title: "CertainTeed Apollo II - 74x Specs (74.0W, 9.86V Voc)"
url: https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-apollo-ii-74x/
description: "CEC datasheet for CertainTeed Apollo II - 74x: 74.0W STC, 9.86V Voc, 109-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# CertainTeed Apollo II - 74x — CEC Solar Module Specifications

Manufacturer: [**CertainTeed**](https://epri-peac.com/solar-equipment/brands/certainteed/) Registry: **CEC Verified Engineering Specification**

CertainTeed Apollo II - 74x is a 74.0 W STC (63.3 W PTC) Mono-c-Si solar module ranking #21,621 of 21,677 CEC listings (below all-CEC median; higher than 0.3% of peers). It delivers 13.96% efficiency, 9.86 V Voc at 25 C, and 10.8 V cold Voc at -10 C (55 panels max per 600 V string).

- **STC Wattage** : 74.0 W

- **PTC Wattage** : 63.3 W

- **Voc @ 25C** : 9.86 V

- **Efficiency** : 13.96%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does CertainTeed Apollo II - 74x Compare Against Peer CEC Listings?

Solar engineering breakdown for CertainTeed Apollo II - 74x: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 74.0 W STC and 63.3 W PTC, CertainTeed Apollo II - 74x sits -311.0 W vs all-CEC median (below all-CEC median; higher than 0.3% of peers) among 21,677 listed modules. Power density reaches 139.6 W/m2 (5.95 percentage points below 19.91% CEC median). Lower 9.86 V string voltage fits 55 panels in series at 14 F and pairs easily with microinverters, whereas 1,000 V commercial inverters handle up to 92 panels in series. Alternative peer Merlin Solar Technologies Inc Solstice Shingle 72W-01 rates 72.0 W.

## Where Does CertainTeed Apollo II - 74x Fall Across Listed CEC Models?

Distribution marker showing CertainTeed Apollo II - 74x (74.0 W) relative to the 385.0 W all-CEC solar panel median.

## What Dataset Percentiles Define CertainTeed Apollo II - 74x?

Dataset percentiles tracking CertainTeed Apollo II - 74x power output, thermal retention ratio, and aperture efficiency against 21,677 models.

## What Do the Dataset Ranks Show for CertainTeed Apollo II - 74x?

Benchmark highlights for CertainTeed Apollo II - 74x covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #21,621 / 21,677

### 74.0 W STC · Higher Than 0.3%

74.0 W STC (-311.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #20,928

### 13.96% Aperture Efficiency

Power density 139.6 W/m2 (5.95 percentage points below 19.91% CEC median). PTC/STC ratio: 85.5% (rank #21,659).

NEC 690.7 Limit

### 55 Panels Max @ -10 C (600 V)

Cold Voc reaches 10.8 V at -10 C (594.0 V string) and 11.07 V at -20 C (54 max).

 8 kW Reference Array

### 109 Panels = 8,066 W STC

Occupies 57.8 m2 (622 sq ft) producing 6,900 W PTC; NEC 690.8 OCPD floor is 14.94 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 9.86 * (1 + (-0.273/100) * (-10 - 25)) = 10.8 V | OCPD = 1.56 * 9.58 = 14.94 A

Inputs from CEC Modules.csv for CertainTeed Apollo II - 74x: Voc=9.86 V, beta_Voc=-0.273%/C, Isc=9.58 A, STC=74.0 W, Area=0.53 m2.

**Result:** 55 panels max on 600 V (594.0 V); 109 panels for 8 kW (622 sq ft).

## What Are the Published CEC Specifications for CertainTeed Apollo II - 74x?

Official CEC datasheet figures for CertainTeed Apollo II - 74x (Mono-c-Si) used in utility interconnection and permit reviews. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Official California Energy Commission (NREL SAM) test parameters for CertainTeed Apollo II - 74x.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 74.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 63.3 W (85.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 9.86 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 9.58 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 8.01 V / 9.27 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.273 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 13.96% (0.53 m2) | Array roof footprint density |
| **Cell Count & Technology** | 14 cells (Mono-c-Si) | Monofacial backsheet |

## How Many CertainTeed Apollo II - 74x Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many CertainTeed Apollo II - 74x modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 82 | 6.07 kW | 468 sq ft | $1,519 | $2,569 |
| **8 kW Class** | 109 | 8.07 kW | 622 sq ft | $2,020 | $3,415 |
| **10 kW Class** | 136 | 10.06 kW | 776 sq ft | $2,518 | $4,258 |

## How Many CertainTeed Apollo II - 74x Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on CertainTeed Apollo II - 74x (10.8 V at 14 F).

