**](https://epri-peac.com/solar-equipment/brands/dualsun-sas/) Registry: **CEC Verified Engineering Specification**

DualSun SAS DualSun 435M-144-01 is a 435.0 W STC (408.5 W PTC) Mono-c-Si solar module ranking #6,850 of 21,677 CEC listings (top 33.5%; higher than 66.5% of peers). It delivers 20.14% efficiency, 49.4 V Voc at 25 C, and 54.03 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 435.0 W

- **PTC Wattage** : 408.5 W

- **Voc @ 25C** : 49.4 V

- **Efficiency** : 20.14%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does DualSun SAS DualSun 435M-144-01 Compare Against Peer CEC Listings?

Solar engineering breakdown for DualSun SAS DualSun 435M-144-01: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 435.0 W STC and 408.5 W PTC, DualSun SAS DualSun 435M-144-01 sits +50.0 W vs all-CEC median (top 33.5%; higher than 66.5% of peers) among 21,677 listed modules. Power density reaches 201.4 W/m2 (0.23 percentage points above 19.91% CEC median). Higher 49.4 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C), whereas 1,000 V commercial inverters handle up to 18 panels in series. Alternative peer AXITEC AC-435MH/144V rates 435.0 W.

## Where Does DualSun SAS DualSun 435M-144-01 Fall Across Listed CEC Models?

Distribution marker showing DualSun SAS DualSun 435M-144-01 (435.0 W) relative to the 385.0 W all-CEC solar panel median.

## What Dataset Percentiles Define DualSun SAS DualSun 435M-144-01?

Dataset percentiles tracking DualSun SAS DualSun 435M-144-01 power output, thermal retention ratio, and aperture efficiency against 21,677 models.

## What Do the Dataset Ranks Show for DualSun SAS DualSun 435M-144-01?

Benchmark highlights for DualSun SAS DualSun 435M-144-01 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #6,850 / 21,677

### Top 33.5% STC Output

435.0 W STC (+50.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #9,983

### 20.14% Aperture Efficiency

Power density 201.4 W/m2 (0.23 percentage points above 19.91% CEC median). PTC/STC ratio: 93.9% (rank #5,210).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 54.03 V at -10 C (594.3 V string) and 55.36 V at -20 C (10 max).

 8 kW Reference Array

### 19 Panels = 8,265 W STC

Occupies 41.0 m2 (442 sq ft) producing 7,762 W PTC; NEC 690.8 OCPD floor is 17.57 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.4 * (1 + (-0.268/100) * (-10 - 25)) = 54.03 V | OCPD = 1.56 * 11.26 = 17.57 A

Inputs from CEC Modules.csv for DualSun SAS DualSun 435M-144-01: Voc=49.4 V, beta_Voc=-0.268%/C, Isc=11.26 A, STC=435.0 W, Area=2.16 m2.

**Result:** 11 panels max on 600 V (594.3 V); 19 panels for 8 kW (442 sq ft).

## What Are the Published CEC Specifications for DualSun SAS DualSun 435M-144-01?

Official CEC datasheet figures for DualSun SAS DualSun 435M-144-01 (Mono-c-Si) used in utility interconnection and permit reviews. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Official California Energy Commission (NREL SAM) test parameters for DualSun SAS DualSun 435M-144-01.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 435.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 408.5 W (93.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 49.4 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 11.26 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 40.8 V / 10.67 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.268 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 20.14% (2.16 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Monofacial backsheet |

## How Many DualSun SAS DualSun 435M-144-01 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many DualSun SAS DualSun 435M-144-01 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 14 | 6.09 kW | 326 sq ft | $1,524 | $2,577 |
| **8 kW Class** | 19 | 8.27 kW | 442 sq ft | $2,070 | $3,500 |
| **10 kW Class** | 23 | 10.01 kW | 535 sq ft | $2,505 | $4,236 |

## Which Sibling Wattage & Trim Variants Belong to This DualSun SAS Series?

Consolidated DualSun SAS wattage variants sharing the DualSun SAS DualSun 435M-144-01 mechanical and cell layout. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Sibling CEC listings grouped into the DualSun SAS DualSun 435M-144-01 wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **DualSun SAS DualSun 425M-144-01** | 425.0 W | 398.9 W | 49.0 V | 40.4 V | 19.68% |
| **DualSun SAS DualSun 430M-144-01** | 430.0 W | 403.7 W | 49.2 V | 40.6 V | 19.91% |
| **DualSun SAS DualSun 435M-144-01** | 435.0 W | 408.5 W | 49.4 V | 40.8 V | 20.14% |
| **DualSun SAS DualSun 440M-144-01** | 440.0 W | 413.3 W | 49.6 V | 41.0 V | 20.37% |

## How Many DualSun SAS DualSun 435M-144-01 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on DualSun SAS DualSun 435M-144-01 (54.03 V at 14 F).

