title: "Chint New Energy Technology Co Specs (600.0W, 52.1V Voc)"
url: https://epri-peac.com/solar-equipment/modules/chint-new-energy-technology-co-ltd/chint-new-energy-technology-co-ltd-chsm72n-dg-f-bh-600/
description: "CEC datasheet for Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-600: 600.0W STC, 52.1V Voc, 14-panel 8kW sizing, and NEC 690.7 limits."
---

CEC PV Module

# Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-600 — CEC Solar Module Specifications

Manufacturer: [**Chint New Energy Technology Co Ltd**](https://epri-peac.com/solar-equipment/brands/chint-new-energy-technology-co-ltd/) Registry: **CEC Verified Engineering Specification**

Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-600 is a 600.0 W STC (568.6 W PTC) Mono-c-Si solar module ranking #1,320 of 21,677 CEC listings (top 6.7%; higher than 93.3% of peers). It delivers 23.26% efficiency, 52.1 V Voc at 25 C, and 56.28 V cold Voc at -10 C (10 panels max per 600 V string).

- **STC Wattage** : 600.0 W

- **PTC Wattage** : 568.6 W

- **Voc @ 25C** : 52.1 V

- **Efficiency** : 23.26%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-600 Compare Against Peer CEC Listings?

How Chint New Energy Technology Co Ltd Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-600 handles rooftop heat (568.6 W PTC), 8 kW sizing, and cold winter string voltage.

Chint New Energy Technology Co Ltd builds the Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-600 (Mono-c-Si) as a large-format commercial and ground-mount module delivering 232.6 W/m2 (3.35 percentage points above 19.91% CEC median). Compared against CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI FE72-18X(ND)-600 (600.0 W), this model holds strong 94.8% PTC-to-STC heat retention (#1,790 of 21,677). Higher 52.1 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C), while NEC 690.8 sets a 22.79 A overcurrent floor served by a 25 A breaker.

## Where Does Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-600 Fall Across Listed CEC Models?

Where Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-600 (600.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-600?

Percentile placement of Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-600 across power density (232.6 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-600?

Four critical engineering numbers homeowners and solar installers check first when reviewing Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-600 specifications.

Rank #1,320 / 21,677

### Top 6.7% STC Output

600.0 W STC (+215.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #770

### 23.26% Aperture Efficiency

Power density 232.6 W/m2 (3.35 percentage points above 19.91% CEC median). PTC/STC ratio: 94.8% (rank #1,790).

NEC 690.7 Limit

### 10 Panels Max @ -10 C (600 V)

Cold Voc reaches 56.28 V at -10 C (562.8 V string) and 57.47 V at -20 C (10 max).

 8 kW Reference Array

### 14 Panels = 8,400 W STC

Occupies 36.1 m2 (389 sq ft) producing 7,960 W PTC; NEC 690.8 OCPD floor is 22.79 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 52.1 * (1 + (-0.229/100) * (-10 - 25)) = 56.28 V | OCPD = 1.56 * 14.61 = 22.79 A

Inputs from CEC Modules.csv for Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-600: Voc=52.1 V, beta_Voc=-0.229%/C, Isc=14.61 A, STC=600.0 W, Area=2.58 m2.

**Result:** 10 panels max on 600 V (562.8 V); 14 panels for 8 kW (389 sq ft).

## What Are the Published CEC Specifications for Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-600?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-600.

Official California Energy Commission (NREL SAM) test parameters for Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-600.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 600.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 568.6 W (94.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 52.1 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 14.61 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 43.78 V / 13.7 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.229 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 23.26% (2.58 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Bifacial glass-glass |

## How Many Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-600 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-600 (600.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 10 | 6.0 kW | 278 sq ft | $1,502 | $2,539 |
| **8 kW Class** | 14 | 8.4 kW | 389 sq ft | $2,102 | $3,555 |
| **10 kW Class** | 17 | 10.2 kW | 472 sq ft | $2,553 | $4,317 |

