title: "Crossroads Solar Crossroads Solar Specs (380.0W, 49.0V Voc)"
url: https://epri-peac.com/solar-equipment/modules/crossroads-solar/crossroads-solar-crossroads-solar-380/
description: "CEC datasheet for Crossroads Solar Crossroads Solar 380: 380.0W STC, 49.0V Voc, 22-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# Crossroads Solar Crossroads Solar 380 — CEC Solar Module Specifications

Manufacturer: [**Crossroads Solar**](https://epri-peac.com/solar-equipment/brands/crossroads-solar/) Registry: **CEC Verified Engineering Specification**

Crossroads Solar Crossroads Solar 380 is a 380.0 W STC (350.5 W PTC) Mono-c-Si solar module ranking #11,043 of 21,677 CEC listings (below all-CEC median; higher than 47.6% of peers). It delivers 18.63% efficiency, 49.0 V Voc at 25 C, and 53.77 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 380.0 W

- **PTC Wattage** : 350.5 W

- **Voc @ 25C** : 49.0 V

- **Efficiency** : 18.63%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Crossroads Solar Crossroads Solar 380 Compare Against Peer CEC Listings?

Solar engineering breakdown for Crossroads Solar Crossroads Solar 380: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 5,889 Mono-c-Si listings from Crossroads Solar and peers, Crossroads Solar Crossroads Solar 380 stands 30.0 W below the 410.0 W Mono-c-Si median and strong 92.2% PTC-to-STC heat retention (#13,542 of 21,677). Sizing 6 kW (16 panels) to 10 kW (27 panels) yields $1,522-$2,568/yr in baseline US bill offset. Higher 49.0 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C).

## Where Does Crossroads Solar Crossroads Solar 380 Fall Across Listed CEC Models?

Distribution marker showing Crossroads Solar Crossroads Solar 380 (380.0 W) relative to the 385.0 W all-CEC solar panel median.

## What Dataset Percentiles Define Crossroads Solar Crossroads Solar 380?

Dataset percentiles tracking Crossroads Solar Crossroads Solar 380 power output, thermal retention ratio, and aperture efficiency against 21,677 models.

## What Do the Dataset Ranks Show for Crossroads Solar Crossroads Solar 380?

Benchmark highlights for Crossroads Solar Crossroads Solar 380 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #11,043 / 21,677

### 380.0 W STC · Higher Than 47.6%

380.0 W STC (-5.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #14,148

### 18.63% Aperture Efficiency

Power density 186.3 W/m2 (1.28 percentage points below 19.91% CEC median). PTC/STC ratio: 92.2% (rank #13,542).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 53.77 V at -10 C (591.5 V string) and 55.13 V at -20 C (10 max).

 8 kW Reference Array

### 22 Panels = 8,360 W STC

Occupies 44.9 m2 (483 sq ft) producing 7,711 W PTC; NEC 690.8 OCPD floor is 15.44 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.0 * (1 + (-0.278/100) * (-10 - 25)) = 53.77 V | OCPD = 1.56 * 9.9 = 15.44 A

Inputs from CEC Modules.csv for Crossroads Solar Crossroads Solar 380: Voc=49.0 V, beta_Voc=-0.278%/C, Isc=9.9 A, STC=380.0 W, Area=2.04 m2.

**Result:** 11 panels max on 600 V (591.5 V); 22 panels for 8 kW (483 sq ft).

## What Are the Published CEC Specifications for Crossroads Solar Crossroads Solar 380?

Official CEC datasheet figures for Crossroads Solar Crossroads Solar 380 (Mono-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for Crossroads Solar Crossroads Solar 380.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 380.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 350.5 W (92.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 49.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 9.9 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 40.64 V / 9.35 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.278 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 18.63% (2.04 m2) | Array roof footprint density |
| **Cell Count & Technology** | 12 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Crossroads Solar Crossroads Solar 380 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Crossroads Solar Crossroads Solar 380 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 16 | 6.08 kW | 351 sq ft | $1,522 | $2,573 |
| **8 kW Class** | 22 | 8.36 kW | 483 sq ft | $2,092 | $3,538 |
| **10 kW Class** | 27 | 10.26 kW | 593 sq ft | $2,568 | $4,342 |

## How Many Crossroads Solar Crossroads Solar 380 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Crossroads Solar Crossroads Solar 380 (53.77 V at 14 F).

