title: "Du Pont Apollo DA105-A2 Specs (105.0W, 100.0V Voc)"
url: https://epri-peac.com/solar-equipment/modules/du-pont-apollo/du-pont-apollo-da105-a2/
description: "CEC datasheet for Du Pont Apollo DA105-A2: 105.0W STC, 100.0V Voc, 77-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# Du Pont Apollo DA105-A2 — CEC Solar Module Specifications

Manufacturer: [**Du Pont Apollo**](https://epri-peac.com/solar-equipment/brands/du-pont-apollo/) Registry: **CEC Verified Engineering Specification**

Du Pont Apollo DA105-A2 is a 105.0 W STC (95.5 W PTC) Thin Film solar module ranking #21,543 of 21,677 CEC listings (below all-CEC median; higher than 0.6% of peers). It delivers 6.82% efficiency, 100.0 V Voc at 25 C, and 111.48 V cold Voc at -10 C (5 panels max per 600 V string).

- **STC Wattage** : 105.0 W

- **PTC Wattage** : 95.5 W

- **Voc @ 25C** : 100.0 V

- **Efficiency** : 6.82%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Du Pont Apollo DA105-A2 Compare Against Peer CEC Listings?

Solar engineering breakdown for Du Pont Apollo DA105-A2: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 105.0 W STC and 95.5 W PTC, Du Pont Apollo DA105-A2 sits -280.0 W vs all-CEC median (below all-CEC median; higher than 0.6% of peers) among 21,677 listed modules. Power density reaches 68.2 W/m2 (13.09 percentage points below 19.91% CEC median). Higher 100.0 V open-circuit voltage caps 600 V residential strings at 5 panels at 14 F (-10 C), whereas 1,000 V commercial inverters handle up to 8 panels in series. Alternative peer Applied Materials 1/4 Size Single Junction Version 10 rates 116.0 W.

## Where Does Du Pont Apollo DA105-A2 Fall Across Listed CEC Models?

Distribution marker showing Du Pont Apollo DA105-A2 (105.0 W) relative to the 385.0 W all-CEC solar panel median.

## What Dataset Percentiles Define Du Pont Apollo DA105-A2?

Dataset percentiles tracking Du Pont Apollo DA105-A2 power output, thermal retention ratio, and aperture efficiency against 21,677 models.

## What Do the Dataset Ranks Show for Du Pont Apollo DA105-A2?

Benchmark highlights for Du Pont Apollo DA105-A2 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #21,543 / 21,677

### 105.0 W STC · Higher Than 0.6%

105.0 W STC (-280.0 W vs all-CEC median) vs 117.5 W Thin Film median.

Eff #21,666

### 6.82% Aperture Efficiency

Power density 68.2 W/m2 (13.09 percentage points below 19.91% CEC median). PTC/STC ratio: 91.0% (rank #16,685).

NEC 690.7 Limit

### 5 Panels Max @ -10 C (600 V)

Cold Voc reaches 111.48 V at -10 C (557.4 V string) and 114.76 V at -20 C (5 max).

 8 kW Reference Array

### 77 Panels = 8,085 W STC

Occupies 118.6 m2 (1,276 sq ft) producing 7,354 W PTC; NEC 690.8 OCPD floor is 2.59 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 100.0 * (1 + (-0.328/100) * (-10 - 25)) = 111.48 V | OCPD = 1.56 * 1.66 = 2.59 A

Inputs from CEC Modules.csv for Du Pont Apollo DA105-A2: Voc=100.0 V, beta_Voc=-0.328%/C, Isc=1.66 A, STC=105.0 W, Area=1.54 m2.

**Result:** 5 panels max on 600 V (557.4 V); 77 panels for 8 kW (1,276 sq ft).

## What Are the Published CEC Specifications for Du Pont Apollo DA105-A2?

Official CEC datasheet figures for Du Pont Apollo DA105-A2 (Thin Film) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for Du Pont Apollo DA105-A2.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 105.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 95.5 W (91.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 100.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 1.66 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 75.0 V / 1.4 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.328 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 6.82% (1.54 m2) | Array roof footprint density |
| **Cell Count & Technology** | 119 cells (Thin Film) | Monofacial backsheet |

## How Many Du Pont Apollo DA105-A2 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Du Pont Apollo DA105-A2 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 58 | 6.09 kW | 961 sq ft | $1,524 | $2,577 |
| **8 kW Class** | 77 | 8.09 kW | 1,276 sq ft | $2,025 | $3,424 |
| **10 kW Class** | 96 | 10.08 kW | 1,591 sq ft | $2,523 | $4,266 |

## Which Sibling Wattage & Trim Variants Belong to This Du Pont Apollo Series?

Consolidated Du Pont Apollo wattage variants sharing the Du Pont Apollo DA105-A2 mechanical and cell layout. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Sibling CEC listings grouped into the Du Pont Apollo DA105-A2 wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Du Pont Apollo DA100-A2** | 100.0 W | 90.9 W | 100.0 V | 75.0 V | 6.49% |
| **Du Pont Apollo DA105-A2** | 105.0 W | 95.5 W | 100.0 V | 75.0 V | 6.82% |

## How Many Du Pont Apollo DA105-A2 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Du Pont Apollo DA105-A2 (111.48 V at 14 F).

