title: "Chinaland Solar Energy HSE295-72M Specs (295.0W, 44.4V Voc)"
url: https://epri-peac.com/solar-equipment/modules/chinaland-solar-energy/chinaland-solar-energy-hse295-72m/
description: "CEC datasheet for Chinaland Solar Energy HSE295-72M: 295.0W STC, 44.4V Voc, 28-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# Chinaland Solar Energy HSE295-72M — CEC Solar Module Specifications

Manufacturer: [**Chinaland Solar Energy**](https://epri-peac.com/solar-equipment/brands/chinaland-solar-energy/) Registry: **CEC Verified Engineering Specification**

Chinaland Solar Energy HSE295-72M is a 295.0 W STC (266.0 W PTC) Mono-c-Si solar module ranking #16,890 of 21,677 CEC listings (below all-CEC median; higher than 20.4% of peers). It delivers 15.28% efficiency, 44.4 V Voc at 25 C, and 49.76 V cold Voc at -10 C (12 panels max per 600 V string).

- **STC Wattage** : 295.0 W

- **PTC Wattage** : 266.0 W

- **Voc @ 25C** : 44.4 V

- **Efficiency** : 15.28%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Chinaland Solar Energy HSE295-72M Compare Against Peer CEC Listings?

Solar engineering breakdown for Chinaland Solar Energy HSE295-72M: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 5,889 Mono-c-Si listings from Chinaland Solar Energy and peers, Chinaland Solar Energy HSE295-72M stands 115.0 W below the 410.0 W Mono-c-Si median and typical 90.2% PTC-to-STC thermal output (266.0 W real-world rating). Sizing 6 kW (21 panels) to 10 kW (34 panels) yields $1,552-$2,510/yr in baseline US bill offset. Mid-range 44.4 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F.

## Where Does Chinaland Solar Energy HSE295-72M Fall Across Listed CEC Models?

Distribution marker showing Chinaland Solar Energy HSE295-72M (295.0 W) relative to the 385.0 W all-CEC solar panel median.

## What Dataset Percentiles Define Chinaland Solar Energy HSE295-72M?

Dataset percentiles tracking Chinaland Solar Energy HSE295-72M power output, thermal retention ratio, and aperture efficiency against 21,677 models.

## What Do the Dataset Ranks Show for Chinaland Solar Energy HSE295-72M?

Benchmark highlights for Chinaland Solar Energy HSE295-72M covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #16,890 / 21,677

### 295.0 W STC · Higher Than 20.4%

295.0 W STC (-90.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #19,278

### 15.28% Aperture Efficiency

Power density 152.8 W/m2 (4.63 percentage points below 19.91% CEC median). PTC/STC ratio: 90.2% (rank #18,532).

NEC 690.7 Limit

### 12 Panels Max @ -10 C (600 V)

Cold Voc reaches 49.76 V at -10 C (597.1 V string) and 51.29 V at -20 C (11 max).

 8 kW Reference Array

### 28 Panels = 8,260 W STC

Occupies 54.0 m2 (582 sq ft) producing 7,448 W PTC; NEC 690.8 OCPD floor is 13.49 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 44.4 * (1 + (-0.345/100) * (-10 - 25)) = 49.76 V | OCPD = 1.56 * 8.65 = 13.49 A

Inputs from CEC Modules.csv for Chinaland Solar Energy HSE295-72M: Voc=44.4 V, beta_Voc=-0.345%/C, Isc=8.65 A, STC=295.0 W, Area=1.93 m2.

**Result:** 12 panels max on 600 V (597.1 V); 28 panels for 8 kW (582 sq ft).

## What Are the Published CEC Specifications for Chinaland Solar Energy HSE295-72M?

Official CEC datasheet figures for Chinaland Solar Energy HSE295-72M (Mono-c-Si) used in utility interconnection and permit reviews. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Official California Energy Commission (NREL SAM) test parameters for Chinaland Solar Energy HSE295-72M.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 295.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 266.0 W (90.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 44.4 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.65 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 36.3 V / 8.13 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.345 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 15.28% (1.93 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Chinaland Solar Energy HSE295-72M Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Chinaland Solar Energy HSE295-72M modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 21 | 6.2 kW | 436 sq ft | $1,552 | $2,624 |
| **8 kW Class** | 28 | 8.26 kW | 582 sq ft | $2,067 | $3,496 |
| **10 kW Class** | 34 | 10.03 kW | 706 sq ft | $2,510 | $4,245 |

## How Many Chinaland Solar Energy HSE295-72M Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Chinaland Solar Energy HSE295-72M (49.76 V at 14 F).