Computed from Voc=49.0V and beta_Voc=-0.278%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 55.13 V | 10 panels | 551.3 V | 18 panels |
| **-10 C (14 F)** | 53.77 V | 11 panels | 591.5 V | 18 panels |
| **0 C (32 F)** | 52.41 V | 11 panels | 576.5 V | 19 panels |
| **25 C (77 F STC)** | 49.0 V | 12 panels | 588.0 V | 20 panels |

## Which Cross-Brand Solar Modules Compare Closest to Crossroads Solar Crossroads Solar 380?

Competing CEC solar panels closest to Crossroads Solar Crossroads Solar 380 in nameplate wattage and Voc, starting with Caterpillar Inc PVC380MP03H.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Caterpillar Inc PVC380MP03H**](https://epri-peac.com/solar-equipment/modules/caterpillar-inc/caterpillar-inc-pvc380mp03h/) Caterpillar Inc | 380.0 W | Tie (0 W) | 49.0 V | 19.63% | 94.1% |
| [**Caterpillar Inc PVC380MP03**](https://epri-peac.com/solar-equipment/modules/caterpillar-inc/caterpillar-inc-pvc380mp03/) Caterpillar Inc | 380.0 W | Tie (0 W) | 49.03 V | 20.21% | 93.5% |
| [**Bluesun Solar Energy Tech CoLtd BSM380M-72**](https://epri-peac.com/solar-equipment/modules/bluesun-solar-energy-tech-coltd/bluesun-solar-energy-tech-coltd-bsm380m-72/) Bluesun Solar Energy Tech CoLtd | 380.0 W | Tie (0 W) | 48.67 V | 19.59% | 92.0% |
| [**Auxin Solar AXN6M612T380**](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn6m612t380/) Auxin Solar | 380.0 W | Tie (0 W) | 47.94 V | 19.58% | 91.9% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Crossroads Solar Crossroads Solar 380?

Evaluate Crossroads Solar Crossroads Solar 380 (380.0 W STC, 49.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Crossroads Solar Crossroads Solar 380 reaches 55.13 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 22 panels for an 8 kW build require 483 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (483 sq ft).
- 2026 tax credit baseline: cash residential installs of Crossroads Solar Crossroads Solar 380 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Crossroads Solar Crossroads Solar 380 8 kW Residential Fit

Needs 22 modules (483 sq ft) with a 20 A string OCPD, offsetting ~$2,092/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Caterpillar Inc PVC380MP03H.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 350.5 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Crossroads Solar Crossroads Solar 380 by Crossroads Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Crossroads Solar Crossroads Solar 380?

Multiplying Crossroads Solar Crossroads Solar 380's 9.9 A short-circuit current by 1.56 equals 15.44 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

### Can Crossroads Solar Crossroads Solar 380 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 53.77 V cold Voc at 14 F and handles 9.9 A Isc; string inverters cap Crossroads Solar Crossroads Solar 380 at 11 panels on 600 V.

### Is Crossroads Solar Crossroads Solar 380 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Crossroads Solar Crossroads Solar 380 rely on utility bill offset (~$2,092/yr at 8 kW) rather than 25D.

## Related Pages

Compare Crossroads Solar equipment, Caterpillar Inc PVC380MP03H specs, utility payback rates, and NEC string calculators alongside Crossroads Solar Crossroads Solar 380.

[All Crossroads Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/crossroads-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Crossroads Solar

- [All Crossroads Solar Specs](https://epri-peac.com/solar-equipment/brands/crossroads-solar/)