title: "Du Pont Apollo DA095-A2 Specs (95.0W, 100.0V Voc)"
url: https://epri-peac.com/solar-equipment/modules/du-pont-apollo/du-pont-apollo-da095-a2/
description: "CEC datasheet for Du Pont Apollo DA095-A2: 95.0W STC, 100.0V Voc, 85-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# Du Pont Apollo DA095-A2 — CEC Solar Module Specifications

Manufacturer: [**Du Pont Apollo**](https://epri-peac.com/solar-equipment/brands/du-pont-apollo/) Registry: **CEC Verified Engineering Specification**

Du Pont Apollo DA095-A2 is a 95.0 W STC (86.3 W PTC) Thin Film solar module ranking #21,579 of 21,677 CEC listings (below all-CEC median; higher than 0.4% of peers). It delivers 6.17% efficiency, 100.0 V Voc at 25 C, and 111.48 V cold Voc at -10 C (5 panels max per 600 V string).

- **STC Wattage** : 95.0 W

- **PTC Wattage** : 86.3 W

- **Voc @ 25C** : 100.0 V

- **Efficiency** : 6.17%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Du Pont Apollo DA095-A2 Compare Against Peer CEC Listings?

Solar engineering breakdown for Du Pont Apollo DA095-A2: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 95.0 W STC and 86.3 W PTC, Du Pont Apollo DA095-A2 sits -290.0 W vs all-CEC median (below all-CEC median; higher than 0.4% of peers) among 21,677 listed modules. Power density reaches 61.7 W/m2 (13.74 percentage points below 19.91% CEC median). Higher 100.0 V open-circuit voltage caps 600 V residential strings at 5 panels at 14 F (-10 C), whereas 1,000 V commercial inverters handle up to 8 panels in series. Alternative peer T-Solar Global TS97 rates 97.5 W.

## Where Does Du Pont Apollo DA095-A2 Fall Across Listed CEC Models?

Distribution marker showing Du Pont Apollo DA095-A2 (95.0 W) relative to the 385.0 W all-CEC solar panel median.

## What Dataset Percentiles Define Du Pont Apollo DA095-A2?

Dataset percentiles tracking Du Pont Apollo DA095-A2 power output, thermal retention ratio, and aperture efficiency against 21,677 models.

## What Do the Dataset Ranks Show for Du Pont Apollo DA095-A2?

Benchmark highlights for Du Pont Apollo DA095-A2 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #21,579 / 21,677

### 95.0 W STC · Higher Than 0.4%

95.0 W STC (-290.0 W vs all-CEC median) vs 117.5 W Thin Film median.

Eff #21,676

### 6.17% Aperture Efficiency

Power density 61.7 W/m2 (13.74 percentage points below 19.91% CEC median). PTC/STC ratio: 90.8% (rank #17,104).

NEC 690.7 Limit

### 5 Panels Max @ -10 C (600 V)

Cold Voc reaches 111.48 V at -10 C (557.4 V string) and 114.76 V at -20 C (5 max).

 8 kW Reference Array

### 85 Panels = 8,075 W STC

Occupies 130.9 m2 (1,409 sq ft) producing 7,336 W PTC; NEC 690.8 OCPD floor is 2.53 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 100.0 * (1 + (-0.328/100) * (-10 - 25)) = 111.48 V | OCPD = 1.56 * 1.62 = 2.53 A

Inputs from CEC Modules.csv for Du Pont Apollo DA095-A2: Voc=100.0 V, beta_Voc=-0.328%/C, Isc=1.62 A, STC=95.0 W, Area=1.54 m2.

**Result:** 5 panels max on 600 V (557.4 V); 85 panels for 8 kW (1,409 sq ft).

## What Are the Published CEC Specifications for Du Pont Apollo DA095-A2?

Official CEC datasheet figures for Du Pont Apollo DA095-A2 (Thin Film) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for Du Pont Apollo DA095-A2.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 95.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 86.3 W (90.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 100.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 1.62 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 73.0 V / 1.3 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.328 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 6.17% (1.54 m2) | Array roof footprint density |
| **Cell Count & Technology** | 119 cells (Thin Film) | Monofacial backsheet |

## How Many Du Pont Apollo DA095-A2 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Du Pont Apollo DA095-A2 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 64 | 6.08 kW | 1,061 sq ft | $1,522 | $2,573 |
| **8 kW Class** | 85 | 8.07 kW | 1,409 sq ft | $2,020 | $3,415 |
| **10 kW Class** | 106 | 10.07 kW | 1,757 sq ft | $2,520 | $4,262 |

## How Many Du Pont Apollo DA095-A2 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Du Pont Apollo DA095-A2 (111.48 V at 14 F).

