CertainTeed Apollo II - 75x is a 75.0 W STC (64.2 W PTC) Mono-c-Si solar module ranking #21,614 of 21,677 CEC listings (below all-CEC median; higher than 0.3% of peers). It delivers 14.15% efficiency, 9.92 V Voc at 25 C, and 10.87 V cold Voc at -10 C (55 panels max per 600 V string).

- **STC Wattage** : 75.0 W

- **PTC Wattage** : 64.2 W

- **Voc @ 25C** : 9.92 V

- **Efficiency** : 14.15%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does CertainTeed Apollo II - 75x Compare Against Peer CEC Listings?

Engineering position of CertainTeed Apollo II - 75x (75.0 W STC) vs. Merlin Solar Technologies Inc Solstice Shingle 72W-01 across 5,889 CEC Mono-c-Si solar modules.

Built with 14 Mono-c-Si cells, CertainTeed Apollo II - 75x pairs typical 85.6% PTC-to-STC thermal output (64.2 W real-world rating) with 9.92 V nominal Voc. An 8 kW residential build (8,025 W DC, 6,869 W PTC) saves ~$2,010/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Merlin Solar Technologies Inc Solstice Shingle 72W-01 offers a 72.0 W alternative.

## Where Does CertainTeed Apollo II - 75x Fall Across Listed CEC Models?

Plots CertainTeed Apollo II - 75x at 75.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

## What Dataset Percentiles Define CertainTeed Apollo II - 75x?

Benchmarks CertainTeed Apollo II - 75x on STC wattage, thermal PTC/STC retention, and 14.15 aperture conversion efficiency against CEC peers.

## What Do the Dataset Ranks Show for CertainTeed Apollo II - 75x?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for CertainTeed Apollo II - 75x by CertainTeed.

Rank #21,614 / 21,677

### 75.0 W STC · Higher Than 0.3%

75.0 W STC (-310.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #20,771

### 14.15% Aperture Efficiency

Power density 141.5 W/m2 (5.76 percentage points below 19.91% CEC median). PTC/STC ratio: 85.6% (rank #21,656).

NEC 690.7 Limit

### 55 Panels Max @ -10 C (600 V)

Cold Voc reaches 10.87 V at -10 C (597.8 V string) and 11.14 V at -20 C (53 max).

 8 kW Reference Array

### 107 Panels = 8,025 W STC

Occupies 56.7 m2 (610 sq ft) producing 6,869 W PTC; NEC 690.8 OCPD floor is 15.01 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 9.92 * (1 + (-0.273/100) * (-10 - 25)) = 10.87 V | OCPD = 1.56 * 9.62 = 15.01 A

Inputs from CEC Modules.csv for CertainTeed Apollo II - 75x: Voc=9.92 V, beta_Voc=-0.273%/C, Isc=9.62 A, STC=75.0 W, Area=0.53 m2.

**Result:** 55 panels max on 600 V (597.8 V); 107 panels for 8 kW (610 sq ft).

## What Are the Published CEC Specifications for CertainTeed Apollo II - 75x?

Laboratory test ratings recorded for CertainTeed Apollo II - 75x (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for CertainTeed Apollo II - 75x.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 75.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 64.2 W (85.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 9.92 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 9.62 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 8.06 V / 9.33 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.273 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 14.15% (0.53 m2) | Array roof footprint density |
| **Cell Count & Technology** | 14 cells (Mono-c-Si) | Monofacial backsheet |

## How Many CertainTeed Apollo II - 75x Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (610 sq ft at 8 kW), and estimated Year-1 electric bill offset for CertainTeed Apollo II - 75x.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 80 | 6.0 kW | 456 sq ft | $1,502 | $2,539 |
| **8 kW Class** | 107 | 8.03 kW | 610 sq ft | $2,010 | $3,398 |
| **10 kW Class** | 134 | 10.05 kW | 764 sq ft | $2,515 | $4,253 |