Computed from Voc=100.0V and beta_Voc=-0.328%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 114.76 V | 5 panels | 573.8 V | 8 panels |
| **-10 C (14 F)** | 111.48 V | 5 panels | 557.4 V | 8 panels |
| **0 C (32 F)** | 108.2 V | 5 panels | 541.0 V | 9 panels |
| **25 C (77 F STC)** | 100.0 V | 6 panels | 600.0 V | 10 panels |

## Which Cross-Brand Solar Modules Compare Closest to Du Pont Apollo DA105-A2?

Competing CEC solar panels closest to Du Pont Apollo DA105-A2 in nameplate wattage and Voc, starting with Applied Materials 1/4 Size Single Junction Version 10.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Applied Materials 1/4 Size Single Junction Version 10**](https://epri-peac.com/solar-equipment/modules/applied-materials/applied-materials-1-4-size-single-junction-version-10/) Applied Materials | 116.0 W | +11.0 W | 96.2 V | 8.11% | 93.0% |
| [**T-Solar Global TS102**](https://epri-peac.com/solar-equipment/modules/t-solar-global/t-solar-global-ts102/) T-Solar Global | 102.5 W | -2.5 W | 93.0 V | 7.19% | 93.0% |
| [**T-Solar Global TS97**](https://epri-peac.com/solar-equipment/modules/t-solar-global/t-solar-global-ts97/) T-Solar Global | 97.5 W | -7.5 W | 93.0 V | 6.84% | 92.9% |
| [**First Solar Inc FS-4105**](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-4105/) First Solar Inc | 105.0 W | Tie (0 W) | 88.2 V | 14.58% | 94.6% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Du Pont Apollo DA105-A2?

Evaluate Du Pont Apollo DA105-A2 (105.0 W STC, 100.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Du Pont Apollo DA105-A2 reaches 114.76 V per panel—exceeding 5 panels in series voids 600 V inverter warranties.
- Footprint constraint: 77 panels for an 8 kW build require 1,276 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 77 panels (1,276 sq ft).
- 2026 tax credit baseline: cash residential installs of Du Pont Apollo DA105-A2 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Du Pont Apollo DA105-A2 8 kW Residential Fit

Needs 77 modules (1,276 sq ft) with a 15 A string OCPD, offsetting ~$2,025/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 5 panels (-10 C) or 5 panels (-20 C), or compare Applied Materials 1/4 Size Single Junction Version 10.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 95.5 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Du Pont Apollo DA105-A2 by Du Pont Apollo grounded in CEC test data and NEC 690.7/690.8 limits.

### How many Du Pont Apollo DA105-A2 panels fit on a 600 V winter solar string?

At -10 C (14 F), Du Pont Apollo DA105-A2 cold Voc rises from 100.0 V to 111.48 V (beta_Voc -0.328%/C), capping a 600 V string at 5 panels (557.4 V).

### How much roof area does an 8 kW array of Du Pont Apollo DA105-A2 need?

An 8 kW DC system uses 77 Du Pont Apollo DA105-A2 modules (8,085 W STC / 7,354 W PTC), covering roughly 1,276 sq ft and saving ~$2,025/yr at 18.54 c/kWh.

### How does Du Pont Apollo DA105-A2 compare against Applied Materials 1/4 Size Single Junction Version 10?

Du Pont Apollo DA105-A2 outputs 105.0 W STC (100.0 V Voc, rank #21,543 of 21,677), while Applied Materials 1/4 Size Single Junction Version 10 delivers 116.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare Du Pont Apollo equipment, Applied Materials 1/4 Size Single Junction Version 10 specs, utility payback rates, and NEC string calculators alongside Du Pont Apollo DA105-A2.

[All Du Pont Apollo Certified Solar Models](https://epri-peac.com/solar-equipment/brands/du-pont-apollo/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Du Pont Apollo

- [All Du Pont Apollo Specs](https://epri-peac.com/solar-equipment/brands/du-pont-apollo/)
- [Du Pont Apollo DA133-C2](https://epri-peac.com/solar-equipment/modules/du-pont-apollo/du-pont-apollo-da133-c2/)
- [Du Pont Apollo DA102-A6](https://epri-peac.com/solar-equipment/modules/du-pont-apollo/du-pont-apollo-da102-a6/)
- [Du Pont Apollo DA095-A2](https://epri-peac.com/solar-equipment/modules/du-pont-apollo/du-pont-apollo-da095-a2/)