Computed from Voc=49.4V and beta_Voc=-0.268%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 55.36 V | 10 panels | 553.6 V | 18 panels |
| **-10 C (14 F)** | 54.03 V | 11 panels | 594.3 V | 18 panels |
| **0 C (32 F)** | 52.71 V | 11 panels | 579.8 V | 18 panels |
| **25 C (77 F STC)** | 49.4 V | 12 panels | 592.8 V | 20 panels |

## Which Cross-Brand Solar Modules Compare Closest to DualSun SAS DualSun 435M-144-01?

Competing CEC solar panels closest to DualSun SAS DualSun 435M-144-01 in nameplate wattage and Voc, starting with AXITEC AC-435MH/144V.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**AXITEC AC-435MH/144V**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-435mh-144v/) AXITEC | 435.0 W | Tie (0 W) | 49.4 V | 20.52% | 92.4% |
| [**Dehui Solar Power (Vietnam) CoLtd DH-M772W 435W**](https://epri-peac.com/solar-equipment/modules/dehui-solar-power-vietnam-coltd/dehui-solar-power-vietnam-coltd-dh-m772w-435w/) Dehui Solar Power (Vietnam) CoLtd | 435.0 W | Tie (0 W) | 49.4 V | 20.52% | 92.4% |
| [**AXITEC AC-435MB/144V**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-435mb-144v/) AXITEC | 435.0 W | Tie (0 W) | 49.1 V | 20.33% | 92.6% |
| [**Dehui Solar Power (Vietnam) CoLtd DH-M772F 435W**](https://epri-peac.com/solar-equipment/modules/dehui-solar-power-vietnam-coltd/dehui-solar-power-vietnam-coltd-dh-m772f-435w/) Dehui Solar Power (Vietnam) CoLtd | 435.0 W | Tie (0 W) | 49.1 V | 20.33% | 92.6% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for DualSun SAS DualSun 435M-144-01?

Evaluate DualSun SAS DualSun 435M-144-01 (435.0 W STC, 49.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), DualSun SAS DualSun 435M-144-01 reaches 55.36 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 19 panels for an 8 kW build require 442 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (442 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of DualSun SAS DualSun 435M-144-01 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### DualSun SAS DualSun 435M-144-01 8 kW Residential Fit

Needs 19 modules (442 sq ft) with a 20 A string OCPD, offsetting ~$2,070/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare AXITEC AC-435MH/144V.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 408.5 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for DualSun SAS DualSun 435M-144-01 by DualSun SAS grounded in CEC test data and NEC 690.7/690.8 limits.

### How many DualSun SAS DualSun 435M-144-01 panels fit on a 600 V winter solar string?

At -10 C (14 F), DualSun SAS DualSun 435M-144-01 cold Voc rises from 49.4 V to 54.03 V (beta_Voc -0.268%/C), capping a 600 V string at 11 panels (594.3 V).

### How much roof area does an 8 kW array of DualSun SAS DualSun 435M-144-01 need?

An 8 kW DC system uses 19 DualSun SAS DualSun 435M-144-01 modules (8,265 W STC / 7,762 W PTC), covering roughly 442 sq ft and saving ~$2,070/yr at 18.54 c/kWh.

### How does DualSun SAS DualSun 435M-144-01 compare against AXITEC AC-435MH/144V?

DualSun SAS DualSun 435M-144-01 outputs 435.0 W STC (49.4 V Voc, rank #6,850 of 21,677), while AXITEC AC-435MH/144V delivers 435.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare DualSun SAS equipment, AXITEC AC-435MH/144V specs, utility payback rates, and NEC string calculators alongside DualSun SAS DualSun 435M-144-01.

[All DualSun SAS Certified Solar Models](https://epri-peac.com/solar-equipment/brands/dualsun-sas/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From DualSun SAS

- [All DualSun SAS Specs](https://epri-peac.com/solar-equipment/brands/dualsun-sas/)
- [DualSun SAS DSTN425M12-B320SBB7](https://epri-peac.com/solar-equipment/modules/dualsun-sas/dualsun-sas-dstn425m12-b320sbb7/)
- [DualSun SAS DualSun 420M-144-01](https://epri-peac.com/solar-equipment/modules/dualsun-sas/dualsun-sas-dualsun-420m-144-01/)
- [DualSun SAS DualSun 380M-120-01](https://epri-peac.com/solar-equipment/modules/dualsun-sas/dualsun-sas-dualsun-380m-120-01/)
- [DualSun SAS DualSun 360M-120-00](https://epri-peac.com/solar-equipment/modules/dualsun-sas/dualsun-sas-dualsun-360m-120-00/)
- [DualSun SAS DualSun 360M-120-01](https://epri-peac.com/solar-equipment/modules/dualsun-sas/dualsun-sas-dualsun-360m-120-01/)