CEC PV Module

# Chinaland Solar Energy HSE240-60P — CEC Solar Module Specifications

Manufacturer: [**Chinaland Solar Energy**](https://epri-peac.com/solar-equipment/brands/chinaland-solar-energy/) Registry: **CEC Verified Engineering Specification**

Chinaland Solar Energy HSE240-60P is a 240.0 W STC (212.1 W PTC) Multi-c-Si solar module ranking #20,160 of 21,677 CEC listings (below all-CEC median; higher than 6.1% of peers). It delivers 14.78% efficiency, 35.7 V Voc at 25 C, and 40.26 V cold Voc at -10 C (14 panels max per 600 V string).

- **STC Wattage** : 240.0 W

- **PTC Wattage** : 212.1 W

- **Voc @ 25C** : 35.7 V

- **Efficiency** : 14.78%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Chinaland Solar Energy HSE240-60P Compare Against Peer CEC Listings?

How Chinaland Solar Energy Chinaland Solar Energy HSE240-60P handles rooftop heat (212.1 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Chinaland Solar Energy HSE240-60P exhibits 8.57 A short-circuit current, requiring a 13.37 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #20,160 of 21,677 (38.8 W below the 278.8 W Multi-c-Si median), this compact residential or specialty off-grid module covers 55.2 m2 for an 8 kW system (42 panels for 10 kW). Lower 35.7 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.

## Where Does Chinaland Solar Energy HSE240-60P Fall Across Listed CEC Models?

Where Chinaland Solar Energy HSE240-60P (240.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Chinaland Solar Energy HSE240-60P?

Percentile placement of Chinaland Solar Energy HSE240-60P across power density (147.8 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for Chinaland Solar Energy HSE240-60P?

Four critical engineering numbers homeowners and solar installers check first when reviewing Chinaland Solar Energy HSE240-60P specifications. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Rank #20,160 / 21,677

### 240.0 W STC · Higher Than 6.1%

240.0 W STC (-145.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #20,054

### 14.78% Aperture Efficiency

Power density 147.8 W/m2 (5.13 percentage points below 19.91% CEC median). PTC/STC ratio: 88.4% (rank #21,190).

NEC 690.7 Limit

### 14 Panels Max @ -10 C (600 V)

Cold Voc reaches 40.26 V at -10 C (563.6 V string) and 41.56 V at -20 C (14 max).

 8 kW Reference Array

### 34 Panels = 8,160 W STC

Occupies 55.2 m2 (594 sq ft) producing 7,211 W PTC; NEC 690.8 OCPD floor is 13.37 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 35.7 * (1 + (-0.365/100) * (-10 - 25)) = 40.26 V | OCPD = 1.56 * 8.57 = 13.37 A

Inputs from CEC Modules.csv for Chinaland Solar Energy HSE240-60P: Voc=35.7 V, beta_Voc=-0.365%/C, Isc=8.57 A, STC=240.0 W, Area=1.624 m2.

**Result:** 14 panels max on 600 V (563.6 V); 34 panels for 8 kW (594 sq ft).

## What Are the Published CEC Specifications for Chinaland Solar Energy HSE240-60P?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Chinaland Solar Energy HSE240-60P.

Official California Energy Commission (NREL SAM) test parameters for Chinaland Solar Energy HSE240-60P.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 240.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 212.1 W (88.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 35.7 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.57 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 30.0 V / 8.0 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.365 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 14.78% (1.624 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Multi-c-Si) | Monofacial backsheet |

## How Many Chinaland Solar Energy HSE240-60P Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Chinaland Solar Energy HSE240-60P (240.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 25 | 6.0 kW | 437 sq ft | $1,502 | $2,539 |
| **8 kW Class** | 34 | 8.16 kW | 594 sq ft | $2,042 | $3,454 |
| **10 kW Class** | 42 | 10.08 kW | 734 sq ft | $2,523 | $4,266 |

## Which Sibling Wattage & Trim Variants Belong to This Chinaland Solar Energy Series?

All closely matched Chinaland Solar Energy wattages and cosmetic trims sharing the Chinaland Solar Energy HSE240-60P architecture. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Sibling CEC listings grouped into the Chinaland Solar Energy HSE240-60P wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Chinaland Solar Energy HSE235-60P** | 235.0 W | 207.5 W | 35.6 V | 29.8 V | 14.47% |
| **Chinaland Solar Energy HSE240-60P** | 240.0 W | 212.1 W | 35.7 V | 30.0 V | 14.78% |
| **Chinaland Solar Energy HSE245-60P** | 245.0 W | 216.6 W | 36.1 V | 30.4 V | 15.09% |