Computed from Voc=100.0V and beta_Voc=-0.328%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 114.76 V | 5 panels | 573.8 V | 8 panels |
| **-10 C (14 F)** | 111.48 V | 5 panels | 557.4 V | 8 panels |
| **0 C (32 F)** | 108.2 V | 5 panels | 541.0 V | 9 panels |
| **25 C (77 F STC)** | 100.0 V | 6 panels | 600.0 V | 10 panels |

## Which Cross-Brand Solar Modules Compare Closest to Du Pont Apollo DA095-A2?

Competing CEC solar panels closest to Du Pont Apollo DA095-A2 in nameplate wattage and Voc, starting with T-Solar Global TS97.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**T-Solar Global TS97**](https://epri-peac.com/solar-equipment/modules/t-solar-global/t-solar-global-ts97/) T-Solar Global | 97.5 W | +2.5 W | 93.0 V | 6.84% | 92.9% |
| [**T-Solar Global TS102**](https://epri-peac.com/solar-equipment/modules/t-solar-global/t-solar-global-ts102/) T-Solar Global | 102.5 W | +7.5 W | 93.0 V | 7.19% | 93.0% |
| [**Applied Materials 1/4 Size Single Junction Version 10**](https://epri-peac.com/solar-equipment/modules/applied-materials/applied-materials-1-4-size-single-junction-version-10/) Applied Materials | 116.0 W | +21.0 W | 96.2 V | 8.11% | 93.0% |
| [**First Solar Inc FS-277**](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-277/) First Solar Inc | 77.5 W | -17.5 W | 93.0 V | 10.76% | 96.3% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Du Pont Apollo DA095-A2?

Evaluate Du Pont Apollo DA095-A2 (95.0 W STC, 100.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Du Pont Apollo DA095-A2 reaches 114.76 V per panel—exceeding 5 panels in series voids 600 V inverter warranties.
- Footprint constraint: 85 panels for an 8 kW build require 1,409 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 85 panels (1,409 sq ft).
- 2026 tax credit baseline: cash residential installs of Du Pont Apollo DA095-A2 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Du Pont Apollo DA095-A2 8 kW Residential Fit

Needs 85 modules (1,409 sq ft) with a 15 A string OCPD, offsetting ~$2,020/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 5 panels (-10 C) or 5 panels (-20 C), or compare T-Solar Global TS97.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 86.3 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Du Pont Apollo DA095-A2 by Du Pont Apollo grounded in CEC test data and NEC 690.7/690.8 limits.

### How many Du Pont Apollo DA095-A2 panels fit on a 600 V winter solar string?

At -10 C (14 F), Du Pont Apollo DA095-A2 cold Voc rises from 100.0 V to 111.48 V (beta_Voc -0.328%/C), capping a 600 V string at 5 panels (557.4 V).

### How much roof area does an 8 kW array of Du Pont Apollo DA095-A2 need?

An 8 kW DC system uses 85 Du Pont Apollo DA095-A2 modules (8,075 W STC / 7,336 W PTC), covering roughly 1,409 sq ft and saving ~$2,020/yr at 18.54 c/kWh.

### How does Du Pont Apollo DA095-A2 compare against T-Solar Global TS97?

Du Pont Apollo DA095-A2 outputs 95.0 W STC (100.0 V Voc, rank #21,579 of 21,677), while T-Solar Global TS97 delivers 97.5 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare Du Pont Apollo equipment, T-Solar Global TS97 specs, utility payback rates, and NEC string calculators alongside Du Pont Apollo DA095-A2.

[All Du Pont Apollo Certified Solar Models](https://epri-peac.com/solar-equipment/brands/du-pont-apollo/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Du Pont Apollo

- [All Du Pont Apollo Specs](https://epri-peac.com/solar-equipment/brands/du-pont-apollo/)
- [Du Pont Apollo DA133-C2](https://epri-peac.com/solar-equipment/modules/du-pont-apollo/du-pont-apollo-da133-c2/)
- [Du Pont Apollo DA105-A2](https://epri-peac.com/solar-equipment/modules/du-pont-apollo/du-pont-apollo-da105-a2/)
- [Du Pont Apollo DA102-A6](https://epri-peac.com/solar-equipment/modules/du-pont-apollo/du-pont-apollo-da102-a6/)