## How Many CertainTeed Apollo II - 75x Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for CertainTeed Apollo II - 75x (beta_Voc -0.273%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=9.92V and beta_Voc=-0.273%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 11.14 V | 53 panels | 590.4 V | 89 panels |
| **-10 C (14 F)** | 10.87 V | 55 panels | 597.8 V | 91 panels |
| **0 C (32 F)** | 10.6 V | 56 panels | 593.6 V | 94 panels |
| **25 C (77 F STC)** | 9.92 V | 60 panels | 595.2 V | 100 panels |

## Which Cross-Brand Solar Modules Compare Closest to CertainTeed Apollo II - 75x?

Closest cross-brand CEC competitors to CertainTeed Apollo II - 75x matched near 75.0 W STC and 9.92 V Voc, led by Merlin Solar Technologies Inc Solstice Shingle 72W-01.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Merlin Solar Technologies Inc Solstice Shingle 72W-01**](https://epri-peac.com/solar-equipment/modules/merlin-solar-technologies-inc/merlin-solar-technologies-inc-solstice-shingle-72w-01/) Merlin Solar Technologies Inc | 72.0 W | -3.0 W | 9.65 V | 13.58% | 89.4% |
| [**Merlin Solar Technologies Inc Solstice Shingle 70W-01**](https://epri-peac.com/solar-equipment/modules/merlin-solar-technologies-inc/merlin-solar-technologies-inc-solstice-shingle-70w-01/) Merlin Solar Technologies Inc | 70.0 W | -5.0 W | 9.51 V | 13.21% | 89.4% |
| [**LUMA Resources LRSS**](https://epri-peac.com/solar-equipment/modules/luma-resources/luma-resources-lrss/) LUMA Resources | 80.0 W | +5.0 W | 10.43 V | 16.0% | 90.0% |
| [**Arka Energy Inc AEP-821-00012-A**](https://epri-peac.com/solar-equipment/modules/arka-energy-inc/arka-energy-inc-aep-821-00012-a/) Arka Energy Inc | 77.0 W | +2.0 W | 11.56 V | 14.81% | 92.1% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for CertainTeed Apollo II - 75x?

Evaluate CertainTeed Apollo II - 75x (75.0 W STC, 9.92 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), CertainTeed Apollo II - 75x reaches 11.14 V per panel—exceeding 53 panels in series voids 600 V inverter warranties.
- Footprint constraint: 107 panels for an 8 kW build require 610 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 107 panels (610 sq ft).
- 2026 tax credit baseline: cash residential installs of CertainTeed Apollo II - 75x carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### CertainTeed Apollo II - 75x 8 kW Residential Fit

Needs 107 modules (610 sq ft) with a 20 A string OCPD, offsetting ~$2,010/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 55 panels (-10 C) or 53 panels (-20 C), or compare Merlin Solar Technologies Inc Solstice Shingle 72W-01.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 64.2 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for CertainTeed Apollo II - 75x by CertainTeed grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for CertainTeed Apollo II - 75x?

Multiplying CertainTeed Apollo II - 75x's 9.62 A short-circuit current by 1.56 equals 15.01 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

### Can CertainTeed Apollo II - 75x pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 10.87 V cold Voc at 14 F and handles 9.62 A Isc; string inverters cap CertainTeed Apollo II - 75x at 55 panels on 600 V.

### Is CertainTeed Apollo II - 75x eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of CertainTeed Apollo II - 75x rely on utility bill offset (~$2,010/yr at 8 kW) rather than 25D.

## Related Pages

Compare CertainTeed equipment, Merlin Solar Technologies Inc Solstice Shingle 72W-01 specs, utility payback rates, and NEC string calculators alongside CertainTeed Apollo II - 75x.

[All CertainTeed Certified Solar Models](https://epri-peac.com/solar-equipment/brands/certainteed/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From CertainTeed

- [All CertainTeed Specs](https://epri-peac.com/solar-equipment/brands/certainteed/)
- [CertainTeed CTM10455HC11-06](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-ctm10455hc11-06/)
- [CertainTeed CTTC455HC12-08](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-cttc455hc12-08/)
- [CertainTeed CTM10450HC11-06](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-ctm10450hc11-06/)
- [CertainTeed CTM10445HC11-06](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-ctm10445hc11-06/)
- [CertainTeed CTM10440HC11-06](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-ctm10440hc11-06/)