Computed from Voc=44.4V and beta_Voc=-0.345%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 51.29 V | 11 panels | 564.2 V | 19 panels |
| **-10 C (14 F)** | 49.76 V | 12 panels | 597.1 V | 20 panels |
| **0 C (32 F)** | 48.23 V | 12 panels | 578.8 V | 20 panels |
| **25 C (77 F STC)** | 44.4 V | 13 panels | 577.2 V | 22 panels |

## Which Cross-Brand Solar Modules Compare Closest to Chinaland Solar Energy HSE295-72M?

Competing CEC solar panels closest to Chinaland Solar Energy HSE295-72M in nameplate wattage and Voc, starting with BYD Company Limited BYD295P6K-36.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**BYD Company Limited BYD295P6K-36**](https://epri-peac.com/solar-equipment/modules/byd-company-limited/byd-company-limited-byd295p6k-36/) BYD Company Limited | 295.0 W | Tie (0 W) | 44.9 V | 15.21% | 91.5% |
| [**Centrosolar America TP7 295xx**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-tp7-295xx/) Centrosolar America | 295.0 W | Tie (0 W) | 45.1 V | 15.13% | 90.4% |
| [**Centrosolar America TP7S 295xx**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-tp7s-295xx/) Centrosolar America | 295.0 W | Tie (0 W) | 45.1 V | 15.13% | 90.4% |
| [**Centrosolar America DM72 290**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-dm72-290/) Centrosolar America | 290.0 W | -5.0 W | 44.4 V | 14.92% | 90.6% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Chinaland Solar Energy HSE295-72M?

Evaluate Chinaland Solar Energy HSE295-72M (295.0 W STC, 44.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Chinaland Solar Energy HSE295-72M reaches 51.29 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 28 panels for an 8 kW build require 582 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (582 sq ft).
- 2026 tax credit baseline: cash residential installs of Chinaland Solar Energy HSE295-72M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Chinaland Solar Energy HSE295-72M 8 kW Residential Fit

Needs 28 modules (582 sq ft) with a 15 A string OCPD, offsetting ~$2,067/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare BYD Company Limited BYD295P6K-36.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 266.0 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Chinaland Solar Energy HSE295-72M by Chinaland Solar Energy grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Chinaland Solar Energy HSE295-72M?

Multiplying Chinaland Solar Energy HSE295-72M's 8.65 A short-circuit current by 1.56 equals 13.49 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

### Can Chinaland Solar Energy HSE295-72M pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 49.76 V cold Voc at 14 F and handles 8.65 A Isc; string inverters cap Chinaland Solar Energy HSE295-72M at 12 panels on 600 V.

### Is Chinaland Solar Energy HSE295-72M eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Chinaland Solar Energy HSE295-72M rely on utility bill offset (~$2,067/yr at 8 kW) rather than 25D.

## Related Pages

Compare Chinaland Solar Energy equipment, BYD Company Limited BYD295P6K-36 specs, utility payback rates, and NEC string calculators alongside Chinaland Solar Energy HSE295-72M.

[All Chinaland Solar Energy Certified Solar Models](https://epri-peac.com/solar-equipment/brands/chinaland-solar-energy/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Chinaland Solar Energy

- [All Chinaland Solar Energy Specs](https://epri-peac.com/solar-equipment/brands/chinaland-solar-energy/)
- [Chinaland Solar Energy HSE325-72M](https://epri-peac.com/solar-equipment/modules/chinaland-solar-energy/chinaland-solar-energy-hse325-72m/)
- [Chinaland Solar Energy HSE310-72M](https://epri-peac.com/solar-equipment/modules/chinaland-solar-energy/chinaland-solar-energy-hse310-72m/)
- [Chinaland Solar Energy HSE310-72P](https://epri-peac.com/solar-equipment/modules/chinaland-solar-energy/chinaland-solar-energy-hse310-72p/)
- [Chinaland Solar Energy HSE295-72P](https://epri-peac.com/solar-equipment/modules/chinaland-solar-energy/chinaland-solar-energy-hse295-72p/)
- [Chinaland Solar Energy HSE275-60M-B](https://epri-peac.com/solar-equipment/modules/chinaland-solar-energy/chinaland-solar-energy-hse275-60m-b/)