## How Many Chinaland Solar Energy HSE240-60P Modules Fit in a Cold-Weather String?

Maximum series module counts for Chinaland Solar Energy HSE240-60P from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=35.7V and beta_Voc=-0.365%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 41.56 V | 14 panels | 581.8 V | 24 panels |
| **-10 C (14 F)** | 40.26 V | 14 panels | 563.6 V | 24 panels |
| **0 C (32 F)** | 38.96 V | 15 panels | 584.4 V | 25 panels |
| **25 C (77 F STC)** | 35.7 V | 16 panels | 571.2 V | 28 panels |

## Which Cross-Brand Solar Modules Compare Closest to Chinaland Solar Energy HSE240-60P?

Alternative CEC solar modules from competing brands near Chinaland Solar Energy HSE240-60P (240.0 W), including Centrosolar America DM60 240.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Centrosolar America DM60 240**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-dm60-240/) Centrosolar America | 240.0 W | Tie (0 W) | 36.8 V | 14.64% | 90.6% |
| [**Heliene 60M240**](https://epri-peac.com/solar-equipment/modules/heliene/heliene-60m240/) Heliene | 240.0 W | Tie (0 W) | 36.8 V | 14.43% | 90.1% |
| [**Eoplly New Energy Technology EP156M/60-240S AC**](https://epri-peac.com/solar-equipment/modules/eoplly-new-energy-technology/eoplly-new-energy-technology-ep156m-60-240s-ac/) Eoplly New Energy Technology | 240.0 W | Tie (0 W) | 36.9 V | 14.83% | 89.7% |
| [**Eoplly New Energy Technology EP156MB/60-240S AC**](https://epri-peac.com/solar-equipment/modules/eoplly-new-energy-technology/eoplly-new-energy-technology-ep156mb-60-240s-ac/) Eoplly New Energy Technology | 240.0 W | Tie (0 W) | 36.9 V | 14.83% | 89.5% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Chinaland Solar Energy HSE240-60P?

Evaluate Chinaland Solar Energy HSE240-60P (240.0 W STC, 35.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Chinaland Solar Energy HSE240-60P reaches 41.56 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 34 panels for an 8 kW build require 594 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 34 panels (594 sq ft).
- 2026 tax credit baseline: cash residential installs of Chinaland Solar Energy HSE240-60P carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Chinaland Solar Energy HSE240-60P 8 kW Residential Fit

Needs 34 modules (594 sq ft) with a 15 A string OCPD, offsetting ~$2,042/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Centrosolar America DM60 240.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 212.1 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Chinaland Solar Energy HSE240-60P by Chinaland Solar Energy grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is Chinaland Solar Energy HSE240-60P PTC wattage (212.1 W) lower than STC (240.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 212.1 W PTC (88.4% retention) across Chinaland Solar Energy HSE240-60P's 1.624 m2 aperture.

### Who should skip Chinaland Solar Energy HSE240-60P on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 34 Chinaland Solar Energy HSE240-60P panels (594 sq ft) leave unusable roof gaps vs. Centrosolar America DM60 240.

### What is the 1,000 V commercial string limit for Chinaland Solar Energy HSE240-60P?

On 1,000 V commercial inverters at -10 C (40.26 V cold Voc), Chinaland Solar Energy HSE240-60P fits up to 24 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Chinaland Solar Energy HSE240-60P.

## Related Pages

Compare Chinaland Solar Energy equipment, Centrosolar America DM60 240 specs, utility payback rates, and NEC string calculators alongside Chinaland Solar Energy HSE240-60P.

[All Chinaland Solar Energy Certified Solar Models](https://epri-peac.com/solar-equipment/brands/chinaland-solar-energy/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Chinaland Solar Energy

- [All Chinaland Solar Energy Specs](https://epri-peac.com/solar-equipment/brands/chinaland-solar-energy/)
- [Chinaland Solar Energy HSE325-72M](https://epri-peac.com/solar-equipment/modules/chinaland-solar-energy/chinaland-solar-energy-hse325-72m/)
- [Chinaland Solar Energy HSE310-72M](https://epri-peac.com/solar-equipment/modules/chinaland-solar-energy/chinaland-solar-energy-hse310-72m/)
- [Chinaland Solar Energy HSE310-72P](https://epri-peac.com/solar-equipment/modules/chinaland-solar-energy/chinaland-solar-energy-hse310-72p/)
- [Chinaland Solar Energy HSE295-72M](https://epri-peac.com/solar-equipment/modules/chinaland-solar-energy/chinaland-solar-energy-hse295-72m/)
- [Chinaland Solar Energy HSE295-72P](https://epri-peac.com/solar-equipment/modules/chinaland-solar-energy/chinaland-solar-energy-hse295-72p/)