Computed from Voc=9.86V and beta_Voc=-0.273%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 11.07 V | 54 panels | 597.8 V | 90 panels |
| **-10 C (14 F)** | 10.8 V | 55 panels | 594.0 V | 92 panels |
| **0 C (32 F)** | 10.53 V | 56 panels | 589.7 V | 94 panels |
| **25 C (77 F STC)** | 9.86 V | 60 panels | 591.6 V | 101 panels |

## Which Cross-Brand Solar Modules Compare Closest to CertainTeed Apollo II - 74x?

Competing CEC solar panels closest to CertainTeed Apollo II - 74x in nameplate wattage and Voc, starting with Merlin Solar Technologies Inc Solstice Shingle 72W-01.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Merlin Solar Technologies Inc Solstice Shingle 72W-01**](https://epri-peac.com/solar-equipment/modules/merlin-solar-technologies-inc/merlin-solar-technologies-inc-solstice-shingle-72w-01/) Merlin Solar Technologies Inc | 72.0 W | -2.0 W | 9.65 V | 13.58% | 89.4% |
| [**Merlin Solar Technologies Inc Solstice Shingle 70W-01**](https://epri-peac.com/solar-equipment/modules/merlin-solar-technologies-inc/merlin-solar-technologies-inc-solstice-shingle-70w-01/) Merlin Solar Technologies Inc | 70.0 W | -4.0 W | 9.51 V | 13.21% | 89.4% |
| [**Merlin Solar Technologies Inc Solstice Shingle 68W-01**](https://epri-peac.com/solar-equipment/modules/merlin-solar-technologies-inc/merlin-solar-technologies-inc-solstice-shingle-68w-01/) Merlin Solar Technologies Inc | 68.0 W | -6.0 W | 9.37 V | 12.83% | 89.4% |
| [**LUMA Resources LRSS**](https://epri-peac.com/solar-equipment/modules/luma-resources/luma-resources-lrss/) LUMA Resources | 80.0 W | +6.0 W | 10.43 V | 16.0% | 90.0% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for CertainTeed Apollo II - 74x?

Evaluate CertainTeed Apollo II - 74x (74.0 W STC, 9.86 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), CertainTeed Apollo II - 74x reaches 11.07 V per panel—exceeding 54 panels in series voids 600 V inverter warranties.
- Footprint constraint: 109 panels for an 8 kW build require 622 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 109 panels (622 sq ft).
- 2026 tax credit baseline: cash residential installs of CertainTeed Apollo II - 74x carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### CertainTeed Apollo II - 74x 8 kW Residential Fit

Needs 109 modules (622 sq ft) with a 15 A string OCPD, offsetting ~$2,020/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 55 panels (-10 C) or 54 panels (-20 C), or compare Merlin Solar Technologies Inc Solstice Shingle 72W-01.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 63.3 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for CertainTeed Apollo II - 74x by CertainTeed grounded in CEC test data and NEC 690.7/690.8 limits.

### How many CertainTeed Apollo II - 74x panels fit on a 600 V winter solar string?

At -10 C (14 F), CertainTeed Apollo II - 74x cold Voc rises from 9.86 V to 10.8 V (beta_Voc -0.273%/C), capping a 600 V string at 55 panels (594.0 V).

### How much roof area does an 8 kW array of CertainTeed Apollo II - 74x need?

An 8 kW DC system uses 109 CertainTeed Apollo II - 74x modules (8,066 W STC / 6,900 W PTC), covering roughly 622 sq ft and saving ~$2,020/yr at 18.54 c/kWh.

### How does CertainTeed Apollo II - 74x compare against Merlin Solar Technologies Inc Solstice Shingle 72W-01?

CertainTeed Apollo II - 74x outputs 74.0 W STC (9.86 V Voc, rank #21,621 of 21,677), while Merlin Solar Technologies Inc Solstice Shingle 72W-01 delivers 72.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare CertainTeed equipment, Merlin Solar Technologies Inc Solstice Shingle 72W-01 specs, utility payback rates, and NEC string calculators alongside CertainTeed Apollo II - 74x.

[All CertainTeed Certified Solar Models](https://epri-peac.com/solar-equipment/brands/certainteed/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From CertainTeed

- [All CertainTeed Specs](https://epri-peac.com/solar-equipment/brands/certainteed/)
- [CertainTeed CTM10455HC11-06](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-ctm10455hc11-06/)
- [CertainTeed CTTC455HC12-08](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-cttc455hc12-08/)
- [CertainTeed CTM10450HC11-06](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-ctm10450hc11-06/)
- [CertainTeed CTM10445HC11-06](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-ctm10445hc11-06/)
- [CertainTeed CTM10440HC11-06](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-ctm10440hc11-06/)