## How Many Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-600 Modules Fit in a Cold-Weather String?

Maximum series module counts for Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-600 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=52.1V and beta_Voc=-0.229%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 57.47 V | 10 panels | 574.7 V | 17 panels |
| **-10 C (14 F)** | 56.28 V | 10 panels | 562.8 V | 17 panels |
| **0 C (32 F)** | 55.08 V | 10 panels | 550.8 V | 18 panels |
| **25 C (77 F STC)** | 52.1 V | 11 panels | 573.1 V | 19 panels |

## Which Cross-Brand Solar Modules Compare Closest to Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-600?

Alternative CEC solar modules from competing brands near Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-600 (600.0 W), including CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI FE72-18X(ND)-600.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI FE72-18X(ND)-600**](https://epri-peac.com/solar-equipment/modules/chen-gunes-enerjisi-sanayi-ve-ticaret-limited-sirketi/chen-gunes-enerjisi-sanayi-ve-ticaret-limited-sirketi-fe72-18x-nd-600/) CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI | 600.0 W | Tie (0 W) | 52.0 V | 23.44% | 94.2% |
| [**Mission Solar Energy LLC MSH10-600HN4G**](https://epri-peac.com/solar-equipment/modules/mission-solar-energy-llc/mission-solar-energy-llc-msh10-600hn4g/) Mission Solar Energy LLC | 600.0 W | Tie (0 W) | 52.0 V | 23.26% | 94.2% |
| [**Gautam Solar Pvt Ltd G2G1800-HAD**](https://epri-peac.com/solar-equipment/modules/gautam-solar-pvt-ltd/gautam-solar-pvt-ltd-g2g1800-had/) Gautam Solar Pvt Ltd | 600.0 W | Tie (0 W) | 51.64 V | 23.37% | 95.2% |
| [**Gautam Solar Pvt Ltd G2X1800N-UHAD**](https://epri-peac.com/solar-equipment/modules/gautam-solar-pvt-ltd/gautam-solar-pvt-ltd-g2x1800n-uhad/) Gautam Solar Pvt Ltd | 600.0 W | Tie (0 W) | 51.64 V | 23.35% | 95.0% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-600?

Evaluate Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-600 (600.0 W STC, 52.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-600 reaches 57.47 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 14 panels for an 8 kW build require 389 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-600 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-600 8 kW Residential Fit

Needs 14 modules (389 sq ft) with a 25 A string OCPD, offsetting ~$2,102/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI FE72-18X(ND)-600.

### Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 568.6 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-600 by Chint New Energy Technology Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-600?

Multiplying Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-600's 14.61 A short-circuit current by 1.56 equals 22.79 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

### Can Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-600 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 56.28 V cold Voc at 14 F and handles 14.61 A Isc; string inverters cap Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-600 at 10 panels on 600 V.

### Is Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-600 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-600 rely on utility bill offset (~$2,102/yr at 8 kW) rather than 25D.

## Related Pages

Compare Chint New Energy Technology Co Ltd equipment, CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI FE72-18X(ND)-600 specs, utility payback rates, and NEC string calculators alongside Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-600.

[All Chint New Energy Technology Co Ltd Certified Solar Models](https://epri-peac.com/solar-equipment/brands/chint-new-energy-technology-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Chint New Energy Technology Co Ltd

- [All Chint New Energy Technology Co Ltd Specs](https://epri-peac.com/solar-equipment/brands/chint-new-energy-technology-co-ltd/)
- [Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-735](https://epri-peac.com/solar-equipment/modules/chint-new-energy-technology-co-ltd/chint-new-energy-technology-co-ltd-chsm66n-dg-f-bh-735/)
- [Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-710](https://epri-peac.com/solar-equipment/modules/chint-new-energy-technology-co-ltd/chint-new-energy-technology-co-ltd-chsm66n-dg-f-bh-710/)
- [Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-685](https://epri-peac.com/solar-equipment/modules/chint-new-energy-technology-co-ltd/chint-new-energy-technology-co-ltd-chsm66n-dg-f-bh-685/)
- [Chint New Energy Technology Co Ltd CHSM66N-HC-685](https://epri-peac.com/solar-equipment/modules/chint-new-energy-technology-co-ltd/chint-new-energy-technology-co-ltd-chsm66n-